510(k) Report

510(k) · Cleared

Cleared

Vitrea Software Package, VSTP-001A

K203312510(k) TraditionalCleared Feb 16, 202198-day reviewClass II21 CFR 892.2050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Canon Medical Systems Corporation · LLZ System, Image Processing, Radiological

Cleared on Feb 16, 2021 as substantially equivalent to K192923 (Canon Medical Systems Corporation, 2020) after a 98-day review. Its family tree reaches back 16 generations to 1991. 7 later devices descend from it.

Decided
Feb 16, 2021
Review
98 days
Class
Class II
Product code
LLZ
Recalls
None
Predicates
1

Its longest line of descent runs back 16 generations to K913770 (1991). 179 ancestors in all, the oldest K871859 (1987). 7 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2018: 1 other ancestor2015: 3 other ancestors2012: 4 other ancestors2010: 2 other ancestors2008: 2 other ancestors2006: 8 other ancestors2014: 1 other ancestor2013: 1 other ancestor2011: 2 other ancestors2009: 2 other ancestors2007: 4 other ancestors2005: 9 other ancestors2004: 13 other ancestors2001: 17 other ancestors2003: 15 other ancestors2002: 17 other ancestors2000: 12 other ancestors1999: 5 other ancestors1998: 8 other ancestors1997: 6 other ancestors1995: 7 other ancestors1994: 4 other ancestors1993: 4 other ancestors1996: 6 other ancestors1992: 2 other ancestors1989: 2 other ancestors1987: 1 other ancestor1991: 4 other ancestors1990: 1 other ancestor2022: 1 descendant cleared2023: 1 descendant cleared2024: 3 descendants cleared2025: 1 descendant cleared2026: 1 descendant clearedK913770 · Advantage V.S. CT/MR Rad Diagnostic Workstation · General Electric Co. · 1991K960613 · GE Advantage Windows Review Workstation · GE Medical Systems · 1996K020483 · Advantage Workstation 4.1 · GE Medical Systems · 2002 · recalledK023003 · Imagechecker-CT Workstation · R2 Technology, Inc. · 2002×2: 2 generations cleared close together, K032748 (2003), K040305 (2004) K043333 · VITREA2, Version 3.7 Medical Image Processing System · Vital Images, Inc. · 2004 · recalledK052632 · VITREA2 Version 3.8 Medical Image Processing Software · Vital Images, Inc. · 2005 · recalledK061624 · Vitrea, Version 3.9 · Vital Images, Inc. · 2006 · recalledK071331 · Vitrea Version 4.0 · Vital Images, Inc. · 2007 · recalledK073156 · Qplaque MR · Medis Medical Imaging Systems BV · 2008K120636 · Synapse 3D Cardiac Tools · Fujifilm Medical System U.S.A., Inc. · 2012K171222 · Vitrea Software Toshiba Package; VSTP-001A · Toshibamedical Systems Corporation · 2017K173088 · Vitrea Software Toshiba Package VSTP-001A · Toshibamedical Systems Corporation · 2018K183013 · Vitrea Software Package, VSTP-001A · Canon Medical Systems Corporation · 2018K192923 · Vitrea Software Package · Canon Medical Systems Corporation · 20201990200020102020
Other ancestors, by generationDescendants, by generation 3 generations back: 2 other ancestors4 generations back: 6 other ancestors5 generations back: 15 other ancestors6 generations back: 33 other ancestors7 generations back: 40 other ancestors8 generations back: 31 other ancestors9 generations back: 16 other ancestors10 generations back: 15 other ancestors11 generations back: 3 other ancestors12 generations back: 2 other ancestors 1 generation forward: 1 descendant2 generations forward: 2 descendants3 generations forward: 2 descendants4 generations forward: 2 descendants K192923 · Vitrea Software Package · Canon Medical Systems Corporation · 2020K183013 · Vitrea Software Package, VSTP-001A · Canon Medical Systems Corporation · 2018K173088 · Vitrea Software Toshiba Package VSTP-001A · Toshibamedical Systems Corporation · 2018K171222 · Vitrea Software Toshiba Package; VSTP-001A · Toshibamedical Systems Corporation · 2017K120636 · Synapse 3D Cardiac Tools · Fujifilm Medical System U.S.A., Inc. · 