510(k) Report

510(k) · Cleared

Recalled · Class II · 2019

Monarch Endoscopy Platform (Monarch Platform)

K173760510(k) TraditionalCleared Mar 22, 2018101-day reviewClass II21 CFR 874.4680Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Auris Surgical Robotics, Inc. · EOQ Bronchoscope (Flexible Or Rigid)

Cleared on Mar 22, 2018 as substantially equivalent to K071530 (KARL STORZ Endoscopy-America, Inc., 2007) and 3 other predicates after a 101-day review. Its family tree reaches back 2 generations to 1996. 7 later devices descend from it. It has been recalled once.

Decided
Mar 22, 2018
Review
101 days
Class
Class II
Product code
EOQ
Recalls
1
Predicates
4

Its longest line of descent runs back 2 generations to K955065 (1996). 6 ancestors in all, the oldest K914181 (1991). 7 later devices descend from it, 2 citing it directly.

Other ancestors, by generationDescendants, by generation 1 generation back: 3 other ancestors2 generations back: 1 other ancestor 1 generation forward: 2 descendants2 generations forward: 3 descendants3 generations forward: 1 descendant4 generations forward: 1 descendant K962555 · Olympus FB Series Biopsy Forceps · Olympus America, Inc. · 1996K955065 · Olympus FB Series Biopsy Forceps · Olympus America, Inc. · 19960
  1. Root · 2 generations backK955065 Olympus FB Series Biopsy ForcepsOlympus America, Inc. · 1996
  2. 1 generation backK962555 Olympus FB Series Biopsy ForcepsOlympus America, Inc. · 1996
  3. This deviceK173760 Monarch Endoscopy Platform (Monarch Platform)Auris Surgical Robotics, Inc. · 2018
  4. Descendant · cites it directly · 5 of its ownK193534 Monarch PlatformAuris Health, Inc. · 2020 · Recalled
  5. Descendant · 2 generations on · 2 of its ownK211493 Monarch PlatformAuris Health, Inc. · 2021 · Recalled
  6. Descendant · 3 generations on · 1 of its ownK243219 MONARCH™ Platform (MON-000008)Auris Health, Inc. · 2025 · Recalled
  7. Descendant · 2 generations on · 1 of its ownK203614 Monarch BronchoscopeAuris Health, Inc., A Johnson and Johnson Family Company · 2021
  8. Descendant · 4 generations on · 0 of its ownK260382 MONARCH™ Platform (MON-000008)Auris Health, Inc. · 2026

Showing 5 of 7 descendants. See all descendants

Descendants cleared per year

2020: 12021: 22023: 22025: 12026: 1
2020high 2 (2021) · low 0 (2022)2026

Most influential descendants

Showing 5 of 7 · See all
  • K193534Monarch PlatformAuris Health, Inc. · 2020 · cites it directly5descendants
  • K211493Monarch PlatformAuris Health, Inc. · 2021 · 2 generations on2descendants
  • K243219MONARCH™ Platform (MON-000008)Auris Health, Inc. · 2025 · 3 generations on1descendant
  • K203614Monarch BronchoscopeAuris Health, Inc., A Johnson and Johnson Family Company · 2021 · 2 generations on1descendant
  • K260382MONARCH™ Platform (MON-000008)Auris Health, Inc. · 2026 · 4 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K955065Olympus FB Series Biopsy ForcepsOlympus America, Inc.1996—
−1K962555Olympus FB Series Biopsy ForcepsOlympus America, Inc.1996—
0 (this device)K173760Monarch Endoscopy Platform (Monarch Platform)Auris Surgical Robotics, Inc.2018—
+1K193534Monarch PlatformAuris Health, Inc.20204
+2K211493Monarch PlatformAuris Health, Inc.20212
+3K243219MONARCH™ Platform (MON-000008)Auris Health, Inc.20251
+2K203614Monarch BronchoscopeAuris Health, Inc., A Johnson and Johnson Family Company2021—
+4K260382MONARCH™ Platform (MON-000008)Auris Health, Inc.2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199110
199410
200710
201710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202010
202120
202320
202510
202610
FIG. 1 — Lineage of K173760, 1996–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in EOQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new EOQ device

