510(k) Report

510(k) · Cleared

Cleared

BD Kiestra Methicillin-resistant Staphylococcus aureus (MRSA) Application, BD Kiestra MRSA App

K213280510(k) TraditionalCleared May 4, 2023580-day reviewClass II21 CFR 866.2190

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bd Kiestra B.V. · QQY Culture Plate Imaging System For Qualitative Assessment Of Resistant Organisms

Cleared on May 4, 2023 as substantially equivalent to K200839 (Clever Culture Systems, 2021) after a 580-day review. Its family tree reaches back 3 generations to 2016.

Decided
May 4, 2023
Review
580 days
Class
Class II
Product code
QQY
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to DEN150059 (2016). No later device cites it as a predicate yet.

  1. Root · 3 generations backDEN150059 APAS Compact with Urine Analysis ModuleClever Culture Systems AG · 2016
  2. 2 generations backK183648 APAS Independence with Urine Analysis ModuleClever Culture Systems AG · 2019
  3. 1 generation backK200839 APAS Independence with IC Chromogenic MRSA BD Analysis Module; APAS…Clever Culture Systems · 2021
  4. This deviceK213280 BD Kiestra Methicillin-resistant Staphylococcus aureus (MRSA)…Bd Kiestra B.V. · 2023
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3DEN150059APAS Compact with Urine Analysis ModuleClever Culture Systems AG2016—
−2K183648APAS Independence with Urine Analysis ModuleClever Culture Systems AG2019—
−1K200839APAS Independence with IC Chromogenic MRSA BD Analysis Module; APAS…Clever Culture Systems2021—
0 (this device)K213280BD Kiestra Methicillin-resistant Staphylococcus aureus (MRSA) Application, BD…Bd Kiestra B.V.2023—
FIG. 1 — Lineage of K213280, 2016–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QQY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QQY device

  1. #1 K200839 APAS Independence with IC Chromogenic MRSA BD…score 8.6 · 2 generations · no Class I recall
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K200839APAS Independence with IC Chromogenic MRSA BD Analysis Module; APAS Independence with IC…
Cleared while this submission was under review
Summary page 7
…pendence with IC Chromogenic MRSA BD Analysis Module; APAS Independence with IC Chromogenic MRSA TFS/S Analysis Module Predicate 510(k) Number: K200839 1 The term “substantial equivalence” as used in this 510(k) notification is limited to the definition of substantial equi…
Clever Culture Systems2021—

Also cleared against K200839: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 7 years and passes through 3 companies; a new generation was cleared every 2.5 years on median.
  • None of the 3 ancestors has a recall.
  • 1 other device also cites its predicate K200839.

How does its category compare?

All QQY devices

QQY Culture Plate Imaging System For Qualitative Assessment Of Resistant Organisms: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · QQY

1in 2023

2021: 12023: 1
2007high 1 (2021) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QQY

Too few QQY 510(k)s in any year since 2007 to give a median.

Recalls per year · QQY

No recall names QQY since 2007.

Adverse event reports per year · QQY

No MAUDE report names QQY since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20190—00
20200—00
20211—00
20220—00
20231—00
20240—00
20250—00
20260—0—

What is it indicated for?

The BD Kiestra™ Methicillin-resistant Staphylococcus aureus (MRSA) Application is an in-vitro diagnostic software program that requires the BD Kiestra™ Laboratory Automation Solution in order to operate. The BD Kiestra™ Methicillin-resistant Staphylococcus aureus (MRSA) Application is applied to digital images of BD BBL™ CHROMagar™ MRSA II culture plates inoculated with anterior nares samples. Algorithms are applied to digital images to provide a…

Read the full statement (210 words)

The BD Kiestra™ Methicillin-resistant Staphylococcus aureus (MRSA) Application is an in-vitro diagnostic software program that requires the BD Kiestra™ Laboratory Automation Solution in order to operate.

The BD Kiestra™ Methicillin-resistant Staphylococcus aureus (MRSA) Application is applied to digital images of BD BBL™ CHROMagar™ MRSA II culture plates inoculated with anterior nares samples.

Algorithms are applied to digital images to provide a qualitative assessment of colony growth and colorimetric detection of target colonies for the detection of nasal colonization by MRSA and to serve as an aid in the prevention and control of MRSA infection. Applied algorithms provide the following results:

• “No growth”, which will be manually released individually or as a batch (with other no growth samples) by a trained microbiologist upon review of the digital plate images.

• “Growth - other” (growth without mauve color), which digital plate images will be manually reviewed by a trained microbiologist.

• “Growth MRSA Mauve” (growth with mauve color), which digital plate images will be manually reviewed by a trained microbiologist.

The assay is not intended to guide, diagnose, or monitor treatment for MRSA infections. It is not intended to provide results of susceptibility to oxacillin/methicillin.

The BD Kiestra™ Methicillin-resistant Staphylococcus aureus (MRSA) Application is indicated for use in the clinical laboratory.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K213280: BD Kiestra Methicillin-resistant Staphylococcus aureus (MRSA) Application, BD Kiestra MRSA App.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K213280

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026