510(k) · Cleared
ClearedFull Automatic (NIBP) Blood Pressure Monitor
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Health & Life Co., Ltd. · DXN System, Measurement, Blood-Pressure, Non-Invasive
Cleared on Sep 16, 2019 as substantially equivalent to K160145 (Health & Life Co., Ltd., 2016) after a 199-day review. Its family tree reaches back 10 generations to 1985. 2 later devices descend from it.
- Decided
- Sep 16, 2019
- Review
- 199 days
- Class
- Class II
- Product code
- DXN
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 10 generations to K850316 (1985). 22 ancestors in all. 2 later devices descend from it, 2 citing it directly.
- Root · 10 generations backK850316 Unisonic Electronic Digital BP Monitor Ebm-2050Nihon Seimitsu Sokki Co., Ltd. · 1985
- 6 generations between
- 3 generations backK131121 Full Automatic (Nibp) Blood Pressure MonitorHealth & Life Co., Ltd. · 2013
- 2 generations backK142968 Full Automatic (NIBP) Blood Pressure MonitorHealth & Life Co., Ltd. · 2014
- 1 generation backK160145 Full Automatic (NIBP) Blood Pressure MonitorHealth & Life Co., Ltd. · 2016
- This deviceK190507 Full Automatic (NIBP) Blood Pressure MonitorHealth & Life Co., Ltd. · 2019
- Descendant · cites it directly · 0 of its ownK200437 Blood Pressure MonitorShenzhen Jamr Technology Co., Ltd. · 2020
- Descendant · cites it directly · 0 of its ownK200521 Full Automatic (NIBP) Blood Pressure MonitorHealth & Life Co., Ltd. · 2020
Show all 10 generations
- Root · 10 generations backK850316 Unisonic Electronic Digital BP Monitor Ebm-2050Nihon Seimitsu Sokki Co., Ltd. · 1985
- 9 generations backK993890 Digital Blood Pressure Monitor, Model DS-181Nihon Seimitsu Sokki Co., Ltd. · 1999
- 8 generations backK050697 Model DS-1901 Digital Blood Pressure MonitorNihon Seimitsu Sokki Co., Ltd. · 2005
- 7 generations backK071384 Modification to: Digital Blood Pressure Monitor, Model 1901Nihon Seimitsu Sokki Co., Ltd. · 2007
- 6 generations backK080177 Wrist Blood Pressure Monitor, Model WS-1100/WS-1100PVNihon Seimitsu Sokki Co., Ltd. · 2008
- 5 generations backK092161 Full Automatic (Nibp) Blood Pressure Monitor, Model HL868BFHealth & Life Co., Ltd. · 2009
- 4 generations backK093831 Fully Automatic (Nibp) Blood Pressure Monitor, Model HL868RTHealth & Life Co., Ltd. · 2010
- 3 generations backK131121 Full Automatic (Nibp) Blood Pressure MonitorHealth & Life Co., Ltd. · 2013
- 2 generations backK142968 Full Automatic (NIBP) Blood Pressure MonitorHealth & Life Co., Ltd. · 2014
- 1 generation backK160145 Full Automatic (NIBP) Blood Pressure MonitorHealth & Life Co., Ltd. · 2016
- This deviceK190507 Full Automatic (NIBP) Blood Pressure MonitorHealth & Life Co., Ltd. · 2019
Most influential descendants
Showing 2 of 2 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −10 | K850316 | Unisonic Electronic Digital BP Monitor Ebm-2050 | Nihon Seimitsu Sokki Co., Ltd. | 1985 | — |
| −9 | K993890 | Digital Blood Pressure Monitor, Model DS-181 | Nihon Seimitsu Sokki Co., Ltd. | 1999 | — |
| −8 | K050697 | Model DS-1901 Digital Blood Pressure Monitor | Nihon Seimitsu Sokki Co., Ltd. | 2005 | — |
| −7 | K071384 | Modification to: Digital Blood Pressure Monitor, Model 1901 | Nihon Seimitsu Sokki Co., Ltd. | 2007 | — |
| −6 | K080177 | Wrist Blood Pressure Monitor, Model WS-1100/WS-1100PV | Nihon Seimitsu Sokki Co., Ltd. | 2008 | — |
| −5 | K092161 | Full Automatic (Nibp) Blood Pressure Monitor, Model HL868BF | Health & Life Co., Ltd. | 2009 | — |
| −4 | K093831 | Fully Automatic (Nibp) Blood Pressure Monitor, Model HL868RT | Health & Life Co., Ltd. | 2010 | — |
| −3 | K131121 | Full Automatic (Nibp) Blood Pressure Monitor | Health & Life Co., Ltd. | 2013 | — |
| −2 | K142968 | Full Automatic (NIBP) Blood Pressure Monitor | Health & Life Co., Ltd. | 2014 | — |
| −1 | K160145 | Full Automatic (NIBP) Blood Pressure Monitor | Health & Life Co., Ltd. | 2016 | — |
| 0 (this device) | K190507 | Full Automatic (NIBP) Blood Pressure Monitor | Health & Life Co., Ltd. | 2019 | — |
| +1 | K200437 | Blood Pressure Monitor | Shenzhen Jamr Technology Co., Ltd. | 2020 | — |
