Steriking Packaging for Medical Devices

K221016510(k) SpecialCleared May 5, 202230-day reviewClass II21 CFR 880.6850

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Wipak OY · FRG Wrap, Sterilization

Cleared on May 5, 2022 as substantially equivalent to K210810 (Wipak OY, 2022) after a 30-day review. Its family tree reaches back 2 generations to 1995. 1 later device descends from it.

Decided
May 5, 2022
Review
30 days
Class
Class II
Product code
FRG
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K953776 (1995). 1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2024: 1 descendant clearedK953776 · Steriking Sterilization Pouches & Rolls · Wihuri OY · 1995K210810 · Steiking Packaging for Medical Devices · Wipak OY · 20221995200020052010201520202025
Descendants, by generation 1 generation forward: 1 descendant K210810 · Steiking Packaging for Medical Devices · Wipak OY · 2022K953776 · Steriking Sterilization Pouches & Rolls · Wihuri OY · 19950
  1. Root · 2 generations backK953776 Steriking Sterilization Pouches & RollsWihuri OY · 1995
  2. 1 generation backK210810 Steiking Packaging for Medical DevicesWipak OY · 2022
  3. This deviceK221016 Steriking Packaging for Medical DevicesWipak OY · 2022
  4. Descendant · cites it directly · 0 of its ownK232625 Steriking® Pouch for Robotic InstrumentsWipak OY · 2024

Most influential descendants

Showing 1 of 1 · See all
  • K232625Steriking® Pouch for Robotic InstrumentsWipak OY · 2024 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K953776Steriking Sterilization Pouches & RollsWihuri OY1995—
−1K210810Steiking Packaging for Medical DevicesWipak OY2022—
0 (this device)K221016Steriking Packaging for Medical DevicesWipak OY2022—
+1K232625Steriking® Pouch for Robotic InstrumentsWipak OY2024—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202410
FIG. 1 — Lineage of K221016, 1995–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FRG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FRG device

  1. #1 K234050 HALYARD® ONE-STEP® Sterilization Wrap…score 15.8 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K210810Steiking Packaging for Medical Devices
Summary page 4
…usual name, and the Regulation number (21 CFR 880.6850) classification Product code (FRG) name a3 Identification of the legally K210810, Steriking Packaging for Medical Devices marketed device to which the submitter claims equivalence (predicate…
Wipak OY2022—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K232625Steriking® Pouch for Robotic InstrumentsWipak OY20240

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 27 years and passes through 2 companies; a new generation was cleared every 26.3 years on median.
  • None of the 2 ancestors has a recall.
  • Of its descendants, K232625 (Wipak OY, 2024) has gone furthest, with 0 descendants of its own.

How does its category compare?

All FRG devices

FRG Wrap, Sterilization: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.

FDA decisions per year · FRG

9in 2025

2007: 32008: 22009: 42010: 42011: 62012: 102013: 62014: 82015: 122016: 92017: 92018: 52019: 92020: 52021: 42022: 92023: 92024: 112025: 92026 (partial year): 4
2007high 12 (2015) · low 2 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FRG

151in 2025

2007: 182 days median2009: 171 days median2010: 213 days median2011: 110 days median2012: 133 days median2013: 146 days median2014: 177 days median2015: 196 days median2016: 131 days median2017: 260 days median2018: 150 days median2019: 258 days median2020: 122 days median2021: 170 days median2022: 217 days median2023: 230 days median2024: 182 days median2025: 151 days median2026 (partial year): 247 days median
2007high 260 (2017) · low 110 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FRG

2in 2022

2013: 22017: 292020: 142022: 2
2007high 29 (2017) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FRG

18in 2025

2007: 12008: 22009: 22011: 122012: 42013: 52014: 132015: 92016: 202017: 72018: 222019: 102020: 212021: 92022: 42023: 132024: 212025: 18
2007high 22 (2018) · low 0 (2010)2025

MAUDE reports naming product code FRG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007318201
20082—02
2009417102
2010421300
20116110012
20121013304
2013614625
20148177013
20151219609
20169131020
20179260297
20185150022
20199258010
202051221421
2021417009
2022921724
20239230013
202411182021
20259151018
202642470—

What is it indicated for?

Steriking Packaging for Medical Devices serve as an enclosure for medical devices during steam sterilization that maintains the sterility of the enclosed medical devices until use of the medical devices with a combined weight of metal and plastics of 2.6 pounds or less. The recommended sterilization cycles are as follows: Pre-vacuum steam at 132oC for 4 minutes; Drying time of 20 minutes Pre-vacuum steam at 135oC for 3 minutes; Drying time of 16 minutes…

Read the full statement (258 words)

Steriking Packaging for Medical Devices serve as an enclosure for medical devices during steam sterilization that maintains the sterility of the enclosed medical devices until use of the medical devices with a combined weight of metal and plastics of 2.6 pounds or less. The recommended sterilization cycles are as follows:

Pre-vacuum steam at 132oC for 4 minutes; Drying time of 20 minutes

Pre-vacuum steam at 135oC for 3 minutes; Drying time of 16 minutes

The Steriking Packaging for medical devices consists of a paper backing (Bleached wood pulp, grammage 100 g/m2) with transparent plastic film laminate front (2 sheets of laminated plastic with a total grammage of 55 g/m2, 1 sheet of oriented polyester 12 microns thick, 1 sheet of coextruded polypropylene 40 microns thick. The plastic laminate is triple heat sealed to the backing paper. The open end of the pouch is to be selfsealed once a device is inserted. Self-sealable pouches are featured with adhesive strip allowing tight, impermeable closing of a pack. The closing flap is pre-folded to facilitate the closure. When closing the self-seal pouch the paper flap shall be folded along the pre-folded line. Flap should be pressed firmly against the laminate from the center working outwards to ensure a good, even seal.

Steriking Packaging for Medical Devices maintains the sterility of the enclosed devices for up to 12 months post Steam sterilization and before sterilization has a maximum shelflife of 5 years from the date of manufacture.

Steriking Packaging for Medical Devices Dimensional configurations (2 sizes 200mm x 800mm, 250mm x 875mm)

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K221016: Steriking Packaging for Medical Devices.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K221016

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026