510(k) · Cleared
ClearedVivid E80, Vivid E90, Vivid E95
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Ge Medical Systems Ultrasound And · IYN System, Imaging, Pulsed Doppler, Ultrasonic
Cleared on Jul 22, 2022 as substantially equivalent to K202658 (GE Medical Systems Ultrasound and Primary Care Diagnostics, 2021) after a 119-day review. Its family tree reaches back 25 generations to 1995. 2 later devices descend from it.
- Decided
- Jul 22, 2022
- Review
- 119 days
- Class
- Class II
- Product code
- IYN
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 25 generations to K935595 (1995). 223 ancestors in all, the oldest K863700 (1987). 2 later devices descend from it, 2 citing it directly.
- Root · 25 generations backK935595 Acuson Model 3001Acuson Corp. · 1995
- 21 generations between
- 3 generations backK181685 Vivid E80, Vivid E90, Vivid E95GE Medical Systems Ultrasound and Primary Care Diagnostics · 2018
- 2 generations backK200743 Vivid E80/ Vivid E90/ Vivid E95Ge Medical Systems Ultrasound And · 2020
- 1 generation backK202658 Vivid E80/ Vivid E90/ Vivid E95GE Medical Systems Ultrasound and Primary Care Diagnostics · 2021
- This deviceK220882 Vivid E80, Vivid E90, Vivid E95Ge Medical Systems Ultrasound And · 2022
- Descendant · cites it directly · 0 of its ownK261623 EchoPAC Software Only / EchoPAC Plug-in (v211)GE Medical Systems Ultrasound and Primary Care Diagnostics · 2026
- Descendant · cites it directly · 0 of its ownK251169 Vivid PioneerGE Medical Systems Ultrasound and Primary Care Diagnostics · 2025
Show all 25 generations
- Root · 25 generations backK935595 Acuson Model 3001Acuson Corp. · 1995
- 24 generations backK973767 Harmonic Imaging with ContrastAcuson Corp. · 1997
- 23 generations backK022567 Sequoia Signature II Diagnostic Ultrasound SystemAcuson Corp. · 2002
- 22 generations backK032114 Sequoia 8.0 Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2003
- 21 generations backK041319 Sequoia Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2004
- 20 generations backK042770 Modification to Acuson CV70 Cardiovascular SystemSiemens Medical Solutions USA, Inc. · 2004 · Recalled
- 19 generations backK050240 Modification to Acuson CV70 Cardiovascular SystemSiemens Medical Solutions USA, Inc. · 2005 · Recalled
- 18 generations backK052894 Sonoline G60 S Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2005 · Recalled
- 17 generations backK063138 Modification to Acuson Antares Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2006
- 16 generations backK063803 Acuson Antares Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc., Ultrasound DI · 2007 · Recalled
- 15 generations backK072786 Acuson S2000 Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2007
- 14 generations backK083095 Sonixtouch Ultrasound SystemUltrasonix Medical Corporation · 2008
- 13 generations backK092271 GE Logiq E9 BT2010 Diagnostic Ultrasound System, Model 5205000-3…GE Healthcare · 2009 · Recalled
- 12 generations backK110943 Logiq E9GE Healthcare · 2011 · Recalled
- 11 generations backK113690 GE Logiq I, Logiq E and Vivid EGE Healthcare · 2011 · Recalled
- 10 generations backK123564 Logiq E9 Diagnostic Ultrasound SystemGE Healthcare · 2012 · Recalled
- 9 generations backK131514 GE Vivid E9 Diagnostic Ultrasound Imaging SystemGe Vingmed Ultrasound AS · 2013 · Recalled
- 8 generations backK141093 6VT-D Ultrasound TransducerGe Vingmed Ultrasound AS · 2014
- 7 generations backK142323 Vivid S60 Diagnostic Ultrasound System, Vivid S70 Diagnostic…Ge Medical Systems Israel, Ltd. · 2014 · Recalled
- 6 generations backK150087 Vivid E80 Diagnostic Ultrasound Imaging System, Vivid E90 Diagnostic…Ge Vingmed Ultrasound AS · 2015 · Recalled
- 5 generations backK170823 Vivid E80, Vivid E90, Vivid E95GE Medical Systems Ultrasound and Primary Care Diagnostics · 2017 · Recalled
- 4 generations backK173341 Vivid E80, Vivid E90, Vivid E95GE Medical Systems · 2017 · Recalled
- 3 generations backK181685 Vivid E80, Vivid E90, Vivid E95GE Medical Systems Ultrasound and Primary Care Diagnostics · 2018
- 2 generations backK200743 Vivid E80/ Vivid E90/ Vivid E95Ge Medical Systems Ultrasound And · 2020
- 1 generation backK202658 Vivid E80/ Vivid E90/ Vivid E95GE Medical Systems Ultrasound and Primary Care Diagnostics · 2021
- This deviceK220882 Vivid E80, Vivid E90, Vivid E95Ge Medical Systems Ultrasound And · 2022
Most influential descendants
Showing 2 of 2 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −25 | K935595 | Acuson Model 3001 | Acuson Corp. | 1995 | — |
