510(k) · Cleared
ClearedePlex Blood Culture Identification Gram Negative (BCID-GN) Panel
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Genmark Diagnostics, Incorporated · PEN Gram-Negative Bacteria And Associated Resistance Markers
Cleared on Apr 27, 2022 as substantially equivalent to K182619 (Genmark Diagnostics, Incorporated, 2019) after a 209-day review. Its family tree reaches back 1 generation to 2019.
- Decided
- Apr 27, 2022
- Review
- 209 days
- Class
- Class II
- Product code
- PEN
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K182619 (2019). No later device cites it as a predicate yet.
- Root · 1 generation backK182619 ePlex Blood Culture Identification Gram Negative (BCID-GN) PanelGenmark Diagnostics, Incorporated · 2019
- This deviceK213236 ePlex Blood Culture Identification Gram Negative (BCID-GN) PanelGenmark Diagnostics, Incorporated · 2022
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K182619 | ePlex Blood Culture Identification Gram Negative (BCID-GN) Panel | Genmark Diagnostics, Incorporated | 2019 | — |
| 0 (this device) | K213236 | ePlex Blood Culture Identification Gram Negative (BCID-GN) Panel | Genmark Diagnostics, Incorporated | 2022 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in PEN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new PEN device
- #1 K262168 QIAstat-Dx BCID GN Plus AMR Panelscore 12.1 · 1 generation · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K182619 | ePlex Blood Culture Identification Gram Negative (BCID-GN) PanelSummary page 7…rk Diagnostics, Incorporated Predicate Device Predicate: The ePlex Blood Culture Identification Gram-Negative (BCID-GN) Panel; GenMark Diagnostics, Inc.; K182619 Device Description The ePlex Blood Culture Identification Gram-Negative (BCID-GN) Panel is based on the principles of competiti… | 2019 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Its one ancestor has no recall.
- 1 other device also cites its predicate K182619.
How does its category compare?
All PEN devicesPEN Gram-Negative Bacteria And Associated Resistance Markers: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.
FDA decisions per year · PEN
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · PEN
Too few PEN 510(k)s in any year since 2007 to give a median.
Recalls per year · PEN
1in 2023
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · PEN
13in 2025
MAUDE reports naming product code PEN, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 1 | — | 0 | 0 |
| 2014 | 1 | — | 0 | 0 |
| 2015 | 1 | — | 0 | 0 |
| 2016 | 1 | — | 0 | 0 |
| 2017 | 0 | — | 0 | 0 |
| 2018 | 1 | — | 0 | 1 |
| 2019 | 2 | — | 0 | 5 |
| 2020 | 1 | — | 1 | 4 |
| 2021 | 0 | — | 1 | 15 |
| 2022 | 1 | — | 0 | 5 |
| 2023 | 0 | — | 1 | 1 |
| 2024 | 1 | — | 0 | 8 |
| 2025 | 1 | — | 0 | 13 |
| 2026 | 1 | — | 0 | — |
What is it indicated for?
The GenMark ePlex® Blood Culture Identification Gram-Negative (BCID-GN) Panel is a qualitative nucleic acid multiplex in vitro diagnostic test intended for use on GenMark’s ePlex Instrument for simultaneous qualitative detection and identification of multiple potentially pathogenic gram-negative bacterial organisms and select determinants associated with antimicrobial resistance in positive blood culture. In addition, the ePlex BCID-GN Panel is capable…
Read the full statement (537 words)
The GenMark ePlex® Blood Culture Identification Gram-Negative (BCID-GN) Panel is a qualitative nucleic acid multiplex in vitro diagnostic test intended for use on GenMark’s ePlex Instrument for simultaneous qualitative detection and identification of multiple potentially pathogenic gram-negative bacterial organisms and select determinants associated with antimicrobial resistance in positive blood culture. In addition, the ePlex BCID-GN Panel is capable of detecting several gram-positive bacteria (Pan Gram-Positive assay) and several Candida species (Pan Candida assay). The ePlex BCID-GN Panel is performed directly on blood culture samples identified as positive by a continuous monitoring blood culture system and which contain gram-negative organism.
The following bacterial organisms and genes associated with antibiotic resistance are identified using the ePlex BCID-GN Panel: Acinetobacter baumannii, Bacteroides fragilis, Citrobacter, Cronobacter sakazakii, Enterobacter cloacae complex, Enterobacter (non-cloacae complex), Escherichia coli, Fusobacterium necrophorum, Fusobacterium nucleatum, Haemophilus influenzae, Klebsiella oxytoca, Klebsiella pneumoniae group, Morganella morganii, Neisseria meningitidis, Proteus, Proteus mirabilis, Pseudomonas aeruginosa, Salmonella, Serratia, Serratia marcescens, Stenotrophomonas maltophilia, CTX-M (blaCTX-M), IMP (blaIMP) , KPC (blaKPC) , NDM (blaNDM), OXA (blaOXA) (OXA-23 and OXA-48 groups only), and VIM (blaVIM).
The ePlex BCID-GN Panel contains assays for the detection of genetic determinants associated with resistance to antimicrobial agents including CTX-M(blaCTX-M), which is associated with resistance to extended spectrum beta-lactamase (ESBL)-mediated resistance to penicillins, cephalosporins, and monobactams, as well as OXA (blaOXA) (OXA-23 and OXA-48 groups only), KPC (blaKPC), and metallo-beta-lactamases IMP (blaIMP), VIM (blaVIM), and NDM (blaNDM), which is associated with carbapenemase-mediated resistance. The antimicrobial resistance gene detected may or may not be associated with the agent responsible for disease. Negative results for these select antimicrobial resistance assays do not indicate susceptibility, as there are multiple mechanisms of resistance in gram-negative bacteria.
The ePlex BCID-GN Panel also contains targets designed to detect a broad range of organisms with a potentially misleading Gram stain result or organisms that may be missed by Gram staining altogether, for example in the case of co-infections. These include a broad Pan Gram-Positive assay (which is designed to detect Bacillus cereus group, Bacillus subtilis group, Enterococcus, Staphylococcus, and Streptococcus), as well as a Pan Candida assay, which is designed to detect four Candida species: Candida albicans, Candida glabrata, Candida krusei, and Candida parapsilosis.
The detection and identification of specific bacterial and fungal nucleic acids from individuals exhibiting signs and/or symptoms of bloodstream infection aids in the diagnosis of bloodstream infection when used in conjunction with other clinical information. The results from the ePlex BCID-GN Panel are intended to be interpreted in conjunction with Gram stain results and should not be used as the sole basis for diagnosis, treatment, or other patient management decisions.
Negative results in the setting of a suspected bloodstream infection may be due to infection with pathogens that are not detected by this test. Positive results do not rule out co-infection with other organisms; the organism(s) detected by the ePlex BCID-GN Panel may not be the definite cause of disease. Additional laboratory testing (e.g. sub-culturing of positive blood cultures for identification of organisms not detected by ePlex BCID-GN Panel and for susceptibility testing, differentiation of mixed growth, and association of antimicrobial resistance marker genes to a specific organism) and clinical presentation must be taken into consideration in the final diagnosis of bloodstream infection.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K213236 · printed Nov 6, 2026
Cite this page
510(k) Report. “K213236: ePlex Blood Culture Identification Gram Negative (BCID-GN) Panel.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K213236