510(k) Report

510(k) · Cleared

Cleared

Simplexa GBS Direct, Simplexa GBS Positive Control Pack

K182467510(k) TraditionalCleared Nov 7, 201858-day reviewClass I21 CFR 866.3740

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Diasorin Molecular, LLC · NJR Nucleic Acid Amplification Assay System, Group B Streptococcus, Direct Specimen Test

Cleared on Nov 7, 2018 as substantially equivalent to K170557 (Genepoc, Inc., 2017) after a 58-day review. Its family tree reaches back 7 generations to 1994.

Decided
Nov 7, 2018
Review
58 days
Class
Class I
Product code
NJR
Recalls
None
Predicates
1

Its longest line of descent runs back 7 generations to K936112 (1994). No later device cites it as a predicate yet.

  1. Root · 7 generations backK936112 Strep B OiaBiostar, Inc. · 1994
  2. 6 generations backK991828 Strep B OiaBiostar, Inc. · 1999
  3. 5 generations backK022504 Idi-Strep B AssayInfectio Diagnostic, Inc. · 2002
  4. 4 generations backK062948 Smart GBS and Smartcycle DX System and Software, Version 1.7BCepheid · 2006
  5. 3 generations backK090191 Handylab GBS Assay, Handylab Jaguar Instrument, Handylab Dna…Handylab, Inc. · 2010
  6. 2 generations backK111860 BD Max GBS Assay, BD Max InstrumentBecton, Dickinson & CO · 2012 · Recalled
  7. 1 generation backK170557 GenePOC GBS LBGenepoc, Inc. · 2017
  8. This deviceK182467 Simplexa GBS Direct, Simplexa GBS Positive Control PackDiasorin Molecular, LLC · 2018
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K936112Strep B OiaBiostar, Inc.1994—
−6K991828Strep B OiaBiostar, Inc.1999—
−5K022504Idi-Strep B AssayInfectio Diagnostic, Inc.2002—
−4K062948Smart GBS and Smartcycle DX System and Software, Version 1.7BCepheid2006—
−3K090191Handylab GBS Assay, Handylab Jaguar Instrument, Handylab Dna Extraction Strip…Handylab, Inc.2010—
−2K111860BD Max GBS Assay, BD Max InstrumentBecton, Dickinson & CO20127
−1K170557GenePOC GBS LBGenepoc, Inc.2017—
0 (this device)K182467Simplexa GBS Direct, Simplexa GBS Positive Control PackDiasorin Molecular, LLC2018—
FIG. 1 — Lineage of K182467, 1994–2018Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NJR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new NJR device

  1. #1 K222638 Xpert® Xpress GBS, GeneXpert® Dx System…score 7.0 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K170557GenePOC GBS LB
Summary page 4
…eptococcus, Direct Specimen Testing Classification Class I Predicate Devices GenePOC GBS LB Assay K170557 Intended Use Simplexa™ GBS Direct The DiaSorin Molecular Simplexa™ GBS Direct assay is a real-time polymerase chain reaction (PC…
Genepoc, Inc.2017—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 24 years and passes through 7 companies; a new generation was cleared every 3.5 years on median.
  • 1 of the 7 ancestors has a recall of any class.

How does its category compare?

All NJR devices

NJR Nucleic Acid Amplification Assay System, Group B Streptococcus, Direct Specimen Test: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · NJR

1in 2023

2010: 12011: 12012: 32013: 12015: 12016: 12017: 22018: 32022: 12023: 1
2007high 3 (2012) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NJR

87in 2018

2012: 162 days median2018: 87 days median
2007high 162 (2012) · low 87 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · NJR

1in 2025

2007: 12011: 12012: 22015: 12022: 12024: 22025: 1
2007high 2 (2012) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · NJR

14in 2024

2014: 12017: 12020: 12021: 22022: 32023: 82024: 14
2007high 14 (2024) · low 0 (2007)2025

MAUDE reports naming product code NJR, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—10
20080—00
20090—00
20101—00
20111—10
2012316220
20131—00
20140—01
20151—10
20161—00
20172—01
201838700
20190—00
20200—01
20210—02
20221—13
20231—08
20240—214
20250—10
20260—0—

What is it indicated for?

Simplexa™ GBS Direct The DiaSorin Molecular Simplexa™ GBS Direct assay is a real-time polymerase chain reaction (PCR) assay intended for use on the LIAISON® MDX instrument for the in vitro qualitative detection of Group B Streptococcus (GBS) nucleic acid from 18 to 24 hour Lim broth enrichments of vaginal/rectal specimen swabs obtained from antepartum women. Assay results can be used as an aid in determining the colonization status of antepartum women…

Read the full statement (144 words)

Simplexa™ GBS Direct

The DiaSorin Molecular Simplexa™ GBS Direct assay is a real-time polymerase chain reaction (PCR) assay intended for use on the LIAISON® MDX instrument for the in vitro qualitative detection of Group B Streptococcus (GBS) nucleic acid from 18 to 24 hour Lim broth enrichments of vaginal/rectal specimen swabs obtained from antepartum women. Assay results can be used as an aid in determining the colonization status of antepartum women, but are not intended to diagnose or monitor treatment of a GBS infection.

The Simplexa™ GBS Direct assay does not provide susceptibility results. Culture isolates are needed to perform susceptibility testing as recommended for penicillin-allergic women.

Simplexa™ GBS Positive Control Pack

The Simplexa™ GBS Positive Control Pack is intended to be used as a control with the Simplexa™ GBS Direct kit. This control is not intended for use with other assays or systems.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K182467: Simplexa GBS Direct, Simplexa GBS Positive Control Pack.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K182467

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026