510(k) Report

510(k) · Cleared

Cleared

Steribite

K180949510(k) TraditionalCleared Nov 8, 2018211-day reviewClass II21 CFR 882.4840

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Rjr Surgical, Inc. · HAE Rongeur, Manual

Cleared on Nov 8, 2018 as substantially equivalent to K150428 (Integra Lifesciences Corp., 2015) after a 211-day review. Its family tree reaches back 3 generations to 1990.

Decided
Nov 8, 2018
Review
211 days
Class
Class II
Product code
HAE
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K902819 (1990). 4 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 3 generations backK902819 Laminectomy RogeurRuggles Corp. · 1990
  2. 2 generations backK092227 Jarit, Ruggles, R&B Redmond/ Redmond, Miltex, Meisterhand - Kerrison…Integra Lifesciences Corp. · 2010
  3. 1 generation backK150428 Integra (R) Jarit (R) Kerrison Rongeurs, Integra (R) Ruggles…Integra Lifesciences Corp. · 2015
  4. This deviceK180949 SteribiteRjr Surgical, Inc. · 2018
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K902819Laminectomy RogeurRuggles Corp.1990—
−2K092227Jarit, Ruggles, R&B Redmond/ Redmond, Miltex, Meisterhand - Kerrison RongeursIntegra Lifesciences Corp.2010—
−1K150428Integra (R) Jarit (R) Kerrison Rongeurs, Integra (R) Ruggles (TM)-Redmons (TM)…Integra Lifesciences Corp.2015—
0 (this device)K180949SteribiteRjr Surgical, Inc.2018—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410
FIG. 1 — Lineage of K180949, 1990–2018Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HAE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HAE device

  1. #1 K260446 Tontarra Punches and Rongeursscore 12.6 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K150428Integra (R) Jarit (R) Kerrison Rongeurs, Integra (R) Ruggles (TM)-Redmons (TM) Kerrison…
Summary page 4
…Class II Classification 21 CFR 882.4840 Manual Rongeur Product Code HAE Predicate Device K150428 Integra® Kerrison Rongeurs 21 CFR 882.4840 Manual Rongeur…
Integra Lifesciences Corp.2015—
†K140927Universal Navigation InstrumentsMedos International SARL2014—
†K150468Laminectomy Rongeurs, Kerrison Rongeurs, IVD RongeursK2 Medical GmbH & Co. KG2016—

Also cleared against K150428: 4 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 28 years and passes through 3 companies; a new generation was cleared every 5.2 years on median.
  • None of the 4 ancestors has a recall.
  • 4 other devices also cite its predicate K150428.

How does its category compare?

All HAE devices

HAE Rongeur, Manual: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · HAE

1in 2025

2007: 22008: 22010: 22012: 22013: 22015: 12016: 42018: 12020: 22021: 12022: 22023: 22025: 12026 (partial year): 1
2007high 4 (2016) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HAE

270in 2016

2016: 270 days median
2007high 270 (2016)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HAE

2in 2023

2023: 2
2007high 2 (2023) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HAE

10in 2025

2007: 42008: 52009: 62010: 102011: 312012: 472013: 202014: 152015: 252016: 342017: 252018: 292019: 242020: 252021: 122022: 132023: 102024: 92025: 10
2007high 47 (2012) · low 4 (2007)2025

MAUDE reports naming product code HAE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—04
20082—05
20090—06
20102—010
20110—031
20122—047
20132—020
20140—015
20151—025
20164270034
20170—025
20181—029
20190—024
20202—025
20211—012
20222—013
20232—210
20240—09
20251—010
20261—0—

What is it indicated for?

The Steribite® Rongeur is a manually operated instrument indicated for cutting or biting bone during surgery involving the skull or spinal column.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K180949: Steribite.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K180949

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026