Yushan X-Ray Flat Panel Detector with DROC

K220510510(k) TraditionalCleared Apr 14, 202251-day reviewClass II21 CFR 892.1680

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Innocare Optoelectronics Corp. · MQB Solid State X-Ray Imager (Flat Panel/Digital Imager)

Cleared on Apr 14, 2022 as substantially equivalent to K201528 (Innocare Optoelectronics Corp., 2020) and 1 other predicate after a 51-day review. Its family tree reaches back 13 generations to 1998. 5 later devices descend from it.

Decided
Apr 14, 2022
Review
51 days
Class
Class II
Product code
MQB
Recalls
None
Predicates
2

Its longest line of descent runs back 13 generations to K981556 (1998). 20 ancestors in all. 5 later devices descend from it, 4 citing it directly.

  1. Root · 13 generations backK981556 Canon X-Ray Digital Camera Cxdi-11Canon USA, Inc. · 1998
  2. 9 generations between
  3. 3 generations backK142003 FDR D-Evo II Flat Panel Detector SystemFujifilm Medical System U.S.A., Inc. · 2014
  4. 2 generations backK191939 Yushan X-Ray Flat Panel DetectorInnocare Optoelectronics Corp. · 2019
  5. 1 generation backK201528 Yushan X-Ray Flat Panel Detector with DROCInnocare Optoelectronics Corp. · 2020
  6. This deviceK220510 Yushan X-Ray Flat Panel Detector with DROCInnocare Optoelectronics Corp. · 2022
  7. Descendant · cites it directly · 1 of its ownK243171 Yushan X-Ray Flat Panel DetectorInnocare Optoelectronics Corp. · 2024
  8. Descendant · cites it directly · 1 of its ownK223009 Wireless/Wired X-Ray Flat Panel DetectorsAllengers Medical Systems Limited · 2022
  9. Descendant · cites it directly · 0 of its ownK250211 Yushan X-Ray Flat Panel DetectorInnocare Optoelectronics Corp. · 2025
  10. Descendant · 2 generations on · 0 of its ownK243734 Wireless/ Wired X-Ray Flat Panel DetectorsAllengers Medical Systems Limited · 2025
  11. Descendant · cites it directly · 0 of its ownK240771 PRORAD X-Ray Flat Panel Detector with DROCPrognosys Medical Systems Private Limited · 2024
Show all 13 generations
  1. Root · 13 generations backK981556 Canon X-Ray Digital Camera Cxdi-11Canon USA, Inc. · 1998
  2. 12 generations backK992547 Canon X-Ray Digital Camera, Model Cxdi-22Canon USA, Inc. · 1999
  3. 11 generations backK023750 Cannon Digital Radiography Model Cxdi-40GCanon USA, Inc. · 2002
  4. 10 generations backK031447 Canon, Digital Radiography, Model Cxdi-50GCanon, Inc. · 2003
  5. 9 generations backK060433 Digital Radiography Cxdi-50CCanon, Inc. · 2006
  6. 8 generations backK091545 Digital Radiography Cxdi-60CCanon, Inc. · 2009
  7. 7 generations backK102012 Digital RadiographyCanon Inc. -Medical Equipment Group · 2010 · Recalled
  8. 6 generations backK103596 Wireless/Wired FDR D-Evo Flat Panel DetectorFujifilm Medical Systems U.S.A, Inc. · 2011
  9. 5 generations backK111548 Wireless/Wired FDR D-Evo Flat Pancel Detector System Model DR-ID600…Fujifilm Medical System U.S.A., Inc. · 2011
  10. 4 generations backK132509 FDR D-Evo Flat Panel Detector SystemFujifilm Medical Systems U.S.A, Inc. · 2013
  11. 3 generations backK142003 FDR D-Evo II Flat Panel Detector SystemFujifilm Medical System U.S.A., Inc. · 2014
  12. 2 generations backK191939 Yushan X-Ray Flat Panel DetectorInnocare Optoelectronics Corp. · 2019
  13. 1 generation backK201528 Yushan X-Ray Flat Panel Detector with DROCInnocare Optoelectronics Corp. · 2020
  14. This deviceK220510 Yushan X-Ray Flat Panel Detector with DROCInnocare Optoelectronics Corp. · 2022

