510(k) · Cleared
ClearedMasimo Rad-67 Pulse CO-Oximeter and Accessories
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Masimo Corporation · DQA Oximeter
Cleared on Mar 22, 2019 as substantially equivalent to K091057 (Masimo Corporation, 2009) and 1 other predicate after a 158-day review. Its family tree reaches back 9 generations to 2000.
- Decided
- Mar 22, 2019
- Review
- 158 days
- Class
- Class II
- Product code
- DQA
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 9 generations to K000126 (2000). 11 ancestors in all, the oldest K853990 (1985). No later device cites it as a predicate yet.
- Root · 9 generations backK000126 Masimo Set Radical Pulse Oximeter with Satshare, Masimo…Masimo Corp. · 2000
- 5 generations between
- 3 generations backK080238 Masimo Rainbow Set Radical 7 Pulse CO-Oximeter, Masimo Rainbow Set…Masimo Corporation · 2008 · Recalled
- 2 generations backK082052 Masimo Rainbow Set Radcheck Pulse CO-Oximeter, Radcheck, Rad 57 Spot…Masimo Corporation · 2008
- 1 generation backK091057 Masimo Rainbow Set Pronto Pulse CO-Oximeter and AccessoriesMasimo Corporation · 2009
- This deviceK182887 Masimo Rad-67 Pulse CO-Oximeter and AccessoriesMasimo Corporation · 2019
Show all 9 generations
- Root · 9 generations backK000126 Masimo Set Radical Pulse Oximeter with Satshare, Masimo…Masimo Corp. · 2000
- 8 generations backK031330 Modification to Masimo Set Radical Pulse Oximeter with Satshare and…Masimo Corp. · 2003
- 7 generations backK033296 Masimo Set Rad-5 Pulse Oximeter, Model Rad-5; Masimo Set Rad-5V…Masimo Corp. · 2004 · Recalled
- 6 generations backK042536 Masimo Set Rad 57 Pulse CO-OximeterMasimo Corporation · 2005 · Recalled
- 5 generations backK053477 Masimo Set Rad 57 CM and M Pulse CO-OximetersMasimo Corporation · 2006
- 4 generations backK061204 Masimo Set Radical 7 Pulse CO-OximeterMasimo Corporation · 2006
- 3 generations backK080238 Masimo Rainbow Set Radical 7 Pulse CO-Oximeter, Masimo Rainbow Set…Masimo Corporation · 2008 · Recalled
- 2 generations backK082052 Masimo Rainbow Set Radcheck Pulse CO-Oximeter, Radcheck, Rad 57 Spot…Masimo Corporation · 2008
- 1 generation backK091057 Masimo Rainbow Set Pronto Pulse CO-Oximeter and AccessoriesMasimo Corporation · 2009
- This deviceK182887 Masimo Rad-67 Pulse CO-Oximeter and AccessoriesMasimo Corporation · 2019
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −9 | K000126 | Masimo Set Radical Pulse Oximeter with Satshare, Masimo… | Masimo Corp. | 2000 | — |
| −8 | K031330 | Modification to Masimo Set Radical Pulse Oximeter with Satshare and Lnop… | Masimo Corp. | 2003 | — |
| −7 | K033296 | Masimo Set Rad-5 Pulse Oximeter, Model Rad-5; Masimo Set Rad-5V Pulse… | Masimo Corp. | 2004 | 1 |
| −6 | K042536 | Masimo Set Rad 57 Pulse CO-Oximeter | Masimo Corporation | 2005 | 1 |
| −5 | K053477 | Masimo Set Rad 57 CM and M Pulse CO-Oximeters | Masimo Corporation | 2006 | — |
| −4 | K061204 | Masimo Set Radical 7 Pulse CO-Oximeter | Masimo Corporation | 2006 | — |
| −3 | K080238 | Masimo Rainbow Set Radical 7 Pulse CO-Oximeter, Masimo Rainbow Set Rad 87… | Masimo Corporation | 2008 | 1 |
| −2 | K082052 | Masimo Rainbow Set Radcheck Pulse CO-Oximeter, Radcheck, Rad 57 Spot Check | Masimo Corporation | 2008 | — |
| −1 | K091057 | Masimo Rainbow Set Pronto Pulse CO-Oximeter and Accessories | Masimo Corporation | 2009 | — |
| 0 (this device) | K182887 | Masimo Rad-67 Pulse CO-Oximeter and Accessories | Masimo Corporation | 2019 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1985 | 1 | 0 |
| 2004 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DQA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DQA device
- #1 K221282 Empatica Health Monitoring Platformscore 20.1 · 38 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K091057 | Masimo Rainbow Set Pronto Pulse CO-Oximeter and AccessoriesSummary page 5…mber: Reason for Premarket New Device – Masimo Rad-67™ Pulse CO-Oximeter and Notification: Accessories Predicate Device: K091057- Masimo Rainbow SET Pronto Pulse CO-Oximeter Performance Standards No performance standards for the above device have… | 2009 |
| * | K080238 | Masimo Rainbow Set Radical 7 Pulse CO-Oximeter, Masimo Rainbow Set Rad 87 Pulse…Summary page 6…ni sensor is indicated for adult populations for SpHb®. The rainbow DCI-mini sensor measurement technology is the same as the predicate (rainbow DCI sensor cleared under K080238), except that the rainbow DCI-mini sensor has been designed to be smaller to accommodate a smaller application sites such as the… | 2008 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 19 years and passes through 2 companies; a new generation was cleared every 11 months on median.
