K180038510(k) TraditionalCleared Jun 29, 2018175-day reviewClass II21 CFR 882.4560

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Nu Vasive, Incorporated · OLO Orthopedic Stereotaxic Instrument

Cleared on Jun 29, 2018 as substantially equivalent to K162313 (Nu Vasive, Incorporated, 2017) and 3 other predicates after a 175-day review. Its family tree reaches back 18 generations to 2004. 2 of the 225 devices in its family, counting itself, have a Class I recall. 3 later devices descend from it.

Decided
Jun 29, 2018
Review
175 days
Class
Class II
Product code
OLO
Recalls
None
Predicates
4

Its longest line of descent runs back 18 generations to K040583 (2004). 221 ancestors in all, the oldest K841189 (1984). 3 later devices descend from it, 1 citing it directly. 2 of the 225 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2017: 4 other ancestors2016: 3 other ancestors, 1 with a Class I recall12014: 5 other ancestors2009: 3 other ancestors2005: 16 other ancestors2015: 3 other ancestors, 1 with a Class I recall12013: 5 other ancestors2012: 4 other ancestors2011: 3 other ancestors2003: 10 other ancestors1999: 8 other ancestors2008: 5 other ancestors2006: 9 other ancestors2002: 13 other ancestors1998: 8 other ancestors1992: 6 other ancestors1989: 2 other ancestors1988: 4 other ancestors1984: 2 other ancestors2010: 2 other ancestors2004: 20 other ancestors2001: 11 other ancestors2000: 11 other ancestors1997: 7 other ancestors1994: 9 other ancestors1991: 1 other ancestor2007: 3 other ancestors1996: 5 other ancestors1995: 10 other ancestors1987: 2 other ancestors1986: 2 other ancestors1985: 2 other ancestors1993: 2 other ancestors1990: 3 other ancestors2021: 1 descendant cleared2025: 1 descendant cleared2023: 1 descendant cleared×7: 7 generations cleared close together, K040583 (2004), K041118 (2004), K042025 (2004), K043151 (2005), K050809 (2005), K052187 (2005), K053101 (2006) ×2: 2 generations cleared close together, K091442 (2009), K091974 (2009) K102555 · CD Horizon Spinal System · Medtronic Sofamor Danek USA, Inc. · 2010×2: 2 generations cleared close together, K112473 (2011), K113174 (2011) ×2: 2 generations cleared close together, K121680 (2012), K122862 (2012) K141605 · CD Horizon Spinal System · Medtronic Sofamor Danek USA, Inc. · 2014K143375 · CD HORIZON Spinal System, Medtronic Navigated Reusable Instruments · Medtronic Sofamor Danek USA, Inc. · 2015K153203 · Navigation Instruments · Globus Medical, Inc. · 2016K172623 · NuVasive Navigation Instruments · Nu Vasive, Incorporated · 201719801990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 3 other ancestors2 generations back: 8 other ancestors, 1 with a Class I recall13 generations back: 11 other ancestors, 1 with a Class I recall14 generations back: 17 other ancestors5 generations back: 31 other ancestors6 generations back: 48 other ancestors7 generations back: 29 other ancestors8 generations back: 19 other ancestors9 generations back: 13 other ancestors10 generations back: 21 other ancestors11 generations back: 3 other ancestors 1 generation forward: 1 descendant2 generations forward: 2 descendants K172623 · NuVasive Navigation Instruments · Nu Vasive, Incorporated · 2017K153203 · Navigation Instruments · Globus Medical, Inc. · 2016K143375 · CD HORIZON Spinal System, Medtronic Navigated Reusable Instruments · Medtronic Sofamor Danek USA, Inc. · 2015K141605 · CD Horizon Spinal System · Medtronic Sofamor Danek USA, Inc. · 2014K122862 · CD Horizon Spinal System · Medtronic Sofamor Danek USA, Inc. · 2012K121680 · CD Horizon Spinal System · Medtronic Sofamor Danek USA, Inc. · 2012K113174 · CD Horizon Spinal System · Medtronic Sofamor Danek USA, Inc. · 2011 · recalledK112473 · CD Horizon Spinal System · Medtronic Sofamor Danek, Inc. · 2011K102555 · CD Horizon Spinal System · Medtronic Sofamor Danek USA, Inc. · 2010K091974 · Modification to CD Horizon Spinal System · Medtronic Sofamor Danek USA, Inc. · 2009 · recalledK091442 · CD Horizon Spinal System · Medtronic Sofamor Danek · 2009K053101 · CD Horizon Spinal System · Medtronic Sofamor Danek · 2006K052187 · Modification to: CD Horizon Spinal System · Medtronic Sofamor Danek · 2005K050809 · CD Horizon Spinal System · Medtronic Sofamor Danek USA, Inc. · 2005K043151 · Modification to: CD Horizon Spinal System · Medtronic Sofamor Danek · 2005K042025 · Modification to CD Horizon Spinal System · Medtronic Sofamor Danek, Inc. · 2004 · recalledK041118 · Modification to CD Horizon Spinal System · Medtronic Sofamor Danek · 2004K040583 · Modification to: CD Horizon Spinal System · Medtronic Sofamor Danek · 2004−15−10−50
  1. Root · 18 generations backK040583 Modification to: CD Horizon Spinal SystemMedtronic Sofamor Danek · 2004
  2. 14 generations between
  3. 3 generations backK143375 CD HORIZON Spinal System, Medtronic Navigated Reusable InstrumentsMedtronic Sofamor Danek USA, Inc. · 2015
  4. 2 generations backK153203 Navigation InstrumentsGlobus Medical, Inc. · 2016
  5. 1 generation backK172623 NuVasive Navigation InstrumentsNu Vasive, Incorporated · 2017
  6. This deviceK180038 NuVasive Pulse SystemNu Vasive, Incorporated · 2018
  7. Descendant · cites it directly · 2 of its ownK210574 NuVasive Pulse SystemNu Vasive, Incorporated · 2021 · Recalled
  8. Descendant · 2 generations on · 0 of its ownK243814 NuVasive Pulse SystemGlobus Medical, Inc. · 2025
  9. Descendant · 2 generations on · 0 of its ownK230989 Rod Registration FrameNu Vasive, Incorporated · 2023
Show all 18 generations
  1. Root · 18 generations backK040583 Modification to: CD Horizon Spinal SystemMedtronic Sofamor Danek · 2004
  2. 17 generations backK041118 Modification to CD Horizon Spinal SystemMedtronic Sofamor Danek · 2004
  3. 16 generations backK042025 Modification to CD Horizon Spinal SystemMedtronic Sofamor Danek, Inc. · 2004 · Recalled
  4. 15 generations backK043151 Modification to: CD Horizon Spinal SystemMedtronic Sofamor Danek · 2005
  5. 14 generations backK050809 CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc. · 2005
  6. 13 generations backK052187 Modification to: CD Horizon Spinal SystemMedtronic Sofamor Danek · 2005
  7. 12 generations backK053101 CD Horizon Spinal SystemMedtronic Sofamor Danek · 2006
  8. 11 generations backK091442 CD Horizon Spinal SystemMedtronic Sofamor Danek · 2009
  9. 10 generations backK091974 Modification to CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc. · 2009 · Recalled
  10. 9 generations backK102555 CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc. · 2010
  11. 8 generations backK112473 CD Horizon Spinal SystemMedtronic Sofamor Danek, Inc. · 2011
  12. 7 generations backK113174 CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc. · 2011 · Recalled
  13. 6 generations backK121680 CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc. · 2012
  14. 5 generations backK122862 CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc. · 2012
  15. 4 generations backK141605 CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc. · 2014
  16. 3 generations backK143375 CD HORIZON Spinal System, Medtronic Navigated Reusable InstrumentsMedtronic Sofamor Danek USA, Inc. · 2015
  17. 2 generations backK153203 Navigation InstrumentsGlobus Medical, Inc. · 2016
  18. 1 generation backK172623 NuVasive Navigation InstrumentsNu Vasive, Incorporated · 2017
  19. This deviceK180038 NuVasive Pulse SystemNu Vasive, Incorporated · 2018

