510(k) Report

510(k) · Cleared

Recalled · Class II · 2022

Coag-Sense Prothrombin Time (PT) / INR Monitoring Device

K183255510(k) TraditionalCleared Feb 21, 201992-day reviewClass II21 CFR 864.7750Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Coagusense, Inc. · GJS Test, Time, Prothrombin

Cleared on Feb 21, 2019 as substantially equivalent to K050243 (Farallon Medial, Inc., 2005) and 1 other predicate after a 92-day review. Its family tree reaches back 3 generations to 1997. 3 of the 9 devices in its family, counting itself, have a Class I recall. 1 later device descends from it. It has been recalled once.

Decided
Feb 21, 2019
Review
92 days
Class
Class II
Product code
GJS
Recalls
1
Predicates
2

Its longest line of descent runs back 3 generations to K962571 (1997). 7 ancestors in all. 1 later device descends from it, 1 citing it directly. 3 of the 9 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2005: 1 other ancestor2007: 1 other ancestor, 1 with a Class I recall12002: 2 other ancestors, 2 with a Class I recall22022: 1 descendant clearedK962571 · Coaguchek PST System · Boehringer Mannheim Corp. · 1997 · recalledK030845 · Coaguchek PT.S Test for Prothrombin Time Self-Testing · Roche Diagnostics Corp. · 2003 · recalledK093243 · Coagusense Self-Test Prothrombin Time/Inr Monitoring System · Coagusense, Inc. · 2010 · recalled1995200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 2 other ancestors, 2 with a Class I recall23 generations back: 1 other ancestor, 1 with a Class I recall1 1 generation forward: 1 descendant K093243 · Coagusense Self-Test Prothrombin Time/Inr Monitoring System · Coagusense, Inc. · 2010 · recalledK030845 · Coaguchek PT.S Test for Prothrombin Time Self-Testing · Roche Diagnostics Corp. · 2003 · recalledK962571 · Coaguchek PST System · Boehringer Mannheim Corp. · 1997 · recalled0
  1. Root · 3 generations backK962571 Coaguchek PST SystemBoehringer Mannheim Corp. · 1997 · Recalled
  2. 2 generations backK030845 Coaguchek PT.S Test for Prothrombin Time Self-TestingRoche Diagnostics Corp. · 2003 · Recalled
  3. 1 generation backK093243 Coagusense Self-Test Prothrombin Time/Inr Monitoring SystemCoagusense, Inc. · 2010 · Recalled
  4. This deviceK183255 Coag-Sense Prothrombin Time (PT) / INR Monitoring DeviceCoagusense, Inc. · 2019
  5. Descendant · cites it directly · 0 of its ownK212779 Coag-Sense Prothrombin (PT) / INR Monitoring System for Patient…Coagusense, Inc. · 2022

Class I recalls in this family

Most influential descendants

Showing 1 of 1 · See all
  • K212779Coag-Sense Prothrombin (PT) / INR Monitoring System for Patient Self-TestingCoagusense, Inc. · 2022 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K962571Coaguchek PST SystemBoehringer Mannheim Corp.19974
−2K030845Coaguchek PT.S Test for Prothrombin Time Self-TestingRoche Diagnostics Corp.20031
−1K093243Coagusense Self-Test Prothrombin Time/Inr Monitoring SystemCoagusense, Inc.20101
0 (this device)K183255Coag-Sense Prothrombin Time (PT) / INR Monitoring DeviceCoagusense, Inc.2019—
+1K212779Coag-Sense Prothrombin (PT) / INR Monitoring System for Patient Self-TestingCoagusense, Inc.2022—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200222
200510
200711

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202210
FIG. 1 — Lineage of K183255, 1997–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