2012K073156 · Qplaque MR · Medis Medical Imaging Systems BV · 2008K071331 · Vitrea Version 4.0 · Vital Images, Inc. · 2007 · recalledK061624 · Vitrea, Version 3.9 · Vital Images, Inc. · 2006 · recalledK052632 · VITREA2 Version 3.8 Medical Image Processing Software · Vital Images, Inc. · 2005 · recalledK043333 · VITREA2, Version 3.7 Medical Image Processing System · Vital Images, Inc. · 2004 · recalledK040305 · VITREA2 Version 3.5 · Vital Images, Inc. · 2004K032748 · VITREA2, Version 3.4 Medical Image Processing Software · Vital Images, Inc. · 2003 · recalledK023003 · Imagechecker-CT Workstation · R2 Technology, Inc. · 2002K020483 · Advantage Workstation 4.1 · GE Medical Systems · 2002 · recalledK960613 · GE Advantage Windows Review Workstation · GE Medical Systems · 1996K913770 · Advantage V.S. CT/MR Rad Diagnostic Workstation · General Electric Co. · 1991−15−10−50
  1. Root · 16 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. 12 generations between
  3. 3 generations backK173088 Vitrea Software Toshiba Package VSTP-001AToshibamedical Systems Corporation · 2018
  4. 2 generations backK183013 Vitrea Software Package, VSTP-001ACanon Medical Systems Corporation · 2018
  5. 1 generation backK192923 Vitrea Software PackageCanon Medical Systems Corporation · 2020
  6. This deviceK203312 Vitrea Software Package, VSTP-001ACanon Medical Systems Corporation · 2021
  7. Descendant · cites it directly · 6 of its ownK213504 Aquilion ONE (TSX-306A/3) V10.12 with Spectral Imaging System…Canon Medical Systems Corporation · 2022
  8. Descendant · 2 generations on · 3 of its ownK232835 Aquilion ONE (TSX-308A/3) V1.4 with PIQE Reconstruction SystemCanon Medical Systems Corporation · 2024
  9. Descendant · 3 generations on · 2 of its ownK242403 Aquilion ONE (TSX-308A/3) V1.5Canon Medical Systems Corporation · 2024
  10. Descendant · 2 generations on · 1 of its ownK223336 Vitrea Software Package, VSTP-002ACanon Medical Systems Corporation · 2023
  11. Descendant · 4 generations on · 0 of its ownK253596 Aquilion ONE (TSX-308A/TSX-306A) V2.0Canon Medical Systems Corporation · 2026
Show all 16 generations
  1. Root · 16 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. 15 generations backK960613 GE Advantage Windows Review WorkstationGE Medical Systems · 1996
  3. 14 generations backK020483 Advantage Workstation 4.1GE Medical Systems · 2002 · Recalled
  4. 13 generations backK023003 Imagechecker-CT WorkstationR2 Technology, Inc. · 2002
  5. 12 generations backK032748 VITREA2, Version 3.4 Medical Image Processing SoftwareVital Images, Inc. · 2003 · Recalled
  6. 11 generations backK040305 VITREA2 Version 3.5Vital Images, Inc. · 2004
  7. 10 generations backK043333 VITREA2, Version 3.7 Medical Image Processing SystemVital Images, Inc. · 2004 · Recalled
  8. 9 generations backK052632 VITREA2 Version 3.8 Medical Image Processing SoftwareVital Images, Inc. · 2005 · Recalled
  9. 8 generations backK061624 Vitrea, Version 3.9Vital Images, Inc. · 2006 · Recalled
  10. 7 generations backK071331 Vitrea Version 4.0Vital Images, Inc. · 2007 · Recalled
  11. 6 generations backK073156 Qplaque MRMedis Medical Imaging Systems BV · 2008
  12. 5 generations backK120636 Synapse 3D Cardiac ToolsFujifilm Medical System U.S.A., Inc. · 2012
  13. 4 generations backK171222 Vitrea Software Toshiba Package; VSTP-001AToshibamedical Systems Corporation · 2017
  14. 3 generations backK173088 Vitrea Software Toshiba Package VSTP-001AToshibamedical Systems Corporation · 2018
  15. 2 generations backK183013 Vitrea Software Package, VSTP-001ACanon Medical Systems Corporation · 2018
  16. 1 generation backK192923 Vitrea Software PackageCanon Medical Systems Corporation · 2020
  17. This deviceK203312 Vitrea Software Package, VSTP-001ACanon Medical Systems Corporation · 2021

