510(k) Report

510(k) · Cleared

Cleared

CLUNGENE Multi-Drug Test Dip Card, CLUNGENE Multi-Drug Test Easy Cup

K180255510(k) TraditionalCleared Feb 28, 201829-day reviewClass II21 CFR 862.3150

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Hangzhou Clongene Biotech Co., Ltd. · PTH Test, Barbiturate, Over The Counter

Cleared on Feb 28, 2018 as substantially equivalent to K142396 (Chemtron Biotech, Inc., 2014) after a 29-day review. Its family tree reaches back 6 generations to 1995.

Decided
Feb 28, 2018
Review
29 days
Class
Class II
Product code
PTH
Recalls
None
Predicates
1

Its longest line of descent runs back 6 generations to K945610 (1995). 27 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 6 generations backK945610 Abusign (TM) Amp, Doa-Amp, Accusign (TM) Amp-Doa-Amp, Biosign (TM)…Princeton BioMeditech Corp. · 1995
  2. 5 generations backK011673 Acon Amp One Step Amphetamine Test Strip, Acon Amp One Step…ACON Laboratories, Inc. · 2001
  3. 4 generations backK020313 Acon One Step Multi-Drug Multi-Line Screen Test Card; Acon One Step…Acon Laboratories Co. · 2002
  4. 3 generations backK031759 Acon Spectrum Multi-Drug Multi-Line Drug Screen Test Card and Acon…ACON Laboratories, Inc. · 2003 · Recalled
  5. 2 generations backK061718 Innovacon Spectrum II Test CardInnovacon, Inc. · 2006 · Recalled
  6. 1 generation backK142396 Chemtrue BUP/TCA Single/Multi-Panel Drug Screen Dip…Chemtron Biotech, Inc. · 2014
  7. This deviceK180255 CLUNGENE Multi-Drug Test Dip Card, CLUNGENE Multi-Drug Test Easy CupHangzhou Clongene Biotech Co., Ltd. · 2018
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K945610Abusign (TM) Amp, Doa-Amp, Accusign (TM) Amp-Doa-Amp, Biosign (TM) Amp, Doa-AmpPrinceton BioMeditech Corp.1995—
−5K011673Acon Amp One Step Amphetamine Test Strip, Acon Amp One Step Amphetamine Test…ACON Laboratories, Inc.2001—
−4K020313Acon One Step Multi-Drug Multi-Line Screen Test Card; Acon One Step Multi-Drug…Acon Laboratories Co.2002—
−3K031759Acon Spectrum Multi-Drug Multi-Line Drug Screen Test Card and Acon Spectrum…ACON Laboratories, Inc.20031
−2K061718Innovacon Spectrum II Test CardInnovacon, Inc.20066
−1K142396Chemtrue BUP/TCA Single/Multi-Panel Drug Screen Dip Card/Cup/Cassette TestsChemtron Biotech, Inc.2014—
0 (this device)K180255CLUNGENE Multi-Drug Test Dip Card, CLUNGENE Multi-Drug Test Easy CupHangzhou Clongene Biotech Co., Ltd.2018—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199620
199810
199910
200010
200170
200220
200320
200430
200510
200610
FIG. 1 — Lineage of K180255, 1995–2018Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PTH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K142396Chemtrue BUP/TCA Single/Multi-Panel Drug Screen Dip Card/Cup/Cassette Tests
Summary page 5
…II 21 CFR § 862.3620, Methadone Test Toxicology Methadone System (91) 5. Predicate Devices: K142396 The Chemtrue® Multi-Panel Drug Screen Dip Card Tests 6. Intended Use CLUNGENE® Multi-Drug Test Dip Card is competitive…
Chemtron Biotech, Inc.2014—

Also cleared against K142396: 7 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 23 years and passes through 6 companies; a new generation was cleared every 3.4 years on median.
  • 2 of the 27 ancestors have a recall of any class.
  • 7 other devices also cite its predicate K142396.

How does its category compare?

All PTH devices

PTH Test, Barbiturate, Over The Counter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · PTH

1in 2018

2018: 1
2007high 1 (2018) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PTH

Too few PTH 510(k)s in any year since 2007 to give a median.

