510(k) · Cleared
ClearedATTUNE All-Polyethylene Tibia
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Depuy Ireland UC · JWH Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
Cleared on Jan 30, 2020 as substantially equivalent to K943462 (Johnson & Johnson Professionals, Inc., 1994) and 4 other predicates after a 90-day review. Its family tree reaches back 4 generations to 1994.
- Decided
- Jan 30, 2020
- Review
- 90 days
- Class
- Class II
- Product code
- JWH
- Recalls
- None
- Predicates
- 5
Its longest line of descent runs back 4 generations to K943462 (1994). 11 ancestors in all, the oldest K922620 (1992). No later device cites it as a predicate yet.
- Root · 4 generations backK943462 Darwin Knee SystemJohnson & Johnson Professionals, Inc. · 1994 · Recalled
- 3 generations backK033272 Depuy Sigma Tibial InsertsDePuy Orthopaedics, Inc. · 2004 · Recalled
- 2 generations backK040166 Depuy Sigma XLK Tibial InsertsDePuy Orthopaedics, Inc. · 2004
- 1 generation backK101433 Depuy Attune Knee SystemDePuy Orthopaedics, Inc. · 2010
- This deviceK193057 ATTUNE All-Polyethylene TibiaDepuy Ireland UC · 2020
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K943462 | Darwin Knee System | Johnson & Johnson Professionals, Inc. | 1994 | 8 |
| −3 | K033272 | Depuy Sigma Tibial Inserts | DePuy Orthopaedics, Inc. | 2004 | 51 |
| −2 | K040166 | Depuy Sigma XLK Tibial Inserts | DePuy Orthopaedics, Inc. | 2004 | — |
| −1 | K101433 | Depuy Attune Knee System | DePuy Orthopaedics, Inc. | 2010 | — |
| 0 (this device) | K193057 | ATTUNE All-Polyethylene Tibia | Depuy Ireland UC | 2020 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1992 | 1 | 0 |
| 1995 | 2 | 0 |
| 1996 | 1 | 0 |
| 1997 | 1 | 0 |
| 2003 | 1 | 0 |
| 2008 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JWH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JWH device
- #1 K221479 Persona Personalized Knee Systemscore 22.4 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (5)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K943462 | Darwin Knee SystemSummary page 4…s II Classification panel 87 Orthopedics Regulation 21 CFR 888.3560 Product Code(s) JWH Legally marketed device(s) to which equivalence is claimed Darwin Knee System, K943462 Darwin Knee System (Cruciate-Substituting) Porous Coated and Non- Porous Coated, K950010 P.F.C. Cruciate Retaining Knee System… | 1994 |
| * | K950010 | Darwin Knee System (Cruciate Substituting) Porous Coated and Non-Porous CoatedSummary page 4…Legally marketed device(s) to which equivalence is claimed Darwin Knee System, K943462 Darwin Knee System (Cruciate-Substituting) Porous Coated and Non- Porous Coated, K950010 P.F.C. Cruciate Retaining Knee System (Size 1.5), K961685 P.F.C. Sigma Knee System (Size 1.5), K971189 DePuy ATTUNE Knee Syste… | 1995 |
| * | K961685 | P.F.C. Cruciate Retaining Knee System (Size 1.5)Summary page 4…Darwin Knee System, K943462 Darwin Knee System (Cruciate-Substituting) Porous Coated and Non- Porous Coated, K950010 P.F.C. Cruciate Retaining Knee System (Size 1.5), K961685 P.F.C. Sigma Knee System (Size 1.5), K971189 DePuy ATTUNE Knee System, K101433 Reason for 510(k) submission This 510(k) submi… | 1996 |
| * | K971189 | P.F.C. Sigma Knee System (Size 1.5)Summary page 4…em (Cruciate-Substituting) Porous Coated and Non- Porous Coated, K950010 P.F.C. Cruciate Retaining Knee System (Size 1.5), K961685 P.F.C. Sigma Knee System (Size 1.5), K971189 DePuy ATTUNE Knee System, K101433 Reason for 510(k) submission This 510(k) submission is to add the ATTUNE All Polyethylene Ti… | 1997 |
| * | K101433 | Depuy Attune Knee SystemSummary page 4…oated and Non- Porous Coated, K950010 P.F.C. Cruciate Retaining Knee System (Size 1.5), K961685 P.F.C. Sigma Knee System (Size 1.5), K971189 DePuy ATTUNE Knee System, K101433 Reason for 510(k) submission This 510(k) submission is to add the ATTUNE All Polyethylene Tibia to the currently cleared ATTUNE… | 2010 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 26 years and passes through 3 companies; a new generation was cleared every 9.1 years on median.
- 6 of the 11 ancestors have a recall of any class.
- 11 other devices also cite its predicate K943462.
How does its category compare?
All JWH devicesJWH Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.
FDA decisions per year · JWH
20in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JWH
55in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JWH
2in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JWH
9,306in 2025
MAUDE reports naming product code JWH, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 18 | 74 | 14 | 1,305 |
| 2008 | 17 | 81 | 10 | 1,483 |
| 2009 | 11 | 168 | 109 | 1,870 |
| 2010 | 19 | 85 | 32 | 3,286 |
| 2011 | 25 | 87 | 27 | 5,133 |
| 2012 | 33 | 85 | 85 | 5,203 |
| 2013 | 31 | 128 | 31 | 6,135 |
| 2014 | 33 | 98 | 13 | 6,722 |
| 2015 | 27 | 87 | 11 | 6,881 |
| 2016 | 18 | 88 | 17 | 7,586 |
| 2017 | 25 | 118 | 61 | 12,263 |
| 2018 | 25 | 90 | 14 | 14,071 |
| 2019 | 28 | 133 | 5 | 14,987 |
| 2020 | 22 | 59 | 2 | 12,592 |
| 2021 | 24 | 61 | 8 | 9,408 |
| 2022 | 17 | 56 | 12 | 8,364 |
| 2023 | 20 | 57 | 67 | 8,947 |
| 2024 | 19 | 89 | 7 | 10,828 |
| 2025 | 20 | 55 | 2 | 9,306 |
| 2026 | 12 | 63 | 4 | — |
What is it indicated for?
Candidates for total knee replacement include patients with a severely painful and/or severely disabled joint resulting
from osteoarthritis, post-traumatic arthritis, rheumatoid arthritis, or a failed previous implant.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K193057 · printed Nov 6, 2026
Cite this page
510(k) Report. “K193057: ATTUNE All-Polyethylene Tibia.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K193057
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026