510(k) Report

510(k) · Cleared

Recalled · Class II · 2024

Dilator Sets

K183036510(k) TraditionalCleared Dec 20, 201849-day reviewClass II21 CFR 870.1310Recalls 3

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Cook Incorporated · DRE Dilator, Vessel, For Percutaneous Catheterization

Cleared on Dec 20, 2018 as substantially equivalent to K162389 (Medcomp ( Medical Components), 2017) and 1 other predicate after a 49-day review. Its family tree reaches back 2 generations to 1996. 1 later device descends from it. It has been recalled 3 times.

Decided
Dec 20, 2018
Review
49 days
Class
Class II
Product code
DRE
Recalls
3
Predicates
2

Its longest line of descent runs back 2 generations to K961904 (1996). 4 ancestors in all, the oldest K801113 (1980). 1 later device descends from it, 1 citing it directly.

Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 1 other ancestor 1 generation forward: 1 descendant K990808 · PBN Dilators · Medical Device Technologies, Inc. · 1999K961904 · AQ Hydrophilic Dilators · Cook Urological, Inc. · 19960
  1. Root · 2 generations backK961904 AQ Hydrophilic DilatorsCook Urological, Inc. · 1996
  2. 1 generation backK990808 PBN DilatorsMedical Device Technologies, Inc. · 1999
  3. This deviceK183036 Dilator SetsCook Incorporated · 2018
  4. Descendant · cites it directly · 0 of its ownK210734 Endovascular Dilator and SetsCook Incorporated · 2021

Most influential descendants

Showing 1 of 1 · See all
  • K210734Endovascular Dilator and SetsCook Incorporated · 2021 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K961904AQ Hydrophilic DilatorsCook Urological, Inc.1996—
−1K990808PBN DilatorsMedical Device Technologies, Inc.1999—
0 (this device)K183036Dilator SetsCook Incorporated2018—
+1K210734Endovascular Dilator and SetsCook Incorporated2021—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198010
201710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202110
FIG. 1 — Lineage of K183036, 1996–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DRE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DRE device

  1. #1 K261310 FlexTract Deflectable-Rotational Dilator…score 12.0 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K162389Medcomp Vessel Dilator
Summary page 4
…logy Regulation: 21 CFR §870.1310, 21 CFR §876.5010 Product Code: DRE, FGE Predicate Devices: ▪ Medcomp® Vessel Dilator (Medcomp®, K162389) ▪ PBN Dilators (Medical Device Technologies, Inc., K990808) Reference Devices: ▪ Peel-Away Introducer Set (Cook Inc., K170020)…
Medcomp ( Medical Components)2017—
*K990808PBN Dilators
Summary page 4
…876.5010 Product Code: DRE, FGE Predicate Devices: ▪ Medcomp® Vessel Dilator (Medcomp®, K162389) ▪ PBN Dilators (Medical Device Technologies, Inc., K990808) Reference Devices: ▪ Peel-Away Introducer Set (Cook Inc., K170020) ▪ Royal Flush Catheter (Cook Inc., K171264) ▪ CrossCath Suppo…
Medical Device Technologies, Inc.1999—
†K170020Peel-Away Introducer SetCook Incorporated2017—
†K171264Royal Flush CatheterCook Incorporated2018—
†K161801CrossCath Support CatheterCook Incorporated2016Class I

Also cleared against K162389: 1 other device →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K210734Endovascular Dilator and SetsCook Incorporated20210

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Mar 1, 2024Class IIZ-1532-2024Under Investigation by firmPackaging may have low seal strength and not meet peel strength specifications, compromising device sterility
Mar 1, 2024Class IIZ-1530-2024Under Investigation by firmPackaging may have low seal strength and not meet peel strength specifications, compromising device sterility
Mar 1, 2024Class IIZ-1531-2024Under Investigation by firmPackaging may have low seal strength and not meet peel strength specifications, compromising device sterility

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 22 years and passes through 3 companies; a new generation was cleared every 19.1 years on median.
  • None of the 4 ancestors has a recall.
  • Of its descendants, K210734 (Cook Incorporated, 2021) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K162389.

How does its category compare?

All DRE devices

DRE Dilator, Vessel, For Percutaneous Catheterization: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · DRE

3in 2025

2007: 52008: 22009: 22010: 12011: 12012: 12013: 42014: 62015: 42016: 32017: 42018: 22019: 32020: 32021: 12022: 32023: 22024: 12025: 32026 (partial year): 1
2007high 6 (2014) · low 1 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DRE

31in 2025

2007: 160 days median2013: 111 days median2014: 72 days median2015: 30 days median2016: 90 days median2017: 108 days median2019: 68 days median2020: 30 days median2022: 261 days median2025: 31 days median
2007high 261 (2022) · low 30 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DRE

1in 2016

2009: 22010: 22011: 12015: 12016: 12026 (partial year): 1, 1 Class I
2007high 2 (2009) · low 0 (2007)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · DRE

356in 2025

2007: 812008: 382009: 692010: 732011: 902012: 1322013: 1202014: 822015: 822016: 842017: 1012018: 1262019: 1442020: 1202021: 1152022: 1362023: 3862024: 3252025: 356
2007high 386 (2023) · low 38 (2008)2025

MAUDE reports naming product code DRE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20075160081
20082—038
20092—269
20101—273
20111—190
20121—0132
201341110120
2014672082
2015430182
2016390184
201741080101
20182—0126
20193680144
20203300120
20211—0115
202232610136
20232—0386
20241—0325
20253310356
20261—1 (1)—

What is it indicated for?

Intended to be used for dilating puncture sites or catheter tracts for percutaneous placement of devices for vascular and non-vascular applications such as in the venous, arterial, biliary and renal systems.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K183036: Dilator Sets.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K183036

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026