K220728510(k) TraditionalCleared Jun 2, 2023445-day reviewClass II21 CFR 864.7290

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Siemens Healthcare Diagnostics Products GmbH · GGP Test, Qualitative And Quantitative Factor Deficiency

Cleared on Jun 2, 2023 as substantially equivalent to K962675 (American Bioproducts Co., 1996) after a 445-day review. Its family tree reaches back 2 generations to 1986.

Decided
Jun 2, 2023
Review
445 days
Class
Class II
Product code
GGP
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K861417 (1986). No later device cites it as a predicate yet.

  1. Root · 2 generations backK861417 Assera-Plate VWF KitAmerican Bioproducts Co. · 1986
  2. 1 generation backK962675 Sta - Liatest VWF Test KitAmerican Bioproducts Co. · 1996 · Recalled
  3. This deviceK220728 vWF AgSiemens Healthcare Diagnostics Products GmbH · 2023
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K861417Assera-Plate VWF KitAmerican Bioproducts Co.1986—
−1K962675Sta - Liatest VWF Test KitAmerican Bioproducts Co.19961
0 (this device)K220728vWF AgSiemens Healthcare Diagnostics Products GmbH2023—
FIG. 1 — Lineage of K220728, 1986–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GGP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GGP device

  1. #1 K251440 CRYOcheck Chromogenic Factor VIIIscore 10.5 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K962675Sta - Liatest VWF Test Kit
Summary page 4
…eficiency Regulatory Class: Class II 510(k) Review Panel Hematology (81) 3. Predicate Device Name of Device: STA® - Liatest® VWF:Ag (K962675) Regulation Number: 21 CFR 864.7290 Regulation Description: Factor deficiency test Product Code: GJ…
American Bioproducts Co.19961

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 37 years and passes through 2 companies; a new generation was cleared every 26.6 years on median.
  • 1 of the 2 ancestors has a recall of any class.

How does its category compare?

All GGP devices

GGP Test, Qualitative And Quantitative Factor Deficiency: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · GGP

1in 2025

2007: 32008: 22009: 12011: 12014: 12018: 12019: 12020: 22022: 22023: 22025: 1
2007high 3 (2007) · low 0 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GGP

153in 2007

2007: 153 days median
2007high 153 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GGP

1in 2017

2007: 22010: 12012: 22015: 22017: 12026 (partial year): 1
2007high 2 (2007) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GGP

3in 2025

2012: 42014: 12015: 12017: 32018: 32019: 12021: 22022: 42025: 3
2007high 4 (2012) · low 0 (2007)2025

MAUDE reports naming product code GGP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007315320
20082—00
20091—00
20100—10
20111—00
20120—24
20130—00
20141—01
20150—21
20160—00
20170—13
20181—03
20191—01
20202—00
20210—02
20222—04
20232—00
20240—00
20251—03
20260—1—

What is it indicated for?

In-vitro diagnostic automated assay for the quantitative determination of the von Willebrand antigen (VWF:Ag) in human plasma collected from venous blood samples in 3.2% sodium citrated tubes on the SYSMEX® CS-2500 analyzer.

As an aid used in the evaluation of patients aged 4 weeks and older with suspected or confirmed von Willebrand factor disorders and intended for prescription use.

Results of this test should always be interpreted in conjunction with the patient’s medical history, clinical presentation and other laboratory findings.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K220728: vWF Ag.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K220728

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026