510(k) Report

510(k) · Cleared

Cleared

bright CT

K231181510(k) SpecialCleared Dec 14, 2023232-day reviewClass II21 CFR 892.1750

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Dentium Co., Ltd (Ict Branch) · OAS X-Ray, Tomography, Computed, Dental

Cleared on Dec 14, 2023 as substantially equivalent to K200271 (Dentium Co., Ltd (Ict Branch), 2021) after a 232-day review. Its family tree reaches back 2 generations to 2020.

Decided
Dec 14, 2023
Review
232 days
Class
Class II
Product code
OAS
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K193139 (2020). No later device cites it as a predicate yet.

  1. Root · 2 generations backK193139 ProVecta 3D Prime CephDurr Dental SE · 2020
  2. 1 generation backK200271 rainbow CTDentium Co., Ltd (Ict Branch) · 2021
  3. This deviceK231181 bright CTDentium Co., Ltd (Ict Branch) · 2023
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K193139ProVecta 3D Prime CephDurr Dental SE2020—
−1K200271rainbow CTDentium Co., Ltd (Ict Branch)2021—
0 (this device)K231181bright CTDentium Co., Ltd (Ict Branch)2023—
FIG. 1 — Lineage of K231181, 2020–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OAS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OAS device

  1. #1 K213226 RCT700score 18.0 · 13 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K200271rainbow CT
Summary page 4
…1750 Device Class 2 4. Predicate Device: Legally Marketed Predicate Device Information: 510(k) Number: K200271 Trade /Proprietary Name: rainbow CT Device Classification Name: X-Ray, Tomography, Computed, D…
Dentium Co., Ltd (Ict Branch)2021—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 3 years and passes through 2 companies; a new generation was cleared every 2.7 years on median.
  • None of the 2 ancestors has a recall.

How does its category compare?

All OAS devices

OAS X-Ray, Tomography, Computed, Dental: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · OAS

9in 2025

2007: 22008: 22009: 22010: 12011: 62012: 72013: 102014: 52015: 52016: 122017: 42018: 112019: 72020: 92021: 112022: 62023: 122024: 42025: 92026 (partial year): 9
2007high 12 (2016) · low 1 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OAS

144in 2025

2011: 168 days median2012: 110 days median2013: 155 days median2014: 170 days median2015: 164 days median2016: 154 days median2017: 209 days median2018: 57 days median2019: 55 days median2020: 113 days median2021: 92 days median2022: 105 days median2023: 77 days median2024: 129 days median2025: 144 days median2026 (partial year): 77 days median
2007high 209 (2017) · low 55 (2019)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OAS

3in 2025

2015: 12025: 3
2007high 3 (2025) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · OAS

1in 2025

2008: 12019: 12022: 12023: 12024: 22025: 1
2007high 2 (2024) · low 0 (2007)2025

MAUDE reports naming product code OAS, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—00
20082—01
20092—00
20101—00
2011616800
2012711000
20131015500
2014517000
2015516410
20161215400
2017420900
2018115700
201975501
2020911300
2021119200
2022610501
2023127701
2024412902
2025914431
20269770—

What is it indicated for?

bright CT is a computed tomography x-ray system intended to produce 3D, panoramic, and cephalometric diagnostic images of the maxillofacial areas for treatment planning for adult and pediatric patients. The device is operated and used by physicians, dentists, and x-ray technicians.

Rainbow 3D Image Viewer software features functions for acquiring, saving, searching, displaying, diagnosing and sending digital X-ray image data in dental practices and clinics.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K231181: bright CT.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K231181

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026