| +1 | K200521 | Full Automatic (NIBP) Blood Pressure Monitor | Health & Life Co., Ltd. | 2020 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1998 | 1 | 0 |
| 2000 | 1 | 0 |
| 2002 | 2 | 0 |
| 2004 | 2 | 0 |
| 2005 | 2 | 0 |
| 2006 | 3 | 0 |
| 2012 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2020 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DXN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DXN device
- #1 K222125 Arm Blood Pressure Monitor, models AOJ-30A…score 18.5 · 8 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K160145 | Full Automatic (NIBP) Blood Pressure MonitorSummary page 4…74 Cardiovascular Product Code: DXN 3. Information for the 510(k) Cleared Device (Predicate Device): Full Automatic (NIBP) Blood Pressure Monitor, Model: HL858CC (K160145) 5-1… | 2016 |
What descends from it? (2)
2 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 34 years and passes through 2 companies; a new generation was cleared every 2.5 years on median.
- 1 of the 22 ancestors has a recall of any class.
- Of its descendants, K200437 (Shenzhen Jamr Technology Co., Ltd., 2020) has gone furthest, with 0 descendants of its own.
How does its category compare?
All DXN devicesDXN System, Measurement, Blood-Pressure, Non-Invasive: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.
FDA decisions per year · DXN
28in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DXN
142in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DXN
3in 2024
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DXN
239in 2025
MAUDE reports naming product code DXN, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 27 | 118 | 0 | 21 |
| 2008 | 23 | 82 | 1 | 8 |
| 2009 | 46 | 73 | 3 | 17 |
| 2010 | 43 | 94 | 0 | 14 |
| 2011 | 34 | 72 | 1 | 10 |
| 2012 | 36 | 116 | 0 | 19 |
| 2013 | 34 | 150 | 1 | 72 |
| 2014 | 29 | 133 | 0 | 47 |
| 2015 | 30 | 97 | 0 | 62 |
| 2016 | 30 | 144 | 1 | 54 |
| 2017 | 33 | 184 | 0 | 90 |
| 2018 | 22 | 235 | 0 | 617 |
| 2019 | 33 | 156 | 1 | 96 |
| 2020 | 24 | 198 | 0 | 130 |
| 2021 | 23 | 190 | 0 | 162 |
| 2022 | 25 | 137 | 0 | 155 |
| 2023 | 35 | 182 | 0 | 162 |
| 2024 | 17 | 107 | 3 | 270 |
| 2025 | 28 | 142 | 0 | 239 |
| 2026 | 29 | 147 | 0 | — |
What is it indicated for?
HL858CL automatically measures human’s Systolic, Diastolic blood pressure and heart rate by using the oscillometric method during inflation. All values can be read out in one LCD panel. Measurement position is at human being’s upper arm. The intended use of this over-the-counter device is for adults aged 18 years and older with arm circumference ranging from 9 inches to 22 inches (approx.23 cm to 56 cm) and for home use. HL858CL detects the appearance of…
Read the full statement (162 words)
HL858CL automatically measures human’s Systolic, Diastolic blood pressure and heart rate by using the oscillometric method during inflation. All values can be read out in one LCD panel. Measurement position is at human being’s upper arm. The intended use of this over-the-counter device is for adults aged 18 years and older with arm circumference ranging from 9 inches to 22 inches (approx.23 cm to 56 cm) and for home use.
HL858CL detects the appearance of irregular heartbeats during measurement; an indicated symbol will appear with measuring reading. And the Risk Category Indicator will show the information with the readings on the screen for the user tracking their blood pressure level.
Besides, the device features a built-in "Bluetooth Data Transmission" function, which enables the device automatically transmit measuring results to paired Bluetooth-enabled device. Also, users could simply synchronize the current date and time, and check the battery status of blood pressure monitor by means of DailyChek® application software with the paired Bluetooth-enabled device.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K190507 · printed Nov 4, 2026
Cite this page
510(k) Report. “K190507: Full Automatic (NIBP) Blood Pressure Monitor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K190507
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026