510(k) Report

510(k) · Cleared

Cleared

Anatomic Bone Plate

K221088510(k) TraditionalCleared Jan 18, 2023280-day reviewClass II21 CFR 888.3030

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Double Medical Technology, Inc. · HRS Plate, Fixation, Bone

Cleared on Jan 18, 2023 as substantially equivalent to K130108 (Xiamen Double Engine Medical Material Co., Ltd., 2013) after a 280-day review. Its family tree reaches back 3 generations to 1998. 1 later device descends from it.

Decided
Jan 18, 2023
Review
280 days
Class
Class II
Product code
HRS
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K983495 (1998). 8 ancestors in all, the oldest K963192 (1996). 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2006: 1 other ancestor2005: 1 other ancestor2004: 1 other ancestor2001: 1 other ancestor1996: 1 other ancestor2024: 1 descendant clearedK983495 · Syntec-Taichung Non-Sterile Bone Plate and Screw Implants, Model#'S 222020-248120, 240050-240980, 241130-246620, 4240420 · Syntec Scientific Corp. · 1998K092889 · Syntec Osteo-Plate and Screw Fixation · Syntec Scientific Corp. · 2010K130108 · Double Engine Bone Plate and Screw Systems · Xiamen Double Engine Medical Material Co., Ltd. · 20131995200020052010201520202025
  1. Root · 3 generations backK983495 Syntec-Taichung Non-Sterile Bone Plate and Screw Implants, Model#'S…Syntec Scientific Corp. · 1998
  2. 2 generations backK092889 Syntec Osteo-Plate and Screw FixationSyntec Scientific Corp. · 2010
  3. 1 generation backK130108 Double Engine Bone Plate and Screw SystemsXiamen Double Engine Medical Material Co., Ltd. · 2013
  4. This deviceK221088 Anatomic Bone PlateDouble Medical Technology, Inc. · 2023
  5. Descendant · cites it directly · 0 of its ownK242348 Locking Screw,CoCrMoDouble Medical Technology, Inc. · 2024

Most influential descendants

Showing 1 of 1 · See all
  • K242348Locking Screw,CoCrMoDouble Medical Technology, Inc. · 2024 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K983495Syntec-Taichung Non-Sterile Bone Plate and Screw Implants, Model#'S…Syntec Scientific Corp.1998—
−2K092889Syntec Osteo-Plate and Screw FixationSyntec Scientific Corp.2010—
−1K130108Double Engine Bone Plate and Screw SystemsXiamen Double Engine Medical Material Co., Ltd.2013—
0 (this device)K221088Anatomic Bone PlateDouble Medical Technology, Inc.2023—
+1K242348Locking Screw,CoCrMoDouble Medical Technology, Inc.2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199610
200110
200410
200510
200610

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202410
FIG. 1 — Lineage of K221088, 1998–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HRS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HRS device

  1. #1 K222465 Tyber Medical Anatomical Plating Systemscore 27.5 · 16 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K130108Double Engine Bone Plate and Screw Systems
Summary page 4
…ulatory class II Classification panel Orthopedic 3. Predicate Device Legally marketed Predicate device: device(s) to which K130108 Double Engine Bone Plate and Bone Screw System equivalence is claimed Reason for 510(k) New device…
Xiamen Double Engine Medical Material Co., Ltd.2013—

Also cleared against K130108: 8 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K242348Locking Screw,CoCrMoDouble Medical Technology, Inc.20240

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 25 years and passes through 3 companies; a new generation was cleared every 9.7 years on median.
  • None of the 8 ancestors has a recall.
  • Of its descendants, K242348 (Double Medical Technology, Inc., 2024) has gone furthest, with 0 descendants of its own.
  • 8 other devices also cite its predicate K130108.

How does its category compare?

All HRS devices

HRS Plate, Fixation, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · HRS

54in 2025

2007: 352008: 352009: 472010: 492011: 432012: 592013: 562014: 762015: 562016: 442017: 572018: 402019: 462020: 482021: 402022: 472023: 402024: 542025: 542026 (partial year): 51
2007high 76 (2014) · low 35 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HRS

90in 2025

2007: 63 days median2008: 87 days median2009: 85 days median2010: 100 days median2011: 88 days median2012: 106 days median2013: 89 days median2014: 57 days median2015: 97 days median2016: 109 days median2017: 122 days median2018: 116 days median2019: 89 days median2020: 88 days median2021: 87 days median2022: 144 days median2023: 120 days median2024: 96 days median2025: 90 days median2026 (partial year): 82 days median
2007high 144 (2022) · low 57 (2014)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HRS

1in 2025

2007: 22008: 112009: 32010: 162011: 52012: 42013: 112015: 72016: 52017: 32018: 22019: 252020: 12021: 92022: 32023: 12025: 12026 (partial year): 3
2007high 25 (2019) · low 0 (2014)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HRS

2,306in 2025

2007: 3392008: 3112009: 4352010: 4912011: 7732012: 1,6632013: 2,6432014: 2,4132015: 3,0952016: 2,2762017: 2,2202018: 2,6632019: 3,3592020: 2,7902021: 2,4422022: 1,7002023: 2,0492024: 1,8492025: 2,306
2007high 3,359 (2019) · low 311 (2008)2025

MAUDE reports naming product code HRS, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200735632339
2008358711311
200947853435
20104910016491
201143885773
20125910641,663
20135689112,643
2014765702,413
2015569773,095
20164410952,276
20175712232,220
20184011622,663
20194689253,359
2020488812,790
2021408792,442
20224714431,700
20234012012,049
2024549601,849
2025549012,306
202651823—

What is it indicated for?

The Anatomic Bone Plates are intended for the internal fixation of fractures (VAL Distal Clavicle, VAL Proximal Humeral, VAL Distal Humeral, Distal Ulnar Locking, Distal Radial Locking, VAL Proximal Tibia, VAL Distal Tibia, VAL Distal Lateral Fibular, VAL Distal Femoral, Pelvic Bone Plate), fracture dislocations (VAL Proximal Humeral), osteotomies, and mal/non-unions (VAL Distal Clavicle, VAL Proximal Humeral, VAL Distal Humeral) of the clavicle, pelvis…

Read the full statement (155 words)

The Anatomic Bone Plates are intended for the internal fixation of fractures (VAL Distal Clavicle, VAL Proximal Humeral, VAL Distal Humeral, Distal Ulnar Locking, Distal Radial Locking, VAL Proximal Tibia, VAL Distal Tibia, VAL Distal Lateral Fibular, VAL Distal Femoral, Pelvic Bone Plate), fracture dislocations (VAL Proximal Humeral), osteotomies, and mal/non-unions (VAL Distal Clavicle, VAL Proximal Humeral, VAL Distal Humeral) of the clavicle, pelvis, and the upper (i.e., humerus, ulna and radius) and lower (i.e., femur, tibia, and fibula) extremities. Additional plates included in the system with specific indications as follows:

VAL (Variable Angle Locking) Distal Clavicle Plate is indicated for fractures of the shaft and lateral clavicle, malunions and non-unions ;

VAL Distal Humeral Plate is indicated for fractures (including supracondylar), and nonunions ;

VAL Distal Femoral Plate is indicated for distal femoral fractures (diaphyseal, supracondylar, and intra-articular);

Pelvic Bone Plate is indicated for pelvic fractures (e.g., acetabular , iliac wing, and symphysis pubis).

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K221088: Anatomic Bone Plate.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K221088

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026