Showing 5 of 7 descendants. See all descendants

Descendants cleared per year

2022: 12023: 12024: 32025: 12026: 1
2022high 3 (2024) · low 1 (2022)2026

Most influential descendants

Showing 5 of 7 · See all
  • K213504Aquilion ONE (TSX-306A/3) V10.12 with Spectral Imaging System, Vitrea Software Package…Canon Medical Systems Corporation · 2022 · cites it directly6descendants
  • K232835Aquilion ONE (TSX-308A/3) V1.4 with PIQE Reconstruction SystemCanon Medical Systems Corporation · 2024 · 2 generations on3descendants
  • K242403Aquilion ONE (TSX-308A/3) V1.5Canon Medical Systems Corporation · 2024 · 3 generations on2descendants
  • K223336Vitrea Software Package, VSTP-002ACanon Medical Systems Corporation · 2023 · 2 generations on1descendant
  • K253596Aquilion ONE (TSX-308A/TSX-306A) V2.0Canon Medical Systems Corporation · 2026 · 4 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−16K913770Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co.1991—
−15K960613GE Advantage Windows Review WorkstationGE Medical Systems1996—
−14K020483Advantage Workstation 4.1GE Medical Systems20022
−13K023003Imagechecker-CT WorkstationR2 Technology, Inc.2002—
−12K032748VITREA2, Version 3.4 Medical Image Processing SoftwareVital Images, Inc.20032
−11K040305VITREA2 Version 3.5Vital Images, Inc.2004—
−10K043333VITREA2, Version 3.7 Medical Image Processing SystemVital Images, Inc.20041
−9K052632VITREA2 Version 3.8 Medical Image Processing SoftwareVital Images, Inc.20052
−8K061624Vitrea, Version 3.9Vital Images, Inc.20061
−7K071331Vitrea Version 4.0Vital Images, Inc.20071
−6K073156Qplaque MRMedis Medical Imaging Systems BV2008—
−5K120636Synapse 3D Cardiac ToolsFujifilm Medical System U.S.A., Inc.2012—
−4K171222Vitrea Software Toshiba Package; VSTP-001AToshibamedical Systems Corporation2017—
−3K173088Vitrea Software Toshiba Package VSTP-001AToshibamedical Systems Corporation2018—
−2K183013Vitrea Software Package, VSTP-001ACanon Medical Systems Corporation2018—
−1K192923Vitrea Software PackageCanon Medical Systems Corporation2020—
0 (this device)K203312Vitrea Software Package, VSTP-001ACanon Medical Systems Corporation2021—
+1K213504Aquilion ONE (TSX-306A/3) V10.12 with Spectral Imaging System, Vitrea Software…Canon Medical Systems Corporation2022—
+2K232835Aquilion ONE (TSX-308A/3) V1.4 with PIQE Reconstruction SystemCanon Medical Systems Corporation2024—
+3K242403Aquilion ONE (TSX-308A/3) V1.5Canon Medical Systems Corporation2024—
+2K223336Vitrea Software Package, VSTP-002ACanon Medical Systems Corporation2023—
+4K253596Aquilion ONE (TSX-308A/TSX-306A) V2.0Canon Medical Systems Corporation2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198710
198920
199010
199140
199220
199340
199440
199570
199660
199760
199880
199950
2000120
2001170
2002170
2003150
2004130
200590
200680
200740
200820
200920
201020
201120
201240
201310
201410
201530
201810

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202210
202310
202430
202510
202610
FIG. 1 — Lineage of K203312, 1991–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LLZ device

  1. #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K192923Vitrea Software Package
Summary page 5
…Medical 21 CFR and LLZ K192923 10/15/2019 VSTP-001A* Systems, 892.2050 Communications…
Canon Medical Systems Corporation2020—

What descends from it? (7)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K213504Aquilion ONE (TSX-306A/3) V10.12 with Spectral Imaging System, Vitrea Software Package…Canon Medical Systems Corporation20226

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 30 years and passes through 8 companies; a new generation was cleared every 11 months on median.
  • 57 of the 179 ancestors have a recall of any class.
  • Of its descendants, K213504 (Canon Medical Systems Corporation, 2022) has gone furthest, with 6 descendants of its own.

How does its category compare?