| −24 | K973767 | Harmonic Imaging with Contrast | Acuson Corp. | 1997 | — |
| −23 | K022567 | Sequoia Signature II Diagnostic Ultrasound System | Acuson Corp. | 2002 | — |
| −22 | K032114 | Sequoia 8.0 Diagnostic Ultrasound System | Siemens Medical Solutions USA, Inc. | 2003 | — |
| −21 | K041319 | Sequoia Diagnostic Ultrasound System | Siemens Medical Solutions USA, Inc. | 2004 | — |
| −20 | K042770 | Modification to Acuson CV70 Cardiovascular System | Siemens Medical Solutions USA, Inc. | 2004 | 1 |
| −19 | K050240 | Modification to Acuson CV70 Cardiovascular System | Siemens Medical Solutions USA, Inc. | 2005 | 1 |
| −18 | K052894 | Sonoline G60 S Ultrasound System | Siemens Medical Solutions USA, Inc. | 2005 | 1 |
| −17 | K063138 | Modification to Acuson Antares Ultrasound System | Siemens Medical Solutions USA, Inc. | 2006 | — |
| −16 | K063803 | Acuson Antares Diagnostic Ultrasound System | Siemens Medical Solutions USA, Inc., Ultrasound DI | 2007 | 9 |
| −15 | K072786 | Acuson S2000 Ultrasound System | Siemens Medical Solutions USA, Inc. | 2007 | — |
| −14 | K083095 | Sonixtouch Ultrasound System | Ultrasonix Medical Corporation | 2008 | — |
| −13 | K092271 | GE Logiq E9 BT2010 Diagnostic Ultrasound System, Model 5205000-3, 5205000-4 | GE Healthcare | 2009 | 1 |
| −12 | K110943 | Logiq E9 | GE Healthcare | 2011 | 2 |
| −11 | K113690 | GE Logiq I, Logiq E and Vivid E | GE Healthcare | 2011 | 1 |
| −10 | K123564 | Logiq E9 Diagnostic Ultrasound System | GE Healthcare | 2012 | 1 |
| −9 | K131514 | GE Vivid E9 Diagnostic Ultrasound Imaging System | Ge Vingmed Ultrasound AS | 2013 | 2 |
| −8 | K141093 | 6VT-D Ultrasound Transducer | Ge Vingmed Ultrasound AS | 2014 | — |
| −7 | K142323 | Vivid S60 Diagnostic Ultrasound System, Vivid S70 Diagnostic Ultrasound System | Ge Medical Systems Israel, Ltd. | 2014 | 3 |
| −6 | K150087 | Vivid E80 Diagnostic Ultrasound Imaging System, Vivid E90 Diagnostic… | Ge Vingmed Ultrasound AS | 2015 | 6 |
| −5 | K170823 | Vivid E80, Vivid E90, Vivid E95 | GE Medical Systems Ultrasound and Primary Care Diagnostics | 2017 | 3 |
| −4 | K173341 | Vivid E80, Vivid E90, Vivid E95 | GE Medical Systems | 2017 | 3 |
| −3 | K181685 | Vivid E80, Vivid E90, Vivid E95 | GE Medical Systems Ultrasound and Primary Care Diagnostics | 2018 | — |
| −2 | K200743 | Vivid E80/ Vivid E90/ Vivid E95 | Ge Medical Systems Ultrasound And | 2020 | — |
| −1 | K202658 | Vivid E80/ Vivid E90/ Vivid E95 | GE Medical Systems Ultrasound and Primary Care Diagnostics | 2021 | — |
| 0 (this device) | K220882 | Vivid E80, Vivid E90, Vivid E95 | Ge Medical Systems Ultrasound And | 2022 | — |
| +1 | K261623 | EchoPAC Software Only / EchoPAC Plug-in (v211) | GE Medical Systems Ultrasound and Primary Care Diagnostics | 2026 | — |
| +1 | K251169 | Vivid Pioneer | GE Medical Systems Ultrasound and Primary Care Diagnostics | 2025 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1987 | 1 | 0 |
| 1989 | 2 | 0 |
| 1990 | 1 | 0 |
| 1992 | 1 | 0 |
| 1993 | 1 | 0 |
| 1994 | 6 | 0 |
| 1995 | 9 | 0 |
| 1996 | 6 | 0 |
| 1997 | 10 | 0 |
| 1998 | 5 | 0 |
| 1999 | 12 | 0 |
| 2000 | 9 | 0 |
| 2001 | 9 | 0 |
| 2002 | 14 | 0 |
| 2003 | 13 | 0 |
| 2004 | 18 | 0 |
| 2005 | 10 | 0 |
| 2006 | 14 | 0 |
| 2007 | 10 | 0 |
| 2008 | 8 | 0 |
| 2009 | 6 | 0 |
| 2010 | 9 | 0 |
| 2011 | 7 | 0 |
| 2012 | 10 | 0 |
| 2013 | 3 | 0 |
| 2014 | 1 | 0 |
| 2015 | 2 | 0 |
| 2016 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2025 | 1 | 0 |
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in IYN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new IYN device
- #1 K240850 EPIQ Series Diagnostic Ultrasound Systems…score 32.1 · 24 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K202658 | Vivid E80/ Vivid E90/ Vivid E95Summary page 4…ho Imaging System, 21CFR 892.1560, 90-IYO; Diagnostic Ultrasound Transducer, 21 CFR 892.1570, 90-ITX Primary Predicate Device: Vivid E95 (K202658), Diagnostic Ultrasound System Classification Names: Class II Product Code(s): Ultrasonic Pulsed Doppler Imagi… | 2021 |
| † | K211488 | Logiq E10 | 2021 |
| † | K202132 | Venue | 2020 |
| † | K181685 | Vivid E80, Vivid E90, Vivid E95 | 2018 |
| † | K200179 | Collaboration Live | 2020 |
| † | K150193 | Customer Remote Console (CRC) | 2015 |
What descends from it? (2)
2 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 27 years and passes through 10 companies; a new generation was cleared every 11 months on median.