  1. #1 K223299 Ambu® aScope™ 5 Broncho HD 5.0/2.2, Ambu®…score 18.4 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K071530Karl Storz Video Flexible Video Ent Endoscope System
Summary page 5
…: 21 CFR 874.4680 III. PREDICATE DEVICE(S) Trade name: Karl Storz Bronchoscope 510(k) Number: K071530 Classification Name: Bronchoscope (flexible or rigid) and accessories…
KARL STORZ Endoscopy-America, Inc.2007—
*K162611PeriFLEX
Summary page 5
…Karl Storz Endoscopy-America, Inc. Trade name: PeriFLEX Transbronchial Aspiration Needle 510(k) Number: K162611 Classification Name: Bronchoscope (flexible or rigid) and accessories…
Spiration, Inc.2017—
*K962555Olympus FB Series Biopsy Forceps
Summary page 5
…Manufacturer: Spiration, Inc. Trade name: Olympus FB series biopsy forceps 510(k) Number: K962555 Classification Name: Bronchoscope (flexible or rigid) and accessories…
Olympus America, Inc.1996—
*K944650Wang Bronchial Needle Brush
Summary page 6
…Page 2 of 8 Trade name: Wang Bronchial Needle Brush 510(k) Number: K944650 Classification Name: Bronchoscope (flexible or rigid) and accessories…
Mill-Rose Laboratory1994—
†K152319Auris Robotic Endoscopy System (ARES)Auris Surgical Robotics, Inc.2016—
†K151376superDimension Navigation SystemCovidien, LLC2015—
†K860582Tbi NeedleHobbs Medical, Inc.19862
†K925392Biopsy ForcepsEndo-Therapeutics, Inc.1993—
†K834402Gastrointestinal Sheath BrushHobbs Medical, Inc.19841

Also cleared against K071530: 4 other devices →

What descends from it? (7)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K193534Monarch PlatformAuris Health, Inc.20205
K223144Galaxy SystemNoah Medical Corp.20230

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Apr 19, 2019Class IIZ-0025-2020Labeling designReports of aspirating biopsy needle breakage

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 22 years and passes through 2 companies; a new generation was cleared every 21.6 years on median.
  • 1 of the 6 ancestors has a recall of any class.
  • Of its descendants, K193534 (Auris Health, Inc., 2020) has gone furthest, with 5 descendants of its own.
  • 4 other devices also cite its predicate K071530.

How does its category compare?

All EOQ devices

EOQ Bronchoscope (Flexible Or Rigid): FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · EOQ

20in 2025

2007: 22008: 22009: 32012: 22013: 42014: 32015: 62016: 32017: 42018: 72019: 112020: 102021: 152022: 112023: 122024: 132025: 202026 (partial year): 9
2007high 20 (2025) · low 0 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · EOQ

147in 2025

2009: 24 days median2013: 178 days median2014: 302 days median2015: 206 days median2016: 262 days median2017: 136 days median2018: 212 days median2019: 147 days median2020: 103 days median2021: 169 days median2022: 134 days median2023: 160 days median2024: 130 days median2025: 147 days median2026 (partial year): 206 days median
2007high 302 (2014) · low 24 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · EOQ

25in 2025

2011: 12012: 42016: 12019: 12020: 12021: 92022: 52023: 18, 4 Class I2024: 42025: 25, 24 Class I
2007high 25 (2025) · low 0 (2007)2026

Class I (28 since 2007) Class II/III not classified

Adverse event reports per year · EOQ

6,546in 2025

2007: 392008: 872009: 1142010: 1002011: 962012: 932013: 932014: 982015: 1322016: 2972017: 3372018: 2792019: 6542020: 5152021: 1,3582022: 2,5412023: 5,0642024: 6,0512025: 6,546
2007high 6,546 (2025) · low 39 (2007)2025

MAUDE reports naming product code EOQ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—039
20082—087
20093240114
20100—0100
20110—196
20122—493
20134178093
20143302098
201562060132
201632621297
201741360337
201872120279
2019111471654
2020101031515
20211516991,358
20221113452,541
20231216018 (4)5,064
20241313046,051
20252014725 (24)6,546
202692060—

What is it indicated for?

The Monarch Endoscopy Platform (Monarch Platform) and its accessories are intended to provide bronchoscopic visualization of and access to patient airways for diagnostic and therapeutic procedures.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K173760: Monarch Endoscopy Platform (Monarch Platform).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K173760

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026