510(k) Report

510(k) · Cleared

Cleared

360CAS

K213380510(k) TraditionalCleared Jan 11, 202290-day reviewClass II21 CFR 882.4560

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Kico Knee Innovation Company Pty Limited · OLO Orthopedic Stereotaxic Instrument

Cleared on Jan 11, 2022 as substantially equivalent to K162341 (Stryker Leibinger GmbH & Co KG, 2016) and 1 other predicate after a 90-day review. Its family tree reaches back 5 generations to 2000. 2 later devices descend from it.

Decided
Jan 11, 2022
Review
90 days
Class
Class II
Product code
OLO
Recalls
None
Predicates
2

Its longest line of descent runs back 5 generations to K993239 (2000). 12 ancestors in all. 2 later devices descend from it, 1 citing it directly.

  1. Root · 5 generations backK993239 Stryker Navigation System - Neuro Module, Model 6000-XXX-XXXStryker Corp. · 2000 · Recalled
  2. 4 generations backK062640 Stryker Navigation System - Cranial Module, Model 6000-650-000Stryker Instruments · 2006 · Recalled
  3. 3 generations backK141551 Profess Software, Profess Curved 70 (Degrees) Suction, Profess…Stryker Corporate · 2014 · Recalled
  4. 2 generations backK153240 Styrker OrthoMap Express Knee SystemStryker Corporate · 2016
  5. 1 generation backK162341 Stryker OrthoMap Precision Knee systemStryker Leibinger GmbH & Co KG · 2016
  6. This deviceK213380 360CASKico Knee Innovation Company Pty Limited · 2022
  7. Descendant · cites it directly · 1 of its ownK223927 360CASKico Knee Innovation Company Pty Limited · 2023
  8. Descendant · 2 generations on · 0 of its ownK242009 360CAS KneeKico Knee Innovation Company Pty, Ltd. · 2024

Most influential descendants

Showing 2 of 2 · See all
  • K223927360CASKico Knee Innovation Company Pty Limited · 2023 · cites it directly1descendant
  • K242009360CAS KneeKico Knee Innovation Company Pty, Ltd. · 2024 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K993239Stryker Navigation System - Neuro Module, Model 6000-XXX-XXXStryker Corp.20006
−4K062640Stryker Navigation System - Cranial Module, Model 6000-650-000Stryker Instruments200619
−3K141551Profess Software, Profess Curved 70 (Degrees) Suction, Profess Curved 70…Stryker Corporate20141
−2K153240Styrker OrthoMap Express Knee SystemStryker Corporate2016—
−1K162341Stryker OrthoMap Precision Knee systemStryker Leibinger GmbH & Co KG2016—
0 (this device)K213380360CASKico Knee Innovation Company Pty Limited2022—
+1K223927360CASKico Knee Innovation Company Pty Limited2023—
+2K242009360CAS KneeKico Knee Innovation Company Pty, Ltd.2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200010
200320
200510
201310
201510
201710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202310
202410
FIG. 1 — Lineage of K213380, 2000–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OLO? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OLO device

  1. #1 K240662 Spine Guidance Software (version 5.0); Xia 3/…score 23.7 · 15 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K162341Stryker OrthoMap Precision Knee system
Summary page 4
…Devices: Stryker OrthoMap Stryker OrthoMap (Primaries for Knee and Hip) Precision Knee Versatile Hip System (K162341) System (K162937) Page 1 of 13 === Page 5…
Stryker Leibinger GmbH & Co KG2016—
*K162937Stryker OrthoMap Versatile Hip System
Summary page 4
…OrthoMap Stryker OrthoMap (Primaries for Knee and Hip) Precision Knee Versatile Hip System (K162341) System (K162937) Page 1 of 13…
Stryker Corporation2017—
†K102251Dash KneeBrainlab AG2011—

Also cleared against K162341: 3 other devices →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K223927360CASKico Knee Innovation Company Pty Limited20231

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 22 years and passes through 5 companies; a new generation was cleared every 5.2 years on median.
  • 6 of the 12 ancestors have a recall of any class.
  • Of its descendants, K223927 (Kico Knee Innovation Company Pty Limited, 2023) has gone furthest, with 1 descendant of its own.
  • 3 other devices also cite its predicate K162341.

How does its category compare?

All OLO devices

OLO Orthopedic Stereotaxic Instrument: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.

FDA decisions per year · OLO

40in 2025

2009: 112010: 92011: 112012: 72013: 72014: 102015: 102016: 142017: 332018: 242019: 352020: 342021: 282022: 402023: 452024: 442025: 402026 (partial year): 42
2007high 45 (2023) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OLO

119in 2025

2009: 126 days median2010: 113 days median2011: 138 days median2012: 129 days median2013: 137 days median2014: 119 days median2015: 176 days median2016: 120 days median2017: 91 days median2018: 97 days median2019: 95 days median2020: 89 days median2021: 91 days median2022: 89 days median2023: 90 days median2024: 90 days median2025: 119 days median2026 (partial year): 109 days median
2007high 176 (2015) · low 89 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OLO

1in 2025

2010: 12011: 12012: 12014: 32015: 22016: 32017: 22018: 12019: 12020: 62022: 52023: 7, 1 Class I2024: 42025: 12026 (partial year): 6
2007high 7 (2023) · low 0 (2007)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · OLO

3,306in 2025

2008: 12009: 42010: 42011: 102012: 602013: 362014: 2452015: 4662016: 7502017: 1,0762018: 1,2302019: 1,5852020: 2,7462021: 1,6962022: 1,5682023: 1,4932024: 2,3532025: 3,306
2007high 3,306 (2025) · low 0 (2007)2025

MAUDE reports naming product code OLO, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—01
20091112604
2010911314
201111138110
20127129160
20137137036
2014101193245
2015101762466
2016141203750
2017339121,076
2018249711,230
2019359511,585
2020348962,746
2021289101,696
2022408951,568
202345907 (1)1,493
2024449042,353
20254011913,306
2026421096—

What is it indicated for?

The 360CAS is intended to be used as a planning and intraoperative guidance system to enable open or percutaneous image guided surgical procedures. The 360CAS is indicated for patients undergoing orthopaedic surgery and where reference to a rigid anatomical structure, such as the pelvis, femur, or tibia, can be identified. The 360CAS Knee is indicated for the following surgical procedures: - Total Knee Arthroplasty (TKA) - For conditions of the knee…

Read the full statement (129 words)

The 360CAS is intended to be used as a planning and intraoperative guidance system to enable open or percutaneous image guided surgical procedures.

The 360CAS is indicated for patients undergoing orthopaedic surgery and where reference to a rigid anatomical structure, such as the pelvis, femur, or tibia, can be identified.

The 360CAS Knee is indicated for the following surgical procedures:

- Total Knee Arthroplasty (TKA)

- For conditions of the knee joint in which the use of computer assisted surgery may be appropriate

The 360CAS Hip is indicated for the following surgical procedures:

- Total Hip Arthroplasty (THA) e.g., open or minimally invasive, where a posterior or anterior approach is used

- For conditions of the hip joint in which the use of computer assisted surgery may be appropriate

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K213380: 360CAS.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K213380

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026