510(k) Report

510(k) · Cleared

Cleared

Reprocessed Advisor HD Grid Mapping Catheter, Sensor Enabled

K200212510(k) TraditionalCleared Sep 3, 2020219-day reviewClass II21 CFR 870.1220

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Innovative Health, LLC · MTD Catheter, Intracardiac Mapping, High-Density Array

Cleared on Sep 3, 2020 as substantially equivalent to K172393 (St. Jude Medical, Inc., 2018) after a 219-day review. Its family tree reaches back 6 generations to 1999. 1 later device descends from it.

Decided
Sep 3, 2020
Review
219 days
Class
Class II
Product code
MTD
Recalls
None
Predicates
1

Its longest line of descent runs back 6 generations to K983171 (1999). 17 ancestors in all, the oldest K961924 (1997). 1 later device descends from it, 1 citing it directly.

  1. Root · 6 generations backK983171 Constellation Multiple Electrode Pacing and Recording SystemBoston Scientific Corp · 1999 · Recalled
  2. 5 generations backK992777 Constellation Catheters, Model 8039Boston Scientific Corp · 1999 · Recalled
  3. 4 generations backK021232 Constellation Catheters, Model 8031MBoston Scientific Corp · 2002 · Recalled
  4. 3 generations backK050217 Flower High-Density Mapping Catheter, 4-4-4 MM Electrode Spacing)…Biosense Webster, Inc. · 2005
  5. 2 generations backK120425 Pentaray Nav High-Density Mapping CatheterBiosense Webster, Inc. · 2012 · Recalled
  6. 1 generation backK172393 Advisor HD Grid Mapping Catheter, Sensor EnabledSt. Jude Medical, Inc. · 2018
  7. This deviceK200212 Reprocessed Advisor HD Grid Mapping Catheter, Sensor EnabledInnovative Health, LLC · 2020
  8. Descendant · cites it directly · 0 of its ownK212776 Reprocessed Advisor HD Grid Mapping Catheter, Sensor EnabledInnovative Health, LLC · 2021

Most influential descendants

Showing 1 of 1 · See all
  • K212776Reprocessed Advisor HD Grid Mapping Catheter, Sensor EnabledInnovative Health, LLC · 2021 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K983171Constellation Multiple Electrode Pacing and Recording SystemBoston Scientific Corp19991
−5K992777Constellation Catheters, Model 8039Boston Scientific Corp19991
−4K021232Constellation Catheters, Model 8031MBoston Scientific Corp20021
−3K050217Flower High-Density Mapping Catheter, 4-4-4 MM Electrode Spacing), (2-6-2 MM…Biosense Webster, Inc.2005—
−2K120425Pentaray Nav High-Density Mapping CatheterBiosense Webster, Inc.20125
−1K172393Advisor HD Grid Mapping Catheter, Sensor EnabledSt. Jude Medical, Inc.2018—
0 (this device)K200212Reprocessed Advisor HD Grid Mapping Catheter, Sensor EnabledInnovative Health, LLC2020—
+1K212776Reprocessed Advisor HD Grid Mapping Catheter, Sensor EnabledInnovative Health, LLC2021—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199720
199810
200020
200130
200410
201010
201610

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202110
FIG. 1 — Lineage of K200212, 1999–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MTD? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MTD device

  1. #1 K231312 PENTARAY® NAV ECO High Density Mapping…score 16.4 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K172393Advisor HD Grid Mapping Catheter, Sensor Enabled
Summary page 5
…Product Code: NLG Predicate Device: 510(k) Number Device Manufacturer K172393 Advisor HD Grid Mapping Catheter, Sensor St. Jude Medical Enabled Ref…
St. Jude Medical, Inc.2018—
†K181458Reprocessed Advisor FL Sensor Enabled Circular Mapping CatheterInnovative Health, LLC2018—
†K190785Reprocessed PentaRay Nav eco High-Density Mapping CatheterInnovative Health, LLC2019—

Also cleared against K172393: 3 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K212776Reprocessed Advisor HD Grid Mapping Catheter, Sensor EnabledInnovative Health, LLC20210

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 21 years and passes through 4 companies; a new generation was cleared every 2.9 years on median.
  • 8 of the 17 ancestors have a recall of any class.
  • Of its descendants, K212776 (Innovative Health, LLC, 2021) has gone furthest, with 0 descendants of its own.
  • 3 other devices also cite its predicate K172393.

How does its category compare?

All MTD devices

MTD Catheter, Intracardiac Mapping, High-Density Array: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.

FDA decisions per year · MTD

2in 2024

2012: 22013: 22014: 22016: 12017: 22018: 12020: 42021: 12022: 22023: 32024: 22026 (partial year): 2
2007high 4 (2020) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MTD

66in 2023

2020: 169 days median2023: 66 days median
2007high 169 (2020) · low 66 (2023)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MTD

2in 2017

2017: 2
2007high 2 (2017) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MTD

385in 2025

2007: 12008: 32009: 62010: 192011: 142012: 172013: 302014: 282015: 362016: 352017: 382018: 492019: 772020: 872021: 992022: 1452023: 1842024: 3782025: 385
2007high 385 (2025) · low 1 (2007)2025

MAUDE reports naming product code MTD, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—01
20080—03
20090—06
20100—019
20110—014
20122—017
20132—030
20142—028
20150—036
20161—035
20172—238
20181—049
20190—077
20204169087
20211—099
20222—0145
20233660184
20242—0378
20250—0385
20262—0—

What is it indicated for?

The Reprocessed Advisor HD Grid Mapping Catheter, Sensor Enabled, is indicated for multiple electrode electrophysiological mapping of cardiac structures in the heart, i.e., recording or stimulation only. This catheter is intended to obtain electrograms in the atrial and ventricular regions of the heart.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K200212: Reprocessed Advisor HD Grid Mapping Catheter, Sensor Enabled.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K200212

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026