510(k) Report

510(k) · Cleared

Cleared

HemosIL Chromogenic Factor IX

K230852510(k) TraditionalCleared Dec 13, 2023260-day reviewClass II21 CFR 864.7290

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Instrumentation Laboratory Company · GGP Test, Qualitative And Quantitative Factor Deficiency

Cleared on Dec 13, 2023 as substantially equivalent to K031829 (Instrumentation Laboratory CO, 2003) after a 260-day review. Its family tree reaches back 2 generations to 1989.

Decided
Dec 13, 2023
Review
260 days
Class
Class II
Product code
GGP
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K893524 (1989). 3 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2000: 1 other ancestorK893524 · Factor IX Deficient Plasma · Medical Diagnostic Technologies, Inc. · 1989K031829 · Hemosil Factor IX Deficient Plasma · Instrumentation Laboratory CO · 20031990200020102020
Other ancestors, by generation 2 generations back: 1 other ancestor K031829 · Hemosil Factor IX Deficient Plasma · Instrumentation Laboratory CO · 2003K893524 · Factor IX Deficient Plasma · Medical Diagnostic Technologies, Inc. · 19890
  1. Root · 2 generations backK893524 Factor IX Deficient PlasmaMedical Diagnostic Technologies, Inc. · 1989
  2. 1 generation backK031829 Hemosil Factor IX Deficient PlasmaInstrumentation Laboratory CO · 2003
  3. This deviceK230852 HemosIL Chromogenic Factor IXInstrumentation Laboratory Company · 2023
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K893524Factor IX Deficient PlasmaMedical Diagnostic Technologies, Inc.1989—
−1K031829Hemosil Factor IX Deficient PlasmaInstrumentation Laboratory CO2003—
0 (this device)K230852HemosIL Chromogenic Factor IXInstrumentation Laboratory Company2023—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200010
FIG. 1 — Lineage of K230852, 1989–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GGP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GGP device

  1. #1 K251440 CRYOcheck Chromogenic Factor VIIIscore 10.5 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K031829Hemosil Factor IX Deficient Plasma
Summary page 4
…Product Code GGP Classification Panel Hematology (81) Predicate Device K031829 HemosIL Factor IX deficient plasma Device Description Factor IX activity in a patient’s plasm…
Instrumentation Laboratory CO2003—

Also cleared against K031829: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 34 years and passes through 3 companies; a new generation was cleared every 20.4 years on median.
  • 1 of the 3 ancestors has a recall of any class.
  • 1 other device also cites its predicate K031829.

How does its category compare?

All GGP devices

GGP Test, Qualitative And Quantitative Factor Deficiency: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · GGP

1in 2025

2007: 32008: 22009: 12011: 12014: 12018: 12019: 12020: 22022: 22023: 22025: 1
2007high 3 (2007) · low 0 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GGP

153in 2007

2007: 153 days median
2007high 153 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GGP

1in 2017

2007: 22010: 12012: 22015: 22017: 12026 (partial year): 1
2007high 2 (2007) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GGP

3in 2025

2012: 42014: 12015: 12017: 32018: 32019: 12021: 22022: 42025: 3
2007high 4 (2012) · low 0 (2007)2025

MAUDE reports naming product code GGP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007315320
20082—00
20091—00
20100—10
20111—00
20120—24
20130—00
20141—01
20150—21
20160—00
20170—13
20181—03
20191—01
20202—00
20210—02
20222—04
20232—00
20240—00
20251—03
20260—1—

What is it indicated for?

HemosIL Chromogenic Factor IX is an automated assay for the photometric, quantitative determination of factor IX activity in 3.2% citrated plasma on the ACL TOP® Family and ACL TOP Family 50 Series in the laboratory setting by a healthcare professional. HemosIL Chromogenic Factor IX is indicated for use on patients when identifying factor IX deficiency or measuring factor IX activity from patients on replacement therapy.

For adult population only. For prescription use only.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K230852: HemosIL Chromogenic Factor IX.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K230852

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026