iCTmotor (WL-1)

K193341510(k) TraditionalCleared Sep 4, 2020276-day reviewClass I21 CFR 872.4200

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Dentium Co., Ltd. · EBW Controller, Foot, Handpiece And Cord

Cleared on Sep 4, 2020 as substantially equivalent to K140308 (Kaltenbach & Voigt GmbH, 2014) after a 276-day review. Its family tree reaches back 4 generations to 2001.

Decided
Sep 4, 2020
Review
276 days
Class
Class I
Product code
EBW
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K002469 (2001). 6 ancestors in all, the oldest K970953 (1997). No later device cites it as a predicate yet.

  1. Root · 4 generations backK002469 Implantmed SI-95 115 (100-130 V) and SI-95 230 (220-240 V)W&H Dentalwerk Buermoos GmbH · 2001
  2. 3 generations backK052741 Implantmed SI-915 (115V Version); Implantmed SI-923 (230V Version)…W&H Dentalwerk Buermoos GmbH · 2006
  3. 2 generations backK092214 Chiropro L SystemBien-Air Dental, SA · 2009 · Recalled
  4. 1 generation backK140308 Mastersurg / ExpertsurgKaltenbach & Voigt GmbH · 2014
  5. This deviceK193341 iCTmotor (WL-1)Dentium Co., Ltd. · 2020
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K002469Implantmed SI-95 115 (100-130 V) and SI-95 230 (220-240 V)W&H Dentalwerk Buermoos GmbH2001—
−3K052741Implantmed SI-915 (115V Version); Implantmed SI-923 (230V Version) Incl.…W&H Dentalwerk Buermoos GmbH2006—
−2K092214Chiropro L SystemBien-Air Dental, SA20091
−1K140308Mastersurg / ExpertsurgKaltenbach & Voigt GmbH2014—
0 (this device)K193341iCTmotor (WL-1)Dentium Co., Ltd.2020—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199710
200110
FIG. 1 — Lineage of K193341, 2001–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in EBW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new EBW device

  1. #1 K251701 Star E900 Electric Systemscore 12.2 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K140308Mastersurg / Expertsurg
Summary page 4
…ation Number 21 CFR 872.4200 Product Code EBW Regulatory Class Class I III. PRIMARY PREDICATE DEVICE (K140308) Primary Manufacturer Kaltenbach & Voigt GmbH Device Name MASTERsurg / EXPERTsurg…
Kaltenbach & Voigt GmbH2014—

Also cleared against K140308: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 19 years and passes through 4 companies; a new generation was cleared every 4.9 years on median.
  • 1 of the 6 ancestors has a recall of any class.
  • 1 other device also cites its predicate K140308.

How does its category compare?

All EBW devices

EBW Controller, Foot, Handpiece And Cord: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.

FDA decisions per year · EBW

3in 2025

2009: 52010: 12011: 32012: 12013: 12014: 32015: 12016: 12017: 42018: 12019: 22020: 12021: 22022: 62024: 42025: 32026 (partial year): 3
2007high 6 (2022) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · EBW

220in 2025

2009: 112 days median2011: 226 days median2014: 189 days median2017: 227 days median2022: 479 days median2024: 268 days median2025: 220 days median2026 (partial year): 269 days median
2007high 479 (2022) · low 112 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · EBW

1in 2013

2013: 1
2007high 1 (2013) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · EBW

13in 2025

2009: 162010: 182011: 12012: 52013: 12014: 42015: 132016: 62017: 132018: 462019: 552020: 712021: 572022: 312023: 172024: 142025: 13
2007high 71 (2020) · low 0 (2007)2025

MAUDE reports naming product code EBW, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20095112016
20101—018
2011322601
20121—05
20131—11
2014318904
20151—013
20161—06
20174227013
20181—046
20192—055
20201—071
20212—057
20226479031
20230—017
20244268014
20253220013
202632690—

What is it indicated for?

iCTmotor (WL-1) is intended for use in dental surgery and implantology. The main control unit is designed to operate a specific dental micro motor that drives dental handpieces to cut hard and soft tissues in the mouth and screw dental implants. iCTmotor (WL-1) is compatible with a handpiece equipped with connection according to ISO 3964.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K193341: iCTmotor (WL-1).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K193341

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026