510(k) Report

510(k) · Cleared

Cleared

CPM Medical Consultants Tibial Revision Knee System

K210695510(k) TraditionalCleared Aug 16, 2021161-day reviewClass II21 CFR 888.3560

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Cpm Medical Consultants, LLC · JWH Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

Cleared on Aug 16, 2021 as substantially equivalent to K142649 (The Progressive Orthopaedic Company, LLC, 2015) and 3 other predicates after a 161-day review. Its family tree reaches back 5 generations to 1992.

Decided
Aug 16, 2021
Review
161 days
Class
Class II
Product code
JWH
Recalls
None
Predicates
4

Its longest line of descent runs back 5 generations to K915132 (1992). 15 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2015: 2 other ancestors2008: 1 other ancestor2013: 2 other ancestors2006: 1 other ancestor1996: 1 other ancestor2002: 1 other ancestor2001: 1 other ancestor1995: 1 other ancestorK915132 · MCK Maximum Congruent Knee) Knee System · Biomet, Inc. · 1992 · recalledK023546 · Maxim Accel Knee System · Biomet, Inc. · 2003 · recalledK042757 · Vanguard SSK Knee System · Biomet, Inc. · 2005 · recalledK093293 · Vanguard 360 Revision Knee System · Biomet, Inc. · 2010 · recalledK122183 · Augment and Screw, Psa Type · United Orthopedic Corp. · 20131990199520002005201020152020
  1. Root · 5 generations backK915132 MCK Maximum Congruent Knee) Knee SystemBiomet, Inc. · 1992 · Recalled
  2. 4 generations backK023546 Maxim Accel Knee SystemBiomet, Inc. · 2003 · Recalled
  3. 3 generations backK042757 Vanguard SSK Knee SystemBiomet, Inc. · 2005 · Recalled
  4. 2 generations backK093293 Vanguard 360 Revision Knee SystemBiomet, Inc. · 2010 · Recalled
  5. 1 generation backK122183 Augment and Screw, Psa TypeUnited Orthopedic Corp. · 2013
  6. This deviceK210695 CPM Medical Consultants Tibial Revision Knee SystemCpm Medical Consultants, LLC · 2021
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K915132MCK Maximum Congruent Knee) Knee SystemBiomet, Inc.19926
−4K023546Maxim Accel Knee SystemBiomet, Inc.200313
−3K042757Vanguard SSK Knee SystemBiomet, Inc.20051
−2K093293Vanguard 360 Revision Knee SystemBiomet, Inc.20105
−1K122183Augment and Screw, Psa TypeUnited Orthopedic Corp.2013—
0 (this device)K210695CPM Medical Consultants Tibial Revision Knee SystemCpm Medical Consultants, LLC2021—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199510
199610
200110
200210
200610
200810
201320
201520
FIG. 1 — Lineage of K210695, 1992–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JWH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JWH device

  1. #1 K221479 Persona Personalized Knee Systemscore 22.4 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K142649Progressive Orthopedic Total Knee System
Summary page 3
…ed use only. The CPM Medical Consultants Tibial Revision Knee System is to be used in conjunction with the Progressive Orthopaedic Company Total Knee System cleared via K142649 & K150783. See below for a compatibility chart between systems. Type of Use (Select one or both, as applicable)…
The Progressive Orthopaedic Company, LLC2015—
*K150783Progressive Orthopaedic Total Knee System
Summary page 3
…y. The CPM Medical Consultants Tibial Revision Knee System is to be used in conjunction with the Progressive Orthopaedic Company Total Knee System cleared via K142649 & K150783. See below for a compatibility chart between systems. Type of Use (Select one or both, as applicable) Presc…
The Progressive Orthopaedic Company, LLC2015—
*K082424United U2 Total Knee System
Summary page 4
…cleared as the Progressive Orthopaedic Company Total Knee System (K142649/K150783), and the United Orthopedic Corporation U2 Total Knee System as the predicate devices (K082424/K122183). The CPM Medical Consultants Tibial Revision Knee System features component designs, materials, indications, and manufac…
United Orthopedic Corp.20082
*K122183Augment and Screw, Psa Type
Summary page 4
…as the Progressive Orthopaedic Company Total Knee System (K142649/K150783), and the United Orthopedic Corporation U2 Total Knee System as the predicate devices (K082424/K122183). The CPM Medical Consultants Tibial Revision Knee System features component designs, materials, indications, and manufacturing m…
United Orthopedic Corp.2013—

Also cleared against K142649: 7 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 29 years and passes through 3 companies; a new generation was cleared every 5.7 years on median.
  • 8 of the 15 ancestors have a recall of any class.
  • 7 other devices also cite its predicate K142649.