Recalls per year · PTH

No recall names PTH since 2007.

Adverse event reports per year · PTH

No MAUDE report names PTH since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20181—00
20190—00
20200—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

CLUNGENE® Multi-Drug Test Dip Card is competitive binding, lateral flow immunochromatographic assay for qualitative and simultaneous detection of Amphetamine, Oxazepam, Cocaine, Marijuana, Methamphetamine, Morphine, Oxycodone, Secobarbital and Methadone in human urine at the cutoff concentrations of: Drug(Identifier) Calibrator Cut-off level Amphetamine d-Amphetamine 1000 ng/mL Oxazepam Oxazepam 300 ng/mL Cocaine Benzoylecgonine 300 ng/mL Marijuana…

Read the full statement (380 words)

CLUNGENE® Multi-Drug Test Dip Card is competitive binding, lateral flow immunochromatographic assay for qualitative and simultaneous detection of Amphetamine, Oxazepam, Cocaine, Marijuana, Methamphetamine, Morphine, Oxycodone, Secobarbital and Methadone in human urine at the cutoff concentrations of:

Drug(Identifier) Calibrator Cut-off level

Amphetamine d-Amphetamine 1000 ng/mL

Oxazepam Oxazepam 300 ng/mL

Cocaine Benzoylecgonine 300 ng/mL

Marijuana 11-Nor-△9-Tetrahydrocannabinol-9-COOH 50 ng/mL

Methamphetamine d-Methamphetamine 1000 ng/mL

Morphine Morphine 300 ng/mL

Oxycodone Oxycodone 100 ng/mL

Secobarbital Secobarbital 300 ng/mL

Methadone Methadone 300 ng/mL

Configuration of the CLUNGENE® Multi-Drug Test Dip Card can consist of any combination of the above listed drug analytes.

The test may yield positive results for the prescription drugs Oxazepam, Secobarbital and Oxycodone when taken at or above prescribed doses. It is not intended to distinguish between prescription use or abuse of these drugs. Clinical consideration and professional judgment should be exercised with any drug of abuse test result, particularly when the preliminary result is positive. The test provides only preliminary test results. A more specific alternative chemical method must be used in order to obtain a confirmed analytical result. GC/MS or LC/MS is the preferred confirmatory method.

For in vitro diagnostic use only.

CLUNGENE® Multi-Drug Test Easy Cup is competitive binding, lateral flow immunochromatographic assay for qualitative and simultaneous detection of Amphetamine, Oxazepam, Cocaine, Marijuana, Methamphetamine, Morphine, Oxycodone, Secobarbital and Methadone in human urine at the cutoff concentrations of:

Drug(Identifier) Calibrator Cut-off level

Amphetamine d-Amphetamine 1000 ng/mL

Oxazepam Oxazepam 300 ng/mL

Cocaine Benzoylecgonine 300 ng/mL

Marijuana 11-Nor-△9-Tetrahydrocannabinol-9-COOH 50 ng/mL

Methamphetamine d-Methamphetamine 1000 ng/mL

Morphine Morphine 300 ng/mL

Oxycodone Oxycodone 100 ng/mL

Secobarbital Secobarbital 300 ng/mL

Methadone Methadone 300 ng/mL

Configuration of the CLUNGENE® Multi-Drug Test Easy Cup can consist of any combination of the above listed drug analytes.

The test may yield positive results for the prescription drugs Oxazepam, Secobarbital and Oxycodone when taken at or above prescribed doses. It is not intended to distinguish between prescription use or abuse of these drugs. Clinical consideration and professional judgment should be exercised with any drug of abuse test result, particularly when the preliminary result is positive. The test provides only preliminary test results. A more specific alternative chemical method must be used in order to obtain a confirmed analytical result. GC/MS or LC/MS is the preferred confirmatory method.

For in vitro diagnostic use only.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K180255: CLUNGENE Multi-Drug Test Dip Card, CLUNGENE Multi-Drug Test Easy Cup.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K180255

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026