- 64 of the 223 ancestors have a recall of any class.
- Of its descendants, K261623 (GE Medical Systems Ultrasound and Primary Care Diagnostics, 2026) has gone furthest, with 0 descendants of its own.
- 1 other device also cites its predicate K202658.
How does its category compare?
All IYN devicesIYN System, Imaging, Pulsed Doppler, Ultrasonic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.
FDA decisions per year · IYN
57in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · IYN
124in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · IYN
10in 2025
Class I (1 since 2007) Class II/III not classified
Adverse event reports per year · IYN
610in 2025
MAUDE reports naming product code IYN, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 13 | 26 | 16 | 3 |
| 2008 | 25 | 18 | 12 | 2 |
| 2009 | 18 | 29 | 8 | 9 |
| 2010 | 29 | 67 | 10 | 17 |
| 2011 | 39 | 46 | 8 | 18 |
| 2012 | 43 | 37 | 3 | 20 |
| 2013 | 51 | 60 | 8 | 18 |
| 2014 | 56 | 39 | 2 | 48 |
| 2015 | 54 | 55 | 3 | 116 |
| 2016 | 60 | 56 | 2 | 145 |
| 2017 | 64 | 83 | 0 | 146 |
| 2018 | 59 | 85 | 7 | 85 |
| 2019 | 47 | 79 | 0 | 59 |
| 2020 | 57 | 72 | 4 | 67 |
| 2021 | 46 | 105 | 8 | 213 |
| 2022 | 53 | 105 | 10 | 186 |
| 2023 | 44 | 115 | 4 | 229 |
| 2024 | 50 | 119 | 1 | 266 |
| 2025 | 57 | 124 | 10 | 610 |
| 2026 | 44 | 107 | 2 (1) | — |
What is it indicated for?
Vivid E80/Vivid E90/Vivid E95 is a general-purpose ultrasound system, specialized for use in cardiac imaging. It is intended for use by, or under the direction of a qualified and trained physician for ultrasound imaging, measurement, display and analysis of the human body and fluid. The device is intended for use in a hospital environment including echo lab, other hospital settings, operating room, Cath lab and EP lab or in private medical offices. The…
Read the full statement (163 words)
Vivid E80/Vivid E90/Vivid E95 is a general-purpose ultrasound system, specialized for use in cardiac imaging. It is intended for use by, or under the direction of a qualified and trained physician for ultrasound imaging, measurement, display and analysis of the human body and fluid. The device is intended for use in a hospital environment including echo lab, other hospital settings, operating room, Cath lab and EP lab or in private medical offices. The systems support the following clinical applications: Fetal/Obstetrics, Abdominal (including renal, GYN), Pediatric, Small Organ (breast, testes, thyroid), Neonatal Cephalic, Adult Cephalic, Cardiac (adult and pediatric), Peripheral Vascular, Musculo-skeletal Conventional, Musculo-skeletal Superficial, Urology (including prostate), Transesophageal, Transvaginal, Transrectal, Intra-cardiac and Intra-luminal, Interventional Guidance (including Biopsy, Vascular Access), Thoracic/Pleural and Intraoperative (vascular). Modes of operation include: 3D, Real time (RT) 3D (4D), B, M, PW Doppler, CW Doppler, Color Doppler, Color M Doppler, Power Doppler, Harmonic Imaging, Coded Pulse and Combined modes: B/M, B/Color M, B/PWD or CWD, B/Color/PWD or CWD, B/Power/PWD.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K220882 · printed Nov 6, 2026
Cite this page
510(k) Report. “K220882: Vivid E80, Vivid E90, Vivid E95.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K220882
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026