3 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GJS device

  1. #1 K243543 microINR Systemscore 13.4 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K050243Immedia Prothrombin Time System
Summary page 4
…Number Coag-Sense Prothrombin Time (PT)/INR System Farallon Medical (CoaguSense Inc.) K050243 (Professional Use) Coag-Sense Prothrombin Time (PT)/INR System CoaguSense Inc. K09324…
Farallon Medial, Inc.2005—
*K093243Coagusense Self-Test Prothrombin Time/Inr Monitoring System
Summary page 4
…allon Medical (CoaguSense Inc.) K050243 (Professional Use) Coag-Sense Prothrombin Time (PT)/INR System CoaguSense Inc. K093243 (Patient Self-Testing) CoaguSense, Inc. Appendix S - 1 === Pag…
Coagusense, Inc.20101

Also cleared against K050243: 1 other device →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K212779Coag-Sense Prothrombin (PT) / INR Monitoring System for Patient Self-TestingCoagusense, Inc.20220

Has anything in its family been recalled? (3 Class I)

Recalls of this device

DateClassRecallRoot causeReason
May 25, 2022Class IIZ-1583-2022Environmental controlFacility Temperature excursions (from June 2021-August 2021) prior to delivery; exposure to higher temperatures may have impacted product effectiveness. All lots received between 06/01/21-9/30/21.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K072727Inratio 2 PT Monitoring SystemHemosense, Inc. · 2007 · 2 generations back · ◆ in the 2007 ancestors bar of FIG. 14 Class I recalls
  • K021923Inratio Self-TestHemosense, Inc. · 2002 · 2 generations back · ◆ in the 2002 ancestors bar of FIG. 12 Class I recalls
  • K020679InratioHemosense, Inc. · 2002 · 3 generations back · ◆ in the 2002 ancestors bar of FIG. 14 Class I recalls

What does this lineage say?

  • The line of descent spans 22 years and passes through 3 companies; a new generation was cleared every 6.9 years on median.
  • 6 of the 7 ancestors have a recall of any class; 3 have a Class I recall.
  • Of its descendants, K212779 (Coagusense, Inc., 2022) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K050243.

How does its category compare?

All GJS devices

GJS Test, Time, Prothrombin: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.

FDA decisions per year · GJS

3in 2025

2007: 42008: 12010: 42012: 12013: 12014: 12016: 12017: 12018: 22019: 22020: 12022: 32023: 22024: 12025: 3
2007high 4 (2007) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GJS

60in 2025

2007: 77 days median2010: 168 days median2022: 399 days median2025: 60 days median
2007high 399 (2022) · low 60 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GJS

1in 2022

2007: 52008: 32009: 42010: 22011: 12012: 12013: 12014: 4, 3 Class I2017: 52018: 3, 2 Class I2020: 22021: 12022: 1
2007high 5 (2007) · low 0 (2015)2026

Class I (5 since 2007) Class II/III not classified

Adverse event reports per year · GJS

105in 2025

2007: 4392008: 4202009: 8762010: 2,1772011: 2,9652012: 2,1982013: 2,5842014: 2,3972015: 1,2602016: 8642017: 5322018: 1,9582019: 2,3852020: 1,3902021: 1,3592022: 1,2102023: 8092024: 1772025: 105
2007high 2,965 (2011) · low 105 (2025)2025

MAUDE reports naming product code GJS, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20074775439
20081—3420
20090—4876
2010416822,177
20110—12,965
20121—12,198
20131—12,584
20141—4 (3)2,397
20150—01,260
20161—0864
20171—5532
20182—3 (2)1,958
20192—02,385
20201—21,390
20210—11,359
2022339911,210
20232—0809
20241—0177
20253600105
20260—0—

What is it indicated for?

The Coag-Sense® Prothrombin Time (PT) / INR Monitoring System (Self-Test) is an in vitro diagnostic device that provides quantitative prothrombin time (PT) results, expressed in seconds and INR units. It uses fresh capillary whole blood.

It is intended for use by properly selected and suitably trained patients or their caregivers on the order of the treating physician to monitor patients who are on anticoagulation therapy. Patients should be stabilized on warfarin-type (coumarin) anticoagulation therapy prior to self-testing.

The device is not intended to be used for screening purposes.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K183255: Coag-Sense Prothrombin Time (PT) / INR Monitoring Device.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K183255

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026