Stat Profile Prime Plus Analyzer System

K200204510(k) TraditionalCleared Apr 6, 202069-day reviewClass II21 CFR 864.7500

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Nova Biomedical Corporation · GGZ Oxyhemoglobin

Cleared on Apr 6, 2020 as substantially equivalent to K180186 (Nova Biomedical Corporation, 2018) after a 69-day review. Its family tree reaches back 3 generations to 2006.

Decided
Apr 6, 2020
Review
69 days
Class
Class II
Product code
GGZ
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K061830 (2006). No later device cites it as a predicate yet.

  1. Root · 3 generations backK061830 Stat Profile Critical Care Xpress (CCX), Model 1+Nova Biomedical Corp. · 2006
  2. 2 generations backK110648 Nova Stat Profile Phox Ultra Analyzer SystemNova Biomedical Corporation · 2011
  3. 1 generation backK180186 Stat Profile Prime Plus Analyzer SystemNova Biomedical Corporation · 2018
  4. This deviceK200204 Stat Profile Prime Plus Analyzer SystemNova Biomedical Corporation · 2020
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K061830Stat Profile Critical Care Xpress (CCX), Model 1+Nova Biomedical Corp.2006—
−2K110648Nova Stat Profile Phox Ultra Analyzer SystemNova Biomedical Corporation2011—
−1K180186Stat Profile Prime Plus Analyzer SystemNova Biomedical Corporation2018—
0 (this device)K200204Stat Profile Prime Plus Analyzer SystemNova Biomedical Corporation2020—
FIG. 1 — Lineage of K200204, 2006–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GGZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K180186Stat Profile Prime Plus Analyzer System
Summary page 4
…Class II GHS 21 CFR § 864.5620 Automated hemoglobin system Class II GKR Predicate Device: k180186 – Stat Profile Prime Plus Analyzer System Device Description: The Stat Profile Prime Plus Analyzer System is a low cost,…
Nova Biomedical Corporation2018—
*—Nova Stat Profile pHOx Ultra Analyzer System
Named without a submission number
—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 14 years and passes through 2 companies; a new generation was cleared every 4.8 years on median.
  • None of the 3 ancestors has a recall.

How does its category compare?

All GGZ devices

GGZ Oxyhemoglobin: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.

FDA decisions per year · GGZ

1in 2020

2018: 12020: 1
2007high 1 (2018) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GGZ

Too few GGZ 510(k)s in any year since 2007 to give a median.

Recalls per year · GGZ

No recall names GGZ since 2007.

Adverse event reports per year · GGZ

No MAUDE report names GGZ since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20181—00
20190—00
20201—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

The Stat Profile Prime Plus Analyzer System is indicated for use by healthcare professionals in clinical laboratory settings and for point-of-care usage for quantitative determination of Hematocrit, Oxygen Saturation, Total Hemoglobin, Oxyhemoglobin, Carboxyhemoglobin, Methemoglobin, and Deoxyhemoglobin in heparinized arterial and venous whole blood. Hematocrit (Hct) measurements of the packed red blood cell volume are used to distinguish normal from…

Read the full statement (230 words)

The Stat Profile Prime Plus Analyzer System is indicated for use by healthcare professionals in clinical laboratory settings and for point-of-care usage for quantitative determination of Hematocrit, Oxygen Saturation, Total Hemoglobin, Oxyhemoglobin, Carboxyhemoglobin, Methemoglobin, and Deoxyhemoglobin in heparinized arterial and venous whole blood.

Hematocrit (Hct) measurements of the packed red blood cell volume are used to distinguish normal from abnormal states, such as anemia and erythrocytosis.

Oxygen Saturation (SO2) measurements are used to assess the oxygenation of the hemoglobin and the adequacy of tissue oxygenation in the evaluation of pulmonary function. Measurements are also used to diagnose and treat cyanosis.

Total Hemoglobin (tHb) measurements are used in the evaluation of chronic and acute anemia as well as the oxygen transport capability of the hemoglobin.

Oxyhemoglobin (O2Hb) measurements are used to assess pulmonary function in combination with Deoxyhemoglobin and are also used in the diagnosis and treatment of cyanosis.

Carboxyhemoglobin (COHb) measurements are used to determine if and to what level carbon monoxide has been inhaled by the patient. High levels of carbon monoxide can lead to tissue anoxia and death.

Methemoglobin (MetHb) measurements are used to determine congenital methemoglobinemia or determine the ingestion of nitrates, chlorates, or any other drug or chemical that can cause methemoglobin formation. High levels of methemoglobin can lead to cyanosis and death.

Deoxyhemoglobin (HHb) measurements are used to assess pulmonary function in combination with Oxyhemoglobin.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K200204: Stat Profile Prime Plus Analyzer System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K200204

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026