510(k) Report

510(k) · Cleared

Cleared

Cumulus Remover

K182002510(k) TraditionalCleared Oct 23, 201889-day reviewClass II21 CFR 884.6180

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Kitazato Corporation · MQL Media, Reproductive

Cleared on Oct 23, 2018 as substantially equivalent to K081639 (Medicult A/S, 2008) after an 89-day review. Its family tree reaches back 4 generations to 2000.

Decided
Oct 23, 2018
Review
89 days
Class
Class II
Product code
MQL
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K991334 (2000). 5 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 4 generations backK991334 Medi-Cult Hyaluronidase;Medicult A/S · 2000
  2. 3 generations backK031228 Synvitro HyadaseMedicult A/S · 2003
  3. 2 generations backK060699 Synvitro Cumulase (Hyaluronidase Medium)Medicult A/S · 2006
  4. 1 generation backK081639 Icsi CumulaseMedicult A/S · 2008
  5. This deviceK182002 Cumulus RemoverKitazato Corporation · 2018
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K991334Medi-Cult Hyaluronidase;Medicult A/S2000—
−3K031228Synvitro HyadaseMedicult A/S2003—
−2K060699Synvitro Cumulase (Hyaluronidase Medium)Medicult A/S2006—
−1K081639Icsi CumulaseMedicult A/S2008—
0 (this device)K182002Cumulus RemoverKitazato Corporation2018—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200510
FIG. 1 — Lineage of K182002, 2000–2018Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MQL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MQL device

  1. #1 K251305 Ultra-Fast Vitri; Ultra-Fast Warmscore 14.4 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K081639Icsi Cumulase
Summary page 4
…: 21 CFR 884.6180 Product code: MQL (Media, Reproductive) Regulatory class: II 5. Predicate Device ICSI Cumulase (K081639) manufactured by MediCult a/s. This predicate device is now branded by Origio a/s and has not been subject to any design relat…
Medicult A/S2008—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 18 years and passes through 2 companies; a new generation was cleared every 3.0 years on median.
  • None of the 5 ancestors has a recall.

How does its category compare?

All MQL devices

MQL Media, Reproductive: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · MQL

9in 2025

2007: 32008: 122009: 22010: 62011: 12012: 52014: 52015: 72016: 122017: 102018: 42019: 62020: 82021: 12022: 32023: 52024: 122025: 92026 (partial year): 3
2007high 12 (2008) · low 0 (2013)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MQL

225in 2025

2007: 212 days median2008: 151 days median2010: 235 days median2012: 253 days median2014: 142 days median2015: 87 days median2016: 170 days median2017: 113 days median2018: 94 days median2019: 170 days median2020: 257 days median2022: 316 days median2023: 199 days median2024: 195 days median2025: 225 days median2026 (partial year): 179 days median
2007high 316 (2022) · low 87 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MQL

1in 2023

2012: 12020: 12021: 22022: 12023: 1
2007high 2 (2021) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MQL

3in 2025

2012: 12013: 22014: 32016: 22023: 12024: 62025: 3
2007high 6 (2024) · low 0 (2007)2025

MAUDE reports naming product code MQL, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007321200
20081215100
20092—00
2010623500
20111—00
2012525311
20130—02
2014514203
201578700
20161217002
20171011300
201849400
2019617000
2020825710
20211—20
2022331610
2023519911
20241219506
2025922503
202631790—

What is it indicated for?

Cumulus Remover is for the removal of the cumulus complex and corona radiata surrounding the oocyte in preparation for ICSI.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K182002: Cumulus Remover.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K182002

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026