510(k) Report

510(k) · Cleared

Cleared

Med-link Wrist Digital Blood Pressure Monitor, Med-link Upper Arm Digital Blood Pressure Monitor

K181154510(k) TraditionalCleared Aug 2, 2019458-day reviewClass II21 CFR 870.1130

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Shenzhen Med-Link Electronics Tech Co., Ltd. · DXN System, Measurement, Blood-Pressure, Non-Invasive

Cleared on Aug 2, 2019 as substantially equivalent to K130564 (Health & Life Co., Ltd., 2013) and 1 other predicate after a 458-day review. Its family tree reaches back 4 generations to 2000. 1 later device descends from it.

Decided
Aug 2, 2019
Review
458 days
Class
Class II
Product code
DXN
Recalls
None
Predicates
2

Its longest line of descent runs back 4 generations to K002115 (2000). 7 ancestors in all. 1 later device descends from it, 1 citing it directly.

  1. Root · 4 generations backK002115 A&D Medical Lifesource UB-401PC & UB-401 Digital Blood Pressure…A&D Engineering, Inc. · 2000
  2. 3 generations backK040229 A&D Medical Lifesource Digital Blood Pressure Monitors, Model UB-328A&D Engineering, Inc. · 2004
  3. 2 generations backK042967 A&D Medical Lifesource Digital Blood Pressure Monitors, Models…A&D Engineering, Inc. · 2004
  4. 1 generation backK130564 Full Automatic (Nibp) Blood Pressure MonitorHealth & Life Co., Ltd. · 2013
  5. This deviceK181154 Med-link Wrist Digital Blood Pressure Monitor, Med-link Upper Arm…Shenzhen Med-Link Electronics Tech Co., Ltd. · 2019
  6. Descendant · cites it directly · 0 of its ownK193386 Wrist Electronic SphygmomanometerShenzhen Changkun Technology Co., Ltd. · 2021

Most influential descendants

Showing 1 of 1 · See all
  • K193386Wrist Electronic SphygmomanometerShenzhen Changkun Technology Co., Ltd. · 2021 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K002115A&D Medical Lifesource UB-401PC & UB-401 Digital Blood Pressure MonitorsA&D Engineering, Inc.2000—
−3K040229A&D Medical Lifesource Digital Blood Pressure Monitors, Model UB-328A&D Engineering, Inc.2004—
−2K042967A&D Medical Lifesource Digital Blood Pressure Monitors, Models UB-511 & UB-512A&D Engineering, Inc.2004—
−1K130564Full Automatic (Nibp) Blood Pressure MonitorHealth & Life Co., Ltd.2013—
0 (this device)K181154Med-link Wrist Digital Blood Pressure Monitor, Med-link Upper Arm Digital…Shenzhen Med-Link Electronics Tech Co., Ltd.2019—
+1K193386Wrist Electronic SphygmomanometerShenzhen Changkun Technology Co., Ltd.2021—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200210
201010
201310

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202110
FIG. 1 — Lineage of K181154, 2000–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DXN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DXN device

  1. #1 K222125 Arm Blood Pressure Monitor, models AOJ-30A…score 18.5 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K130564Full Automatic (Nibp) Blood Pressure Monitor
Summary page 5
…on Full Blood Health & Life Class II, 21 CFR K130564 Automatic(NIBP) Pressure Co.,Ltd. DXN 870.113 1 Blood Pressure…
Health & Life Co., Ltd.2013—
*K123882Age Automatic Upper Arm Blood Pressure Monitor
Summary page 5
…0 Monitor, Model HL158LA AGE Automatic Noninvasi Ageless Health Class II, 21 CFR K123882 Upper Arm Blood ve blood Industrial Ltd. DXN 870.113 2 Pressure Monitor…
Ageless Health Industrial2013—

Also cleared against K130564: 1 other device →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K193386Wrist Electronic SphygmomanometerShenzhen Changkun Technology Co., Ltd.20210

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 19 years and passes through 3 companies; a new generation was cleared every 6.1 years on median.
  • None of the 7 ancestors has a recall.
  • Of its descendants, K193386 (Shenzhen Changkun Technology Co., Ltd., 2021) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K130564.

How does its category compare?

All DXN devices

DXN System, Measurement, Blood-Pressure, Non-Invasive: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.

FDA decisions per year · DXN

28in 2025

2007: 272008: 232009: 462010: 432011: 342012: 362013: 342014: 292015: 302016: 302017: 332018: 222019: 332020: 242021: 232022: 252023: 352024: 172025: 282026 (partial year): 29
2007high 46 (2009) · low 17 (2024)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DXN

142in 2025

2007: 118 days median2008: 82 days median2009: 73 days median2010: 94 days median2011: 72 days median2012: 116 days median2013: 150 days median2014: 133 days median2015: 97 days median2016: 144 days median2017: 184 days median2018: 235 days median2019: 156 days median2020: 198 days median2021: 190 days median2022: 137 days median2023: 182 days median2024: 107 days median2025: 142 days median2026 (partial year): 147 days median
2007high 235 (2018) · low 72 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DXN

3in 2024

2008: 12009: 32011: 12013: 12016: 12019: 12024: 3
2007high 3 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DXN

239in 2025

2007: 212008: 82009: 172010: 142011: 102012: 192013: 722014: 472015: 622016: 542017: 902018: 6172019: 962020: 1302021: 1622022: 1552023: 1622024: 2702025: 239
2007high 617 (2018) · low 8 (2008)2025

MAUDE reports naming product code DXN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200727118021
2008238218
20094673317
20104394014
20113472110
201236116019
201334150172
201429133047
20153097062
201630144154
201733184090
2018222350617
201933156196
2020241980130
2021231900162
2022251370155
2023351820162
2024171073270
2025281420239
2026291470—

What is it indicated for?

Med-link Wrist Digital Blood Pressure Monitor is non-invasive blood measurement of arterial blood pressure values in adults. It is intended to measure the diastolic, systolic blood pressures and pulse rate through an inflatable cuff wrapped around the wrist. It can be used by medical professionals or at home. The cuff circumference is limited to 13.5-19.5 cm. Med-link Upper Arm Digital Blood Pressure Monitor is non-invasive measurement of arterial blood…

Read the full statement (112 words)

Med-link Wrist Digital Blood Pressure Monitor is non-invasive blood measurement of arterial blood pressure values in adults. It is intended to measure the diastolic, systolic blood pressures and pulse rate through an inflatable cuff wrapped around the wrist. It can be used by medical professionals or at home. The cuff circumference is limited to 13.5-19.5 cm.

Med-link Upper Arm Digital Blood Pressure Monitor is non-invasive measurement of arterial blood pressure values in adults. It is intended to measure the diastolic, systolic blood pressures and pulse rate through an inflatable cuff wrapped around the upper arm. It can be used by medical professionals or at home. The cuff circumference is limited to 22-32cm.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K181154: Med-link Wrist Digital Blood Pressure Monitor, Med-link Upper Arm Digital Blood Pressure Monitor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K181154

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026