Full Automatic (NIBP) Blood Pressure Monitor-HL158UB

K190133510(k) SpecialCleared Jun 13, 2019136-day reviewClass II21 CFR 870.1130

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Health & Life Co., Ltd. · DXN System, Measurement, Blood-Pressure, Non-Invasive

Cleared on Jun 13, 2019 as substantially equivalent to K162338 (Health & Life Co., Ltd., 2016) after a 136-day review. Its family tree reaches back 5 generations to 2005.

Decided
Jun 13, 2019
Review
136 days
Class
Class II
Product code
DXN
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to K042505 (2005). 7 ancestors in all, the oldest K003732 (2001). No later device cites it as a predicate yet.

  1. Root · 5 generations backK042505 Omron Digital Wrist Blood Pressure Monitor, Model Hem-609NOmron Healthcare, Inc. · 2005
  2. 4 generations backK123498 BP652N (Hem-6300-Z)Omron Healthcare, Inc. · 2013
  3. 3 generations backK142917 BP652N (Hem-6300-Z)Omron Healthcare, Inc. · 2014
  4. 2 generations backK160557 Full Automatic (NIBP) Blood Pressure MonitorHealth & Life Co., Ltd. · 2016
  5. 1 generation backK162338 Full Automatic (NIBP) Blood Pressure MonitorHealth & Life Co., Ltd. · 2016
  6. This deviceK190133 Full Automatic (NIBP) Blood Pressure Monitor-HL158UBHealth & Life Co., Ltd. · 2019
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K042505Omron Digital Wrist Blood Pressure Monitor, Model Hem-609NOmron Healthcare, Inc.2005—
−4K123498BP652N (Hem-6300-Z)Omron Healthcare, Inc.2013—
−3K142917BP652N (Hem-6300-Z)Omron Healthcare, Inc.2014—
−2K160557Full Automatic (NIBP) Blood Pressure MonitorHealth & Life Co., Ltd.2016—
−1K162338Full Automatic (NIBP) Blood Pressure MonitorHealth & Life Co., Ltd.2016—
0 (this device)K190133Full Automatic (NIBP) Blood Pressure Monitor-HL158UBHealth & Life Co., Ltd.2019—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200110
201010
FIG. 1 — Lineage of K190133, 2005–2019Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DXN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DXN device

  1. #1 K222125 Arm Blood Pressure Monitor, models AOJ-30A…score 18.5 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K162338Full Automatic (NIBP) Blood Pressure Monitor
Summary page 4
…iovascular Product Code: DXN 3. Information for the 510(k) Cleared Device (Predicate Device): Full Automatic (NIBP) Blood Pressure Monitor, Model: HL158UA (K162338) 4. Device Description: HL158UB automatically measures human’s Systolic, Diastolic blood pressure and heart rate by…
Health & Life Co., Ltd.2016—

Also cleared against K162338: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 14 years and passes through 2 companies; a new generation was cleared every 1.7 years on median.
  • None of the 7 ancestors has a recall.
  • 1 other device also cites its predicate K162338.

How does its category compare?

All DXN devices

DXN System, Measurement, Blood-Pressure, Non-Invasive: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.

FDA decisions per year · DXN

28in 2025

2007: 272008: 232009: 462010: 432011: 342012: 362013: 342014: 292015: 302016: 302017: 332018: 222019: 332020: 242021: 232022: 252023: 352024: 172025: 282026 (partial year): 29
2007high 46 (2009) · low 17 (2024)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DXN

142in 2025

2007: 118 days median2008: 82 days median2009: 73 days median2010: 94 days median2011: 72 days median2012: 116 days median2013: 150 days median2014: 133 days median2015: 97 days median2016: 144 days median2017: 184 days median2018: 235 days median2019: 156 days median2020: 198 days median2021: 190 days median2022: 137 days median2023: 182 days median2024: 107 days median2025: 142 days median2026 (partial year): 147 days median
2007high 235 (2018) · low 72 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DXN

3in 2024

2008: 12009: 32011: 12013: 12016: 12019: 12024: 3
2007high 3 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DXN

239in 2025

2007: 212008: 82009: 172010: 142011: 102012: 192013: 722014: 472015: 622016: 542017: 902018: 6172019: 962020: 1302021: 1622022: 1552023: 1622024: 2702025: 239
2007high 617 (2018) · low 8 (2008)2025

MAUDE reports naming product code DXN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200727118021
2008238218
20094673317
20104394014
20113472110
201236116019
201334150172
201429133047
20153097062
201630144154
201733184090
2018222350617
201933156196
2020241980130
2021231900162
2022251370155
2023351820162
2024171073270
2025281420239
2026291470—

What is it indicated for?

HL158UB automatically measures human’s Systolic, Diastolic blood pressure and heart rate by using the oscillometric method during inflation. All values can be read out in one LCD panel. Measurement position is at human being’s wrist. The intended use of this over-the-counter device is for adults aged 18 years and older with wrist circumference ranging from 5.3 inches to 7.7 inches (approx. 135 mm to 195 mm) and for home use. HL158UB detects the…

Read the full statement (110 words)

HL158UB automatically measures human’s Systolic, Diastolic blood pressure and heart rate by using the oscillometric

method during inflation. All values can be read out in one LCD panel. Measurement position is at human being’s wrist.

The intended use of this over-the-counter device is for adults aged 18 years and older with wrist circumference ranging

from 5.3 inches to 7.7 inches (approx. 135 mm to 195 mm) and for home use.

HL158UB detects the appearance of irregular heartbeats during measurement; an indicated symbol will appear with

measuring reading. And the Risk Category Indicator will show the information with the readings on the screen for the user

tracking their blood pressure level.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K190133: Full Automatic (NIBP) Blood Pressure Monitor-HL158UB.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K190133

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026