Becker External Drainage and Monitoring System

K200456510(k) SpecialCleared Mar 26, 202030-day reviewClass II21 CFR 882.1620Recalls 2 (2 Class I)

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Medtronic, Inc. · GWM Device, Monitoring, Intracranial Pressure

Cleared on Mar 26, 2020 as substantially equivalent to K984053 (Medtronic PS Medical, 1999) after a 30-day review. Its family tree reaches back 2 generations to 1990. 2 of the 5 devices in its family, counting itself, have a Class I recall. 1 later device descends from it. It has been recalled 2 times, including 2 Class I recalls.

Decided
Mar 26, 2020
Review
30 days
Class
Class II
Product code
GWM
Recalls
2 (2 Class I)
Predicates
1

Its longest line of descent runs back 2 generations to K902257 (1990). 3 ancestors in all. 1 later device descends from it, 1 citing it directly. 2 of the 5 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 1991: 1 other ancestor2025: 1 descendant clearedK902257 · Codman* External Drainage System II (Eds-II) · Codman & Shurtleff, Inc. · 1990K984053 · Becker External Drainage and Monitoring System · Medtronic PS Medical · 1999 · Class I recall1990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 1 other ancestor 1 generation forward: 1 descendant K984053 · Becker External Drainage and Monitoring System · Medtronic PS Medical · 1999 · Class I recallK902257 · Codman* External Drainage System II (Eds-II) · Codman & Shurtleff, Inc. · 19900
  1. Root · 2 generations backK902257 Codman* External Drainage System II (Eds-II)Codman & Shurtleff, Inc. · 1990
  2. 1 generation backK984053 Becker External Drainage and Monitoring SystemMedtronic PS Medical · 1999 · Recalled (Class I)
  3. This deviceK200456 Becker External Drainage and Monitoring SystemMedtronic, Inc. · 2020
  4. Descendant · cites it directly · 0 of its ownK243676 Duet External Drainage and Monitoring System (EDMS)Medtronic Neurosurgery · 2025

Class I recalls in this family

Most influential descendants

Showing 1 of 1 · See all
  • K243676Duet External Drainage and Monitoring System (EDMS)Medtronic Neurosurgery · 2025 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K902257Codman* External Drainage System II (Eds-II)Codman & Shurtleff, Inc.1990—
−1K984053Becker External Drainage and Monitoring SystemMedtronic PS Medical1999Class I
0 (this device)K200456Becker External Drainage and Monitoring SystemMedtronic, Inc.2020—
+1K243676Duet External Drainage and Monitoring System (EDMS)Medtronic Neurosurgery2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199110

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202510
FIG. 1 — Lineage of K200456, 1990–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GWM device

  1. #1 K252241 Pressio 3 Multi-parameter Neuromonitoring Systemscore 12.9 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K984053Becker External Drainage and Monitoring System
Summary page 6
…Subject Device Predicate Device K984053 Intended use / Draining and monitoring of CSF flow Draining and monitoring of CSF flow from Indications for from the…
Medtronic PS Medical1999Class I

Also cleared against K984053: 4 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K243676Duet External Drainage and Monitoring System (EDMS)Medtronic Neurosurgery20250

Has anything in its family been recalled? (2 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Nov 1, 2024Class IZ-0661-2025Under Investigation by firmDue to complaints received reporting cracks and/or leaks of the stopcocks associated with the external drainage and monitoring system (EDMS).
Nov 1, 2024Class IZ-0662-2025Under Investigation by firmDue to complaints received reporting cracks and/or leaks of the stopcocks associated with the external drainage and monitoring system (EDMS).

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K984053Becker External Drainage and Monitoring SystemMedtronic PS Medical · 1999 · Direct predicate · ◆ on the line of descent in FIG. 15 Class I recalls

What does this lineage say?

  • The line of descent spans 30 years and passes through 3 companies; a new generation was cleared every 21.1 years on median.
  • 1 of the 3 ancestors has a recall of any class; 1 has a Class I recall.
  • Of its descendants, K243676 (Medtronic Neurosurgery, 2025) has gone furthest, with 0 descendants of its own.
  • 4 other devices also cite its predicate K984053.

How does its category compare?

All GWM devices

GWM Device, Monitoring, Intracranial Pressure: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.

FDA decisions per year · GWM

1in 2025

2007: 22008: 22009: 12010: 22011: 32012: 42013: 22014: 22016: 32017: 32018: 12019: 22020: 32021: 22024: 22025: 12026 (partial year): 1
2007high 4 (2012) · low 0 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GWM

30in 2020

2011: 123 days median2012: 100 days median2016: 192 days median2017: 37 days median2020: 30 days median
2007high 192 (2016) · low 30 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GWM

3in 2025

2008: 12010: 92011: 62012: 12013: 122014: 22019: 12023: 1, 1 Class I2024: 4, 2 Class I2025: 3
2007high 12 (2013) · low 0 (2007)2026

Class I (3 since 2007) Class II/III not classified

Adverse event reports per year · GWM

441in 2025

2007: 1262008: 1052009: 1172010: 1042011: 1842012: 1512013: 1202014: 3602015: 4862016: 4192017: 4452018: 3022019: 2602020: 2682021: 2112022: 4242023: 7442024: 6412025: 441
2007high 744 (2023) · low 104 (2010)2025

MAUDE reports naming product code GWM, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—0126
20082—1105
20091—0117
20102—9104
201131236184
201241001151
20132—12120
20142—2360
20150—0486
201631920419
20173370445
20181—0302
20192—1260
20203300268
20212—0211
20220—0424
20230—1 (1)744
20242—4 (2)641
20251—3441
20261—0—

What is it indicated for?

Draining and monitoring of CSF flow from the lateral ventricles or lumbar subarachnoid space is indicated in selected patients to: 1. Reduce intracranial pressure (ICP), e.g., pre-, intra- or postoperative; 2. Monitor CSF chemistry, cytology, and physiology; 3. Provide temporary CSF drainage in patients with infected cerebrospinal fluid shunts. Monitoring of intracranial pressure (ICP) is indicated in selected patients with: 1. Severe head injury 2.…

Read the full statement (112 words)

Draining and monitoring of CSF flow from the lateral ventricles or lumbar subarachnoid space is indicated in selected patients to:

1. Reduce intracranial pressure (ICP), e.g., pre-, intra- or postoperative;

2. Monitor CSF chemistry, cytology, and physiology;

3. Provide temporary CSF drainage in patients with infected cerebrospinal fluid shunts.

Monitoring of intracranial pressure (ICP) is indicated in selected patients with:

1. Severe head injury

2. Subarachnoid hemorrhage graded III, IV, or V preoperatively

3. Reyes syndrome or similar encephalopathies

4. Hydrocephalus

5. Intracranial hemorrhage

6. Miscellaneous problems when drainage is to be used as a therapeutic maneuver.

Monitoring can also be used to evaluate the status pre- and postoperatively for space-occupying lesions.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K200456: Becker External Drainage and Monitoring System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K200456

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026