- 3 of the 11 ancestors have a recall of any class.
- 2 other devices also cite its predicate K091057.
How does its category compare?
All DQA devicesDQA Oximeter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.
FDA decisions per year · DQA
15in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DQA
182in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DQA
3in 2024
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DQA
399in 2025
MAUDE reports naming product code DQA, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 20 | 122 | 6 | 325 |
| 2008 | 22 | 97 | 5 | 312 |
| 2009 | 35 | 117 | 29 | 281 |
| 2010 | 29 | 127 | 4 | 185 |
| 2011 | 15 | 195 | 1 | 164 |
| 2012 | 14 | 120 | 0 | 322 |
| 2013 | 15 | 182 | 0 | 468 |
| 2014 | 11 | 175 | 2 | 1,124 |
| 2015 | 13 | 158 | 1 | 2,082 |
| 2016 | 14 | 246 | 0 | 1,775 |
| 2017 | 9 | 200 | 0 | 1,190 |
| 2018 | 18 | 260 | 32 | 694 |
| 2019 | 19 | 158 | 0 | 548 |
| 2020 | 15 | 126 | 0 | 426 |
| 2021 | 10 | 174 | 0 | 553 |
| 2022 | 20 | 265 | 0 | 478 |
| 2023 | 13 | 317 | 0 | 392 |
| 2024 | 14 | 285 | 3 | 545 |
| 2025 | 15 | 182 | 0 | 399 |
| 2026 | 8 | 187 | 0 | — |
What is it indicated for?
The Masimo Rad-67™ Pulse CO-Oximeter and Accessories are intended for use in clinical and non-clinical settings. The Masimo Rad-67™ Pulse CO-Oximeter and Accessories are indicated for non-invasive spot-check monitoring of functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate (PR) for adult and pediatric patients who are well or poorly perfused during both motion and no motion conditions. The Masimo Rad-67™ Pulse CO-Oximeter and…
Read the full statement (154 words)
The Masimo Rad-67™ Pulse CO-Oximeter and Accessories are intended for use in clinical and non-clinical settings.
The Masimo Rad-67™ Pulse CO-Oximeter and Accessories are indicated for non-invasive spot-check monitoring of functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate (PR) for adult and pediatric patients who are well or poorly perfused during both motion and no motion conditions.
The Masimo Rad-67™ Pulse CO-Oximeter and Accessories are indicated for non-invasive spot-check monitoring of total hemoglobin concentration (SpHb®) for adult patients.
The rainbow DCI-mini sensor is intended for use in clinical and non-clinical settings.
The rainbow DCI-mini sensor is indicated for non-invasive spot-check monitoring and continuous monitoring of functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate (PR) for adult and pediatric patients who are well or poorly perfused during both motion and no motion conditions.
The rainbow DCI-mini sensor is indicated for non-invasive spot-check monitoring of total hemoglobin concentration (SpHb®) for adult patients.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K182887 · printed Nov 4, 2026
Cite this page
510(k) Report. “K182887: Masimo Rad-67 Pulse CO-Oximeter and Accessories.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K182887