PrisMax System Version 2

K190910510(k) TraditionalCleared Jul 25, 2019108-day reviewClass II21 CFR 876.5860Recalls 5

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Baxter Healthcare Corp · KDI Dialyzer, High Permeability With Or Without Sealed Dialysate System

Cleared on Jul 25, 2019 as substantially equivalent to K171671 (Baxter Healthcare Corporation, 2018) and 1 other predicate after a 108-day review. Its family tree reaches back 2 generations to 2014. 2 later devices descend from it. It has been recalled 5 times.

Decided
Jul 25, 2019
Review
108 days
Class
Class II
Product code
KDI
Recalls
5
Predicates
2

Its longest line of descent runs back 2 generations to K131516 (2014). 3 ancestors in all. 2 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2018: 1 other ancestor2020: 1 descendant cleared2022: 1 descendant clearedK131516 · Prismaflex System 7.10 · Gambro Renal Products, Inc. · 2014 · recalledK163530 · PrisMax Control Unit · Baxter Healthcare Corp · 20172010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 2 descendants K163530 · PrisMax Control Unit · Baxter Healthcare Corp · 2017K131516 · Prismaflex System 7.10 · Gambro Renal Products, Inc. · 2014 · recalled0
  1. Root · 2 generations backK131516 Prismaflex System 7.10Gambro Renal Products, Inc. · 2014 · Recalled
  2. 1 generation backK163530 PrisMax Control UnitBaxter Healthcare Corp · 2017
  3. This deviceK190910 PrisMax System Version 2Baxter Healthcare Corp · 2019
  4. Descendant · cites it directly · 0 of its ownK212216 Prismaflex ST60 Set, Prismaflex ST100 Set, Prismaflex ST150 setBaxter Healthcare Corporation · 2022 · Recalled
  5. Descendant · cites it directly · 0 of its ownK193482 PrisMax System Version 3Baxter Healthcare Corporation · 2020 · Recalled

Most influential descendants

Showing 2 of 2 · See all
  • K212216Prismaflex ST60 Set, Prismaflex ST100 Set, Prismaflex ST150 setBaxter Healthcare Corporation · 2022 · cites it directly0descendants
  • K193482PrisMax System Version 3Baxter Healthcare Corporation · 2020 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K131516Prismaflex System 7.10Gambro Renal Products, Inc.20144
−1K163530PrisMax Control UnitBaxter Healthcare Corp2017—
0 (this device)K190910PrisMax System Version 2Baxter Healthcare Corp2019—
+1K212216Prismaflex ST60 Set, Prismaflex ST100 Set, Prismaflex ST150 setBaxter Healthcare Corporation20223
+1K193482PrisMax System Version 3Baxter Healthcare Corporation20202

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
201810

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202010
202210
FIG. 1 — Lineage of K190910, 2014–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KDI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KDI device

  1. #1 K243874 FX CorAL 60 (F00012969); FX CorAL 80…score 18.2 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K171671Prismaflex System 8.10
Summary page 4
…e(s) Device Company Predicate 510(k) Clearance Date Prismaflex 8.10 Baxter Healthcare, K171671 February 2018 BAXTER Confidential - Restricted: Do not distribute without prior approval…
Baxter Healthcare Corporation2018—
*K163530PrisMax Control Unit
Summary page 5
…Predicate 510(k) Clearance Date Gambro Lundia AB PrisMax 1.06 Baxter Healthcare, K163530 May 2016 Gambro UF Solutions DEVICE DESCRIPTION: The PrisMax System…
Baxter Healthcare Corp2017—

Also cleared against K171671: 1 other device →

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K212216Prismaflex ST60 Set, Prismaflex ST100 Set, Prismaflex ST150 setBaxter Healthcare Corporation20220
K193482PrisMax System Version 3Baxter Healthcare Corporation20200

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jul 28, 2025Class IIZ-2437-2025Under Investigation by firmLow deaeration chamber level at post priming tests may lead to PrisMax System alarm T2309: Air Detected in Prime resulting in multiple additional priming cycles
Jul 28, 2025Class IIZ-2439-2025Under Investigation by firmThermax System may be unable to detect the presence of a bag on the Thermax Blood Warmer Unit leading to difficulty setting up therapy, or PrisMax System alarm T2284: Thermax Disposable Not Inserted
Sep 29, 2021Class IIZ-0215-2022Software designIf the operator initiates therapy with a saved prescription profile and makes a change to the prescription after a disposable filter change using the Same Patient button, the system may suggest values from the original prescription…
Jan 7, 2021Class IIZ-1151-2021Under Investigation by firmVariability in the performance of the tubing in the ARPS (Automatic Repositioning System) Pump Assembly which may lead to alarm situations during system self-test and therapy. This tubing is normally replaced during annual preventative…
Sep 19, 2019Class IIZ-0247-2020Device DesignTherMax Blood Warmers may not be in compliance with an electrical safety standard, which requires a protective earth connection that can sustain a current of 25 amps for 10 seconds.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 5 years and passes through 2 companies; a new generation was cleared every 3.3 years on median.
  • 1 of the 3 ancestors has a recall of any class.
  • Of its descendants, K212216 (Baxter Healthcare Corporation, 2022) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K171671.

How does its category compare?

All KDI devices

KDI Dialyzer, High Permeability With Or Without Sealed Dialysate System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.

FDA decisions per year · KDI

9in 2025

2007: 112008: 62009: 42010: 92011: 52012: 62013: 112014: 82015: 52016: 52017: 82018: 22019: 42020: 92021: 22022: 72023: 72024: 72025: 92026 (partial year): 6
2007high 11 (2007) · low 2 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KDI

199in 2025

2007: 91 days median2008: 148 days median2009: 236 days median2010: 186 days median2011: 85 days median2012: 153 days median2013: 247 days median2014: 164 days median2015: 69 days median2016: 230 days median2017: 188 days median2019: 263 days median2020: 266 days median2022: 259 days median2023: 157 days median2024: 235 days median2025: 199 days median2026 (partial year): 154 days median
2007high 266 (2020) · low 69 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KDI

2in 2025

2007: 42009: 32010: 12011: 42012: 12013: 22014: 32015: 52016: 42017: 12018: 12019: 62021: 22022: 172023: 8, 8 Class I2024: 4, 2 Class I2025: 22026 (partial year): 2
2007high 17 (2022) · low 0 (2008)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · KDI

2,786in 2025

2007: 9162008: 1,0422009: 5222010: 8232011: 2,2702012: 1,7652013: 2,3602014: 6,1542015: 4,1822016: 7662017: 9632018: 1,7162019: 1,5872020: 1,6332021: 1,9442022: 2,1802023: 2,6922024: 2,4412025: 2,786
2007high 6,154 (2014) · low 522 (2009)2025

MAUDE reports naming product code KDI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200711914916
2008614801,042
200942363522
201091861823
201158542,270
2012615311,765
20131124722,360
2014816436,154
201556954,182
201652304766
201781881963
20182—11,716
2019426361,587
2020926601,633
20212—21,944
20227259172,180
202371578 (8)2,692
202472354 (2)2,441
2025919922,786
202661542—

What is it indicated for?

The PrisMax control unit is intended for:

• Continuous Renal Replacement Therapy (CRRT) for patients weighing 20 kilograms or more with acute renal failure and/or fluid overload.

• Therapeutic Plasma Exchange (TPE) therapy for patients weighing 20 kilograms or more with diseases where removal of plasma components is indicated.

All treatments administered via the PrisMax control unit must be prescribed by a physician.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K190910: PrisMax System Version 2.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K190910

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026