510(k) Report

510(k) · Cleared

Cleared

Medip Pro

K191026510(k) TraditionalCleared Nov 7, 2019203-day reviewClass II21 CFR 892.2050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Medical IP Co., Ltd. · LLZ System, Image Processing, Radiological

Cleared on Nov 7, 2019 as substantially equivalent to K173619 (Materialise NV, 2018) after a 203-day review. Its family tree reaches back 5 generations to 1993. 2 later devices descend from it.

Decided
Nov 7, 2019
Review
203 days
Class
Class II
Product code
LLZ
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to K924630 (1993). 6 ancestors in all, the oldest K924810 (1993). 2 later devices descend from it, 1 citing it directly.

Other ancestors, by generationDescendants, by generation 4 generations back: 1 other ancestor 1 generation forward: 1 descendant2 generations forward: 1 descendant K173619 · Mimics inPrint · Materialise NV · 2018K073468 · Mimics · Materialise NV · 2008K033849 · Simplant System · Materialise NV · 2004K970617 · CT-Modeller System · Materialise NV · 1997K924630 · Surgicad (TM) View (TM) · Surgicad Corp. · 1993−50
  1. Root · 5 generations backK924630 Surgicad (TM) View (TM)Surgicad Corp. · 1993
  2. 4 generations backK970617 CT-Modeller SystemMaterialise NV · 1997
  3. 3 generations backK033849 Simplant SystemMaterialise NV · 2004
  4. 2 generations backK073468 MimicsMaterialise NV · 2008
  5. 1 generation backK173619 Mimics inPrintMaterialise NV · 2018
  6. This deviceK191026 Medip ProMedical IP Co., Ltd. · 2019
  7. Descendant · cites it directly · 1 of its ownK223556 DeepCatchMedical IP Co., Ltd. · 2023
  8. Descendant · 2 generations on · 0 of its ownK253944 Data Analysis Facilitation Suite (DAFS)Voronoi Health Analytics Incorporated · 2026

Most influential descendants

Showing 2 of 2 · See all
  • K223556DeepCatchMedical IP Co., Ltd. · 2023 · cites it directly1descendant
  • K253944Data Analysis Facilitation Suite (DAFS)Voronoi Health Analytics Incorporated · 2026 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K924630Surgicad (TM) View (TM)Surgicad Corp.1993—
−4K970617CT-Modeller SystemMaterialise NV1997—
−3K033849Simplant SystemMaterialise NV2004—
−2K073468MimicsMaterialise NV2008—
−1K173619Mimics inPrintMaterialise NV2018—
0 (this device)K191026Medip ProMedical IP Co., Ltd.2019—
+1K223556DeepCatchMedical IP Co., Ltd.2023—
+2K253944Data Analysis Facilitation Suite (DAFS)Voronoi Health Analytics Incorporated2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199310

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202310
202610
FIG. 1 — Lineage of K191026, 1993–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LLZ device

  1. #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K173619Mimics inPrint
Summary page 5
…Device(s) [21 CFR 807.92(a)(3)] The identified predicate devices within this submission are shown as follow: Predicate device - 510(k) Number: K173619 - Applicant: Materialise N.V. - Classification Name: System, Image processing, Radiological…
Materialise NV2018—
†K161841D2P3D Systems, Inc.2017—

Also cleared against K173619: 3 other devices →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K223556DeepCatchMedical IP Co., Ltd.20231

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 26 years and passes through 3 companies; a new generation was cleared every 4.0 years on median.
  • None of the 6 ancestors has a recall.
  • Of its descendants, K223556 (Medical IP Co., Ltd., 2023) has gone furthest, with 1 descendant of its own.
  • 3 other devices also cite its predicate K173619.

How does its category compare?

All LLZ devices

LLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.

FDA decisions per year · LLZ

58in 2025

2007: 762008: 942009: 702010: 512011: 1062012: 822013: 952014: 782015: 642016: 822017: 782018: 1042019: 742020: 812021: 832022: 652023: 872024: 622025: 582026 (partial year): 45
2007high 106 (2011) · low 51 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LLZ

173in 2025

2007: 36 days median2008: 52 days median2009: 62 days median2010: 98 days median2011: 79 days median2012: 87 days median2013: 84 days median2014: 89 days median2015: 90 days median2016: 90 days median2017: 107 days median2018: 105 days median2019: 107 days median2020: 115 days median2021: 116 days median2022: 137 days median2023: 157 days median2024: 131 days median2025: 173 days median2026 (partial year): 110 days median
2007high 173 (2025) · low 36 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LLZ

11in 2025

2007: 202008: 322009: 212010: 172011: 302012: 122013: 642014: 62015: 162016: 122017: 52018: 72019: 22020: 62021: 32022: 42023: 82024: 62025: 112026 (partial year): 14
2007high 64 (2013) · low 2 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LLZ

116in 2025

2007: 1522008: 1542009: 1452010: 1452011: 4542012: 2662013: 1,1302014: 15,6312015: 2112016: 2902017: 1042018: 722019: 882020: 822021: 702022: 282023: 262024: 422025: 116
2007high 15,631 (2014) · low 26 (2023)2025

MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007763620152
2008945232154
2009706221145
2010519817145
20111067930454
2012828712266
20139584641,130
20147889615,631
2015649016211
2016829012290
2017781075104
2018104105772
201974107288
202081115682
202183116370
202265137428
202387157826
202462131642
20255817311116
20264511014—

What is it indicated for?

MEDIP PRO is intended for use as a software interface and image segmentation system for the transfer of DICOM imaging information from a medical scanner to an output file. It is also used as pre-operative software for treatment planning.

The 3D printed models generated from the output file are meant for non-diagnostic use. MEDIP PRO should be used in conjunction with other diagnostic tools and expert clinical judgement.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K191026: Medip Pro.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K191026

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026