How does its category compare?

All JWH devices

JWH Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · JWH

20in 2025

2007: 182008: 172009: 112010: 192011: 252012: 332013: 312014: 332015: 272016: 182017: 252018: 252019: 282020: 222021: 242022: 172023: 202024: 192025: 202026 (partial year): 12
2007high 33 (2012) · low 11 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JWH

55in 2025

2007: 74 days median2008: 81 days median2009: 168 days median2010: 85 days median2011: 87 days median2012: 85 days median2013: 128 days median2014: 98 days median2015: 87 days median2016: 88 days median2017: 118 days median2018: 90 days median2019: 133 days median2020: 59 days median2021: 61 days median2022: 56 days median2023: 57 days median2024: 89 days median2025: 55 days median2026 (partial year): 63 days median
2007high 168 (2009) · low 55 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JWH

2in 2025

2007: 142008: 102009: 1092010: 322011: 272012: 852013: 312014: 132015: 112016: 172017: 612018: 142019: 52020: 22021: 82022: 122023: 672024: 72025: 22026 (partial year): 4
2007high 109 (2009) · low 2 (2020)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JWH

9,306in 2025

2007: 1,3052008: 1,4832009: 1,8702010: 3,2862011: 5,1332012: 5,2032013: 6,1352014: 6,7222015: 6,8812016: 7,5862017: 12,2632018: 14,0712019: 14,9872020: 12,5922021: 9,4082022: 8,3642023: 8,9472024: 10,8282025: 9,306
2007high 14,987 (2019) · low 1,305 (2007)2025

MAUDE reports naming product code JWH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071874141,305
20081781101,483
2009111681091,870
20101985323,286
20112587275,133
20123385855,203
201331128316,135
20143398136,722
20152787116,881
20161888177,586
2017251186112,263
201825901414,071
201928133514,987
20202259212,592
2021246189,408
20221756128,364
20232057678,947
20241989710,828
2025205529,306
202612634—

What is it indicated for?

The CPM Medical Consultants Tibial Revision Knee System is indicated in knee arthroplasty for reduction or relief of pain and/or improved knee function in skeletally mature patients with severe knee pain and disability due to rheumatoid arthritis, osteoarthritis, primary and secondary traumatic arthritis, polyarthritis, collagen disorders, avascular necrosis of the femoral condyle or pseudogout, posttraumatic loss of joint configuration, particularly…

Read the full statement (206 words)

The CPM Medical Consultants Tibial Revision Knee System is indicated in knee arthroplasty for reduction or relief of pain and/or improved knee function in skeletally mature patients with severe knee pain and disability due to rheumatoid arthritis, osteoarthritis, primary and secondary traumatic arthritis, polyarthritis, collagen disorders, avascular necrosis of the femoral condyle or pseudogout, posttraumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy, moderate valgus, varus, or flexion deformities. The device is intended for use in patients who require augmentation and/or stem extensions due to inadequate bone stock and/or require constrained stabilization for tibiofemoral joint due to soft tissue in-balance. The tibial augments are to be attached to their respective components with a fixation screw or screws.

The CPM Medical Consultants Tibial Revision Knee System may also be indicated in the salvage of previously failed surgical attempts if the knee can be satisfactorily balanced and stabilized at the time of surgery. The CPM Medical Consultants Tibial Revision Knee System is designed for cemented use only.

The CPM Medical Consultants Tibial Revision Knee System is to be used in conjunction with the Progressive Orthopaedic Company Total Knee System cleared via K142649 & K150783. See below for a compatibility chart between systems.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K210695: CPM Medical Consultants Tibial Revision Knee System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K210695

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026