Most influential descendants

Showing 5 of 5 · See all
  • K243171Yushan X-Ray Flat Panel DetectorInnocare Optoelectronics Corp. · 2024 · cites it directly1descendant
  • K223009Wireless/Wired X-Ray Flat Panel DetectorsAllengers Medical Systems Limited · 2022 · cites it directly1descendant
  • K250211Yushan X-Ray Flat Panel DetectorInnocare Optoelectronics Corp. · 2025 · cites it directly0descendants
  • K243734Wireless/ Wired X-Ray Flat Panel DetectorsAllengers Medical Systems Limited · 2025 · 2 generations on0descendants
  • K240771PRORAD X-Ray Flat Panel Detector with DROCPrognosys Medical Systems Private Limited · 2024 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−13K981556Canon X-Ray Digital Camera Cxdi-11Canon USA, Inc.1998—
−12K992547Canon X-Ray Digital Camera, Model Cxdi-22Canon USA, Inc.1999—
−11K023750Cannon Digital Radiography Model Cxdi-40GCanon USA, Inc.2002—
−10K031447Canon, Digital Radiography, Model Cxdi-50GCanon, Inc.2003—
−9K060433Digital Radiography Cxdi-50CCanon, Inc.2006—
−8K091545Digital Radiography Cxdi-60CCanon, Inc.2009—
−7K102012Digital RadiographyCanon Inc. -Medical Equipment Group20101
−6K103596Wireless/Wired FDR D-Evo Flat Panel DetectorFujifilm Medical Systems U.S.A, Inc.2011—
−5K111548Wireless/Wired FDR D-Evo Flat Pancel Detector System Model DR-ID600 W/DR-ID611SEFujifilm Medical System U.S.A., Inc.2011—
−4K132509FDR D-Evo Flat Panel Detector SystemFujifilm Medical Systems U.S.A, Inc.2013—
−3K142003FDR D-Evo II Flat Panel Detector SystemFujifilm Medical System U.S.A., Inc.2014—
−2K191939Yushan X-Ray Flat Panel DetectorInnocare Optoelectronics Corp.2019—
−1K201528Yushan X-Ray Flat Panel Detector with DROCInnocare Optoelectronics Corp.2020—
0 (this device)K220510Yushan X-Ray Flat Panel Detector with DROCInnocare Optoelectronics Corp.2022—
+1K243171Yushan X-Ray Flat Panel DetectorInnocare Optoelectronics Corp.2024—
+1K223009Wireless/Wired X-Ray Flat Panel DetectorsAllengers Medical Systems Limited2022—
+1K250211Yushan X-Ray Flat Panel DetectorInnocare Optoelectronics Corp.2025—
+2K243734Wireless/ Wired X-Ray Flat Panel DetectorsAllengers Medical Systems Limited2025—
+1K240771PRORAD X-Ray Flat Panel Detector with DROCPrognosys Medical Systems Private Limited2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200220
200310
200410
200810
200910
201010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202210
202420
202520
FIG. 1 — Lineage of K220510, 1998–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MQB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MQB device

  1. #1 K201528 Yushan X-Ray Flat Panel Detector with DROCscore 21.5 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K201528Yushan X-Ray Flat Panel Detector with DROC
Summary page 4
…EVICE Substantial equivalence to the following predicate device is as follows: Trade/Device Name: Yushan X-Ray Flat Panel Detector with DROC FDA 510(k) clearance number: K201528 Manufacturer: InnoCare Optoelectronics Corp. Decision Date: 10/11/2020 Regulation description: Stationary x-ray system. Review pa…
Innocare Optoelectronics Corp.2020—
*K132509FDR D-Evo Flat Panel Detector System
Summary page 5
…1of7 Device class: Class II Trade/Device Name: FDR D-EVO FLAT PANEL DETECTOR SYSTEM FDA 510(k) clearance number: K132509 Manufacturer: FUJIFILM MEDICAL SYSTEMS USA, INC. Decision Date: 11/25/2013 Regulation description: Stationary x-ray system. Revie…
Fujifilm Medical Systems U.S.A, Inc.2013—

Also cleared against K201528: 5 other devices →

What descends from it? (5)

4 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K243171Yushan X-Ray Flat Panel DetectorInnocare Optoelectronics Corp.20241
K223009Wireless/Wired X-Ray Flat Panel DetectorsAllengers Medical Systems Limited20221
K250211Yushan X-Ray Flat Panel DetectorInnocare Optoelectronics Corp.20250
K240771PRORAD X-Ray Flat Panel Detector with DROCPrognosys Medical Systems Private Limited20240

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 24 years and passes through 6 companies; a new generation was cleared every 1.2 years on median.
  • 3 of the 20 ancestors have a recall of any class.
  • Of its descendants, K243171 (Innocare Optoelectronics Corp., 2024) has gone furthest, with 1 descendant of its own.
  • 5 other devices also cite its predicate K201528.

How does its category compare?

All MQB devices

MQB Solid State X-Ray Imager (Flat Panel/Digital Imager): FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.

FDA decisions per year · MQB

8in 2025

2007: 132008: 82009: 152010: 112011: 242012: 222013: 212014: 322015: 212016: 222017: 312018: 162019: 222020: 192021: 212022: 312023: 102024: 82025: 82026 (partial year): 3
2007high 32 (2014) · low 8 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MQB

127in 2025

2007: 22 days median2008: 15 days median2009: 57 days median2010: 116 days median2011: 102 days median2012: 80 days median2013: 105 days median2014: 102 days median2015: 81 days median2016: 92 days median2017: 30 days median2018: 30 days median2019: 30 days median2020: 28 days median2021: 48 days median2022: 48 days median2023: 30 days median2024: 187 days median2025: 127 days median2026 (partial year): 245 days median
2007high 245 (2026) · low 15 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MQB

1in 2025

2007: 152008: 362009: 192010: 142011: 102012: 82013: 62017: 12018: 42019: 12020: 42021: 12025: 12026 (partial year): 1
2007high 36 (2008) · low 0 (2014)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MQB

141in 2025

2007: 252008: 302009: 342010: 392011: 1012012: 2672013: 1592014: 292015: 212016: 262017: 202018: 842019: 452020: 92021: 262022: 132023: 512024: 912025: 141
2007high 267 (2012) · low 9 (2020)2025

MAUDE reports naming product code MQB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200713221525
20088153630
200915571934
2010111161439
20112410210101
201222808267
2013211056159
201432102029
20152181021
20162292026
20173130120
20181630484
20192230145
2020192849
20212148126
20223148013
20231030051
20248187091
202581271141
202632451—

What is it indicated for?

The Wired Yushan X-Ray Flat Panel Detector is intended to capture for display radiographic images of human anatomy.

It is intended for use in general projection radiographic applications wherever conventional film/screen or CR systems may be used. The Yushan X-Ray Flat Panel Detector is not intended for mammography, fluoroscopy, tomography, and angiography applications. The use of this product is not recommended for pregnant women and the risk of radioactivity must be evaluated by a physician.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K220510: Yushan X-Ray Flat Panel Detector with DROC.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K220510

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026