Class I recalls in this family

Most influential descendants

Showing 3 of 3 · See all
  • K210574NuVasive Pulse SystemNu Vasive, Incorporated · 2021 · cites it directly2descendants
  • K243814NuVasive Pulse SystemGlobus Medical, Inc. · 2025 · 2 generations on0descendants
  • K230989Rod Registration FrameNu Vasive, Incorporated · 2023 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−18K040583Modification to: CD Horizon Spinal SystemMedtronic Sofamor Danek2004—
−17K041118Modification to CD Horizon Spinal SystemMedtronic Sofamor Danek2004—
−16K042025Modification to CD Horizon Spinal SystemMedtronic Sofamor Danek, Inc.20044
−15K043151Modification to: CD Horizon Spinal SystemMedtronic Sofamor Danek2005—
−14K050809CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc.2005—
−13K052187Modification to: CD Horizon Spinal SystemMedtronic Sofamor Danek2005—
−12K053101CD Horizon Spinal SystemMedtronic Sofamor Danek2006—
−11K091442CD Horizon Spinal SystemMedtronic Sofamor Danek2009—
−10K091974Modification to CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc.20091
−9K102555CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc.2010—
−8K112473CD Horizon Spinal SystemMedtronic Sofamor Danek, Inc.2011—
−7K113174CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc.20111
−6K121680CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc.2012—
−5K122862CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc.2012—
−4K141605CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc.2014—
−3K143375CD HORIZON Spinal System, Medtronic Navigated Reusable InstrumentsMedtronic Sofamor Danek USA, Inc.2015—
−2K153203Navigation InstrumentsGlobus Medical, Inc.2016—
−1K172623NuVasive Navigation InstrumentsNu Vasive, Incorporated2017—
0 (this device)K180038NuVasive Pulse SystemNu Vasive, Incorporated2018—
+1K210574NuVasive Pulse SystemNu Vasive, Incorporated20211
+2K243814NuVasive Pulse SystemGlobus Medical, Inc.2025—
+2K230989Rod Registration FrameNu Vasive, Incorporated2023—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198420
198520
198620
198720
198840
198920
199030
199110
199260
199320
199490
1995100
199650
199770
199880
199980
2000110
2001110
2002130
2003100
2004200
2005160
200690
200730
200850
200930
201020
201130
201240
201350
201450
201531
201631
201740

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202110
202310
202510
FIG. 1 — Lineage of K180038, 2004–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OLO device

  1. #1 K240662 Spine Guidance Software (version 5.0); Xia 3/…score 23.7 · 15 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K162313NuVasive Next Generation NVM5 System
Summary page 5
…, LLZ, JAA C. Predicate Devices The subject NuVasive Pulse System is substantially equivalent to the primary predicate NuVasive Next Generation NVM5 System (K162313). It is also substantially equivalent to the additional predicate devices LessRay System (K173314), StealthStation S8 Spine…
Nu Vasive, Incorporated2017—
*K173314LessRay System
Summary page 5
…o the primary predicate NuVasive Next Generation NVM5 System (K162313). It is also substantially equivalent to the additional predicate devices LessRay System (K173314), StealthStation S8 Spine Software V1.0.0 (K170011), and NuVasive Navigation Instruments (K172623). D. Device Description…
Nu Vasive, Incorporated2017—
*K170011StealthStation S8 Spine Software v1.0.0
Summary page 5
…M5 System (K162313). It is also substantially equivalent to the additional predicate devices LessRay System (K173314), StealthStation S8 Spine Software V1.0.0 (K170011), and NuVasive Navigation Instruments (K172623). D. Device Description The Pulse System is a medical device consisting of…
Medtronic Navigation2017—
*K172623NuVasive Navigation Instruments
Summary page 5
…quivalent to the additional predicate devices LessRay System (K173314), StealthStation S8 Spine Software V1.0.0 (K170011), and NuVasive Navigation Instruments (K172623). D. Device Description The Pulse System is a medical device consisting of Pulse NVM5, Pulse LessRay, and Pulse Navi…
Nu Vasive, Incorporated2017—

Also cleared against K162313: 1 other device →

What descends from it? (3)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K210574NuVasive Pulse SystemNu Vasive, Incorporated20212

Has anything in its family been recalled? (2 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K153660StealthStation System with Cranial SoftwareMedtronic Navigation, Inc. · 2016 · 2 generations back · ◆ in the 2016 ancestors bar of FIG. 13 Class I recalls
  • K150216Synergy CranialMedtronic Navigation, Inc. · 2015 · 3 generations back · ◆ in the 2015 ancestors bar of FIG. 13 Class I recalls

What does this lineage say?

  • The line of descent spans 14 years and passes through 5 companies; a new generation was cleared every 6 months on median.
  • 30 of the 221 ancestors have a recall of any class; 2 have a Class I recall.
  • Of its descendants, K210574 (Nu Vasive, Incorporated, 2021) has gone furthest, with 2 descendants of its own.
  • 1 other device also cites its predicate K162313.

How does its category compare?

