510(k) Report

510(k) · Cleared

Cleared

Intraoral Sensor

K201247510(k) TraditionalCleared Jun 10, 202030-day reviewClass II21 CFR 892.1680

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Dentium Co., Ltd (Ict Branch) · MQB Solid State X-Ray Imager (Flat Panel/Digital Imager)

Cleared on Jun 10, 2020 as substantially equivalent to K143000 (Ray Co., Ltd., 2015) after a 30-day review. Its family tree reaches back 7 generations to 1994.

Decided
Jun 10, 2020
Review
30 days
Class
Class II
Product code
MQB
Recalls
None
Predicates
1

Its longest line of descent runs back 7 generations to K933455 (1994). 8 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 7 generations backK933455 Computed Oral Radiology SystemSchick Technologies, Inc. · 1994
  2. 6 generations backK022953 Modification to Computed Oral Radiology SystemSchick Technologies, Inc. · 2002
  3. 5 generations backK072134 Schick Computed Oral Radiology SystemSchick Technologies, Inc. · 2007
  4. 4 generations backK090526 Medical Image Processing Unit, Model EzsensorE-Woo Technology · 2009
  5. 3 generations backK113360 Medical Image Processing UnitHumanray Co,Ltd · 2012
  6. 2 generations backK121132 Ezsensor P Digital Intraoral SensorHumanray Co,Ltd · 2012
  7. 1 generation backK143000 RIS500Ray Co., Ltd. · 2015
  8. This deviceK201247 Intraoral SensorDentium Co., Ltd (Ict Branch) · 2020
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K933455Computed Oral Radiology SystemSchick Technologies, Inc.1994—
−6K022953Modification to Computed Oral Radiology SystemSchick Technologies, Inc.2002—
−5K072134Schick Computed Oral Radiology SystemSchick Technologies, Inc.2007—
−4K090526Medical Image Processing Unit, Model EzsensorE-Woo Technology2009—
−3K113360Medical Image Processing UnitHumanray Co,Ltd2012—
−2K121132Ezsensor P Digital Intraoral SensorHumanray Co,Ltd2012—
−1K143000RIS500Ray Co., Ltd.2015—
0 (this device)K201247Intraoral SensorDentium Co., Ltd (Ict Branch)2020—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200410
FIG. 1 — Lineage of K201247, 1994–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MQB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MQB device

  1. #1 K201528 Yushan X-Ray Flat Panel Detector with DROCscore 21.5 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K143000RIS500
Summary page 4
…R 892.1680 Regulatory Class: II Product code: MQB, MUH Panel: Radiology Predicate device Predicate device (K143000) Trade/Device Name: RIO Sensor (RIS 500) Regulation Number: 21 CFR 892.1680 Regulation Name:…
Ray Co., Ltd.2015—
†K090526Medical Image Processing Unit, Model EzsensorE-Woo Technology2009—

Also cleared against K143000: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 26 years and passes through 5 companies; a new generation was cleared every 2.7 years on median.
  • None of the 8 ancestors has a recall.
  • 1 other device also cites its predicate K143000.

How does its category compare?

All MQB devices

MQB Solid State X-Ray Imager (Flat Panel/Digital Imager): FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.

FDA decisions per year · MQB

8in 2025

2007: 132008: 82009: 152010: 112011: 242012: 222013: 212014: 322015: 212016: 222017: 312018: 162019: 222020: 192021: 212022: 312023: 102024: 82025: 82026 (partial year): 3
2007high 32 (2014) · low 8 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MQB

127in 2025

2007: 22 days median2008: 15 days median2009: 57 days median2010: 116 days median2011: 102 days median2012: 80 days median2013: 105 days median2014: 102 days median2015: 81 days median2016: 92 days median2017: 30 days median2018: 30 days median2019: 30 days median2020: 28 days median2021: 48 days median2022: 48 days median2023: 30 days median2024: 187 days median2025: 127 days median2026 (partial year): 245 days median
2007high 245 (2026) · low 15 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MQB

1in 2025

2007: 152008: 362009: 192010: 142011: 102012: 82013: 62017: 12018: 42019: 12020: 42021: 12025: 12026 (partial year): 1
2007high 36 (2008) · low 0 (2014)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MQB

141in 2025

2007: 252008: 302009: 342010: 392011: 1012012: 2672013: 1592014: 292015: 212016: 262017: 202018: 842019: 452020: 92021: 262022: 132023: 512024: 912025: 141
2007high 267 (2012) · low 9 (2020)2025

MAUDE reports naming product code MQB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200713221525
20088153630
200915571934
2010111161439
20112410210101
201222808267
2013211056159
201432102029
20152181021
20162292026
20173130120
20181630484
20192230145
2020192849
20212148126
20223148013
20231030051
20248187091
202581271141
202632451—

What is it indicated for?

Intra Oral Sensor (model: IOX 1 / IOX 2) is intended to collect dental x-ray photons and convert them into electronic impulses that may be stored, views and manipulated for diagnostic use by dentists.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K201247: Intraoral Sensor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K201247

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026