ClearedAina HbA1c Monitoring System 2
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Jana Care, Inc. · LCP Assay, Glycosylated Hemoglobin
Cleared on Mar 26, 2020 as substantially equivalent to K151809 (Alere Technologies AS, 2015) after a 153-day review. Its family tree reaches back 4 generations to 1995.
- Decided
- Mar 26, 2020
- Review
- 153 days
- Class
- Class II
- Product code
- LCP
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 4 generations to K951361 (1995). No later device cites it as a predicate yet.
- Root · 4 generations backK951361 Dca 2000 System for Hemoglobin A1CHeraeus Kulzer, Inc. · 1995 · Recalled
- 3 generations backK050574 Afinion HbalcAxis-Shield Poc AS · 2005
- 2 generations backK110056 Afinion AnalyzerAxis-Shield Poc AS · 2011
- 1 generation backK151809 Alere Afinion HbA1c, Alere Afinion AS100 AnalyzerAlere Technologies AS · 2015
- This deviceK192987 Aina HbA1c Monitoring System 2Jana Care, Inc. · 2020
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K951361 | Dca 2000 System for Hemoglobin A1C | Heraeus Kulzer, Inc. | 1995 | 1 |
| −3 | K050574 | Afinion Hbalc | Axis-Shield Poc AS | 2005 | — |
| −2 | K110056 | Afinion Analyzer | Axis-Shield Poc AS | 2011 | — |
| −1 | K151809 | Alere Afinion HbA1c, Alere Afinion AS100 Analyzer | Alere Technologies AS | 2015 | — |
| 0 (this device) | K192987 | Aina HbA1c Monitoring System 2 | Jana Care, Inc. | 2020 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LCP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LCP device
- #1 K221326 Nova Allegro HbA1c Assay, Nova Allegro Analyzerscore 9.6 · 5 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K151809 | Alere Afinion HbA1c, Alere Afinion AS100 AnalyzerSummary page 4…n HbA1c, Afinion AS100 Analyzer Characteristic Aina HbA1c Monitoring System 2 K151809 (New Device) (Pred… | 2015 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 25 years and passes through 4 companies; a new generation was cleared every 5.6 years on median.
- 1 of the 4 ancestors has a recall of any class.
- 4 other devices also cite its predicate K151809.
How does its category compare?
All LCP devicesLCP Assay, Glycosylated Hemoglobin: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.
FDA decisions per year · LCP
1in 2024
2026 to Oct 25, outlined.
Median 510(k) review, days · LCP
269in 2019
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LCP
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LCP
22in 2025
MAUDE reports naming product code LCP, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 7 | 133 | 1 | 5 |
| 2008 | 5 | 206 | 3 | 11 |
| 2009 | 6 | 158 | 6 | 15 |
| 2010 | 2 | — | 5 | 4 |
| 2011 | 10 | 176 | 51 | 27 |
| 2012 | 9 | 143 | 0 | 51 |
| 2013 | 2 | — | 4 | 193 |
| 2014 | 8 | 127 | 2 | 182 |
| 2015 | 3 | 239 | 2 | 64 |
| 2016 | 2 | — | 6 | 29 |
| 2017 | 5 | 218 | 1 | 149 |
| 2018 | 2 | — | 1 | 1,911 |
| 2019 | 4 | 269 | 0 | 114 |
| 2020 | 1 | — | 0 | 13 |
| 2021 | 0 | — | 0 | 7 |
| 2022 | 0 | — | 1 | 8 |
| 2023 | 2 | — | 0 | 27 |
| 2024 | 1 | — | 1 | 39 |
| 2025 | 0 | — | 1 | 22 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The Aina HbA1c Monitoring System 2 consists of the Aina 2 Automated HbA1c Device, the Aina Device, Aina HbA1c Test Kits, mobile device, and the Aina Mobile Application. It is intended to be used for quantitative measurement of %HbA1c (DCCT/NGSP) and mmol/mol HbA1c (IFCC) in human anticoagulated venous whole blood. It is intended for in-vitro diagnostic use by healthcare professionals in a laboratory environment to monitor long term glycemic control of persons previously diagnosed with diabetes. This test is not intended for use in the diagnosis of or screening for diabetes or for use on neonates.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K192987 · printed Nov 5, 2026
Cite this page
510(k) Report. “K192987: Aina HbA1c Monitoring System 2.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K192987