All OLO devices

OLO Orthopedic Stereotaxic Instrument: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · OLO

40in 2025

2009: 112010: 92011: 112012: 72013: 72014: 102015: 102016: 142017: 332018: 242019: 352020: 342021: 282022: 402023: 452024: 442025: 402026 (partial year): 42
2007high 45 (2023) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OLO

119in 2025

2009: 126 days median2010: 113 days median2011: 138 days median2012: 129 days median2013: 137 days median2014: 119 days median2015: 176 days median2016: 120 days median2017: 91 days median2018: 97 days median2019: 95 days median2020: 89 days median2021: 91 days median2022: 89 days median2023: 90 days median2024: 90 days median2025: 119 days median2026 (partial year): 109 days median
2007high 176 (2015) · low 89 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OLO

1in 2025

2010: 12011: 12012: 12014: 32015: 22016: 32017: 22018: 12019: 12020: 62022: 52023: 7, 1 Class I2024: 42025: 12026 (partial year): 6
2007high 7 (2023) · low 0 (2007)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · OLO

3,306in 2025

2008: 12009: 42010: 42011: 102012: 602013: 362014: 2452015: 4662016: 7502017: 1,0762018: 1,2302019: 1,5852020: 2,7462021: 1,6962022: 1,5682023: 1,4932024: 2,3532025: 3,306
2007high 3,306 (2025) · low 0 (2007)2025

MAUDE reports naming product code OLO, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—01
20091112604
2010911314
201111138110
20127129160
20137137036
2014101193245
2015101762466
2016141203750
2017339121,076
2018249711,230
2019359511,585
2020348962,746
2021289101,696
2022408951,568
202345907 (1)1,493
2024449042,353
20254011913,306
2026421096—

What is it indicated for?

The Pulse System is a medical device comprised of Pulse NVM5, Pulse LessRay, and Pulse Navigation. The Pulse NVM5 is intended for intraoperative neurophysiologic monitoring during spinal surgery, neck dissections, thoracic surgeries, and upper and lower extremities. The device provides information directly to the surgeon, to help assess a patient’s neurophysiologic status. The Pulse NVM5 provides this information by electrically stimulating nerves via…

Read the full statement (533 words)

The Pulse System is a medical device comprised of Pulse NVM5, Pulse LessRay, and Pulse Navigation.

The Pulse NVM5 is intended for intraoperative neurophysiologic monitoring during spinal surgery, neck dissections, thoracic surgeries, and upper and lower extremities. The device provides information directly to the surgeon, to help assess a patient’s neurophysiologic status. The Pulse NVM5 provides this information by electrically stimulating nerves via electrodes located on surgical accessories and monitoring electromyography (EMG), motor evoked potential (MEP) or somatosensory evoked potential (SSEP) responses of nerves. The System also integrates Bendini® software used to locate spinal implant instrumentation for the placement of spinal rods.

• XLIF (Detection) – The XLIF (Detection) function allows the surgeon to locate and evaluate spinal nerves, and is used as a nerve avoidance tool.

• Basic & Dynamic Screw Test – The Screw Test functions allow the surgeon to locate and evaluate spinal nerves by providing proximity information before, during or after bone preparation and placement of bone screws.

• Free Run EMG – The Free Run EMG function identifies spontaneous EMG activity of spinal nerves by continually displaying a live stream waveform of any mechanically induced myotome contractions.

• Twitch Test (Train of Four) – The Twitch Test Function allows the surgeon to assess moderate degrees of neuromuscular block in effect by evaluating muscle contraction following a train of four stimulation pulses.

• MEP – Transcranial or lumbar (i.e., conus in region of L1-L2) stimulation techniques for motor evoked potentials are used to assess for acute dysfunction in axonal conduction of the corticospinal tract and peripheral nerves. The MEP function provides an adjunctive method to allow the surgeon to monitor spinal cord and motor pathway integrity during procedures with a risk of surgically induced motor injury.

• SSEP – The SSEP function allows the surgeon to assess sensory spinal cord function in surgical procedures during which the spinal cord is at risk.

• Remote Access - The remote monitoring and local wireless control provides real-time capabilities to the Pulse System.

• Bendini – The Bendini Spinal Rod Bending function is used to locate spinal implant system instrumentation (screws, hooks) to determine their relative location to one another to generate bend instructions to shape a spinal rod. A surgeon is able to use those instructions and bend a rod using the Bendini Bender, a mechanical rod bender.

The Pulse LessRay is intended for use in any application where a fluoroscope is incorporated to aid in diagnosis and treatment of disease.

Pulse Navigation is intended as an intraoperative image-guided localization system in either open or minimally-invasive spinal surgical procedures. Instruments and implants tracked by a passive marker sensor system are virtually displayed on a patient's 2D or 3D radiographic image data. The system enables computer-assisted navigation for spinal surgical procedures in which the use of stereotactic surgery may be appropriate and where a reference to a rigid anatomical structure can be identified relative to the acquired image of the anatomy.

This may include the following spinal implant procedures:

o Pedicle Screw Placement (2D Navigation in Sacral and Lumbar Spine and 3D Navigation in Sacral and Thoracolumbar Spine)

o Interbody Device Placement (2D and 3D Navigation in Lumbar Spine via Lateral Approach)

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K180038: NuVasive Pulse System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K180038

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026