510(k) Report

510(k) · Cleared

Cleared

Healgen Strep A Rapid Test Strip (Throat Swab)

K212623510(k) TraditionalCleared Mar 16, 2022210-day reviewClass I21 CFR 866.3740

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Healgen Scientific,, LLC · GTY Antigens, All Groups, Streptococcus Spp.

Cleared on Mar 16, 2022 as substantially equivalent to K133343 (Guangzhou Wondfo Biotech Co., Ltd., 2014) after a 210-day review. Its family tree reaches back 3 generations to 1997.

Decided
Mar 16, 2022
Review
210 days
Class
Class I
Product code
GTY
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K971349 (1997). No later device cites it as a predicate yet.

  1. Root · 3 generations backK971349 Biosign Strep a - Direct Strep a Antigen TestPrinceton BioMeditech Corp. · 1997
  2. 2 generations backK040708 Status First Strep aPrinceton BioMeditech Corp. · 2004
  3. 1 generation backK133343 Wondfo Rapid Strep a TestGuangzhou Wondfo Biotech Co., Ltd. · 2014
  4. This deviceK212623 Healgen Strep A Rapid Test Strip (Throat Swab)Healgen Scientific,, LLC · 2022
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K971349Biosign Strep a - Direct Strep a Antigen TestPrinceton BioMeditech Corp.1997—
−2K040708Status First Strep aPrinceton BioMeditech Corp.2004—
−1K133343Wondfo Rapid Strep a TestGuangzhou Wondfo Biotech Co., Ltd.2014—
0 (this device)K212623Healgen Strep A Rapid Test Strip (Throat Swab)Healgen Scientific,, LLC2022—
FIG. 1 — Lineage of K212623, 1997–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GTY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GTY device

  1. #1 K260342 AllTest Strep A Rapid Testscore 11.9 · 3 generations · no Class I recall
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K133343Wondfo Rapid Strep a Test
Summary page 4
…R # Panel GTY 866.3740 streptococcus spp serological reagents Microbiology 5. Predicate Devices: K133343 Wondfo Strep A Rapid Test Guangzhou Wondfo Biotech Co., Ltd. 6. Intended Use/Indications for Use The Strep A Rapid Tes…
Guangzhou Wondfo Biotech Co., Ltd.2014—

Also cleared against K133343: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 25 years and passes through 3 companies; a new generation was cleared every 8.1 years on median.
  • None of the 3 ancestors has a recall.
  • 1 other device also cites its predicate K133343.

How does its category compare?

All GTY devices

GTY Antigens, All Groups, Streptococcus Spp.: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.

FDA decisions per year · GTY

1in 2025

2008: 12009: 12013: 22014: 22017: 12022: 12025: 12026 (partial year): 1
2007high 2 (2013) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GTY

Too few GTY 510(k)s in any year since 2007 to give a median.

Recalls per year · GTY

4in 2011

2011: 42026 (partial year): 1
2007high 4 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GTY

94in 2025

2007: 12008: 22009: 22010: 12011: 32014: 12015: 12017: 22018: 122019: 62020: 12021: 372022: 322023: 442024: 412025: 94
2007high 94 (2025) · low 0 (2012)2025

MAUDE reports naming product code GTY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—01
20081—02
20091—02
20100—01
20110—43
20120—00
20132—00
20142—01
20150—01
20160—00
20171—02
20180—012
20190—06
20200—01
20210—037
20221—032
20230—044
20240—041
20251—094
20261—1—

What is it indicated for?

The Strep A Rapid Test Strip (Throat Swab) is a rapid chromatographic immunoassay for the qualitative detection of Streptococcus pyogenes (Group A β-hemolytic Streptococcus, Strep A) antigen from throat swab specimens of symptomatic patients to aid in the diagnosis of Group A Streptococcus bacterial infection.

All negative test results should be confirmed by bacterial culture because negative results do not preclude infection with Group A Streptococcus and should not be used as the sole basis for treatment.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K212623: Healgen Strep A Rapid Test Strip (Throat Swab).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K212623

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026