All LLZ devices

LLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · LLZ

58in 2025

2007: 762008: 942009: 702010: 512011: 1062012: 822013: 952014: 782015: 642016: 822017: 782018: 1042019: 742020: 812021: 832022: 652023: 872024: 622025: 582026 (partial year): 45
2007high 106 (2011) · low 51 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LLZ

173in 2025

2007: 36 days median2008: 52 days median2009: 62 days median2010: 98 days median2011: 79 days median2012: 87 days median2013: 84 days median2014: 89 days median2015: 90 days median2016: 90 days median2017: 107 days median2018: 105 days median2019: 107 days median2020: 115 days median2021: 116 days median2022: 137 days median2023: 157 days median2024: 131 days median2025: 173 days median2026 (partial year): 110 days median
2007high 173 (2025) · low 36 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LLZ

11in 2025

2007: 202008: 322009: 212010: 172011: 302012: 122013: 642014: 62015: 162016: 122017: 52018: 72019: 22020: 62021: 32022: 42023: 82024: 62025: 112026 (partial year): 14
2007high 64 (2013) · low 2 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LLZ

116in 2025

2007: 1522008: 1542009: 1452010: 1452011: 4542012: 2662013: 1,1302014: 15,6312015: 2112016: 2902017: 1042018: 722019: 882020: 822021: 702022: 282023: 262024: 422025: 116
2007high 15,631 (2014) · low 26 (2023)2025

MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007763620152
2008945232154
2009706221145
2010519817145
20111067930454
2012828712266
20139584641,130
20147889615,631
2015649016211
2016829012290
2017781075104
2018104105772
201974107288
202081115682
202183116370
202265137428
202387157826
202462131642
20255817311116
20264511014—

What is it indicated for?

Vitrea Software Package is an application package developed for use on Vitrea®, a medical diagnostic system that allows the processing, review, analysis, communication and media interchange of multi-dimensional digital images acquired from a variety of imaging devices. Vitrea has the following additional indications: The Cerebral Aneurysm Analysis application is intended to facilitate the extraction and segmentation of user identified aneurysms on the…

Read the full statement (498 words)

Vitrea Software Package is an application package developed for use on Vitrea®, a medical diagnostic system that allows the processing, review, analysis, communication and media interchange of multi-dimensional digital images acquired from a variety of imaging devices. Vitrea has the following additional indications:

The Cerebral Aneurysm Analysis application is intended to facilitate the extraction and segmentation of user identified aneurysms on the cerebral arteries. The software can be used as an adjunct to diagnosis for the purposes of measurement of size and aspect ratio.

The MR Wall Motion Tracking application is intended to assist physicians with performing cardiac functional analysis based upon magnetic resonance images. It provides measurements of global and regional myocardial function that is used for patients with suspected heart disease.

The MR Coronary Tracking application is intended to assist physicians with performing coronary artery analysis for MR heart images which are intended for the qualitative and quantitative analysis of coronary arteries.

The SUREVolume Synthesis application is intended to load volume images acquired by whole-body X-ray CT scanners, X-ray angiography systems, and MRI systems and displays fusion images.

The Angio Viewer application displays image data acquired using an X-ray angiography system. It supports cine display, subtraction, and distance measurement.

The US Cardiac Fusion application enables fusion display of the analysis results obtained using the US 3D Wall Motion Tracking application and the CT Coronary Artery Analysis application.

The Ultrasound Clinical Applications are indicated for the visualization of structures, and dynamic processes with the human body using saved ultrasound DICOM images to provide image information for diagnosis.

The Spectral Stone Analysis application is intended to serve as an adjunct visualization tool for the differentiation between uric acid and non-uric acid stones greater than 3 mm with Spectral CT studies acquired on the Canon Medical Systems scanner.

The Spectral Composition Analysis application is intended to assist a physician in visualizing the presence of monosodium urate in anatomical structures. The clinical syndrome of gout is characterized by the presence of monosodium urate crystals in joints or soft tissue.

The Embolization Plan application is a post processing software that is intended to assist physicians in the visualization of the liver arterial tree using 3D images of CT or 3D images of Cone Beam CT acquired by Toshiba or Canon Medical Systems. It provides tools to assist the user in analysis of these images. The output is intended to be an adjunct means that allows automatic and manual planning of the liver arterial vessels for guidance of the embolization procedure. The output is a 3D visualization of the hepatic arteries to high dense lesion in the liver.

The Spectral Analysis application is a CT, non-invasive image analysis software package, which may be used to aid in the visualization of anatomical and pathological materials. The software provides quantification of Hounsfield units of iodine attenuation differences and iodine concentration and display by color.

Effective Z and Electron Density maps may aid in the differentiation and characterization of different tissues in the human body.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K203312: Vitrea Software Package, VSTP-001A.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K203312

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026