510(k) · Cleared
ClearedAVIEW Modeler
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Coreline Soft Co., Ltd. · LLZ System, Image Processing, Radiological
Cleared on Dec 20, 2019 as substantially equivalent to K161841 (3D Systems, Inc., 2017) after a 142-day review. Its family tree reaches back 5 generations to 1993.
- Decided
- Dec 20, 2019
- Review
- 142 days
- Class
- Class II
- Product code
- LLZ
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 5 generations to K924630 (1993). 6 ancestors in all, the oldest K924810 (1993). No later device cites it as a predicate yet.
- Root · 5 generations backK924630 Surgicad (TM) View (TM)Surgicad Corp. · 1993
- 4 generations backK970617 CT-Modeller SystemMaterialise NV · 1997
- 3 generations backK033849 Simplant SystemMaterialise NV · 2004
- 2 generations backK073468 MimicsMaterialise NV · 2008
- 1 generation backK161841 D2P3D Systems, Inc. · 2017
- This deviceK192040 AVIEW ModelerCoreline Soft Co., Ltd. · 2019
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −5 | K924630 | Surgicad (TM) View (TM) | Surgicad Corp. | 1993 | — |
| −4 | K970617 | CT-Modeller System | Materialise NV | 1997 | — |
| −3 | K033849 | Simplant System | Materialise NV | 2004 | — |
| −2 | K073468 | Mimics | Materialise NV | 2008 | — |
| −1 | K161841 | D2P | 3D Systems, Inc. | 2017 | — |
| 0 (this device) | K192040 | AVIEW Modeler | Coreline Soft Co., Ltd. | 2019 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1993 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LLZ device
- #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K161841 | D2PSummary page 4…Modeler Classification Name: System, image processing, radiological (21CFR 892.2050) Regulatory Class: II Product Code: LLZ 3 PREDICATE DEVICE D2P by 3D Systems, Inc. (K161841) This predicate has not been subject to a design-related recall 4 REFERENCE DEVICE Mimics inPrint by Materialise N.V. (K173619)… | 2017 |
| † | K173619 | Mimics inPrint | 2018 |
| † | K171199 | AVIEW | 2018 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 26 years and passes through 4 companies; a new generation was cleared every 4.0 years on median.
- None of the 6 ancestors has a recall.
- 1 other device also cites its predicate K161841.
How does its category compare?
All LLZ devicesLLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.
FDA decisions per year · LLZ
58in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LLZ
173in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LLZ
11in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LLZ
116in 2025
MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 76 | 36 | 20 | 152 |
| 2008 | 94 | 52 | 32 | 154 |
| 2009 | 70 | 62 | 21 | 145 |
| 2010 | 51 | 98 | 17 | 145 |
| 2011 | 106 | 79 | 30 | 454 |
| 2012 | 82 | 87 | 12 | 266 |
| 2013 | 95 | 84 | 64 | 1,130 |
| 2014 | 78 | 89 | 6 | 15,631 |
| 2015 | 64 | 90 | 16 | 211 |
| 2016 | 82 | 90 | 12 | 290 |
| 2017 | 78 | 107 | 5 | 104 |
| 2018 | 104 | 105 | 7 | 72 |
| 2019 | 74 | 107 | 2 | 88 |
| 2020 | 81 | 115 | 6 | 82 |
| 2021 | 83 | 116 | 3 | 70 |
| 2022 | 65 | 137 | 4 | 28 |
| 2023 | 87 | 157 | 8 | 26 |
| 2024 | 62 | 131 | 6 | 42 |
| 2025 | 58 | 173 | 11 | 116 |
| 2026 | 45 | 110 | 14 | — |
What is it indicated for?
The AVIEW Modeler is intended for use as an image review and segmentation system that operates on DICOM imaging information obtained from a medical scanner. It is also used as a pre-operative software for surgical planning.
3D printed models generated from the output file are for visualization and educational purposes only and not for diagnostic use.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K192040 · printed Nov 6, 2026
Cite this page
510(k) Report. “K192040: AVIEW Modeler.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K192040
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026