510(k) Report

510(k) · Cleared

Cleared

BEL-GEN Cold Storage Solution

K221387510(k) TraditionalCleared Jun 14, 202232-day reviewClass II21 CFR 876.5880

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Institut Georges Lopez · KDL Set, Perfusion, Kidney, Disposable

Cleared on Jun 14, 2022 as substantially equivalent to K121618 (Waters Medical Systems, LLC, 2013) and 1 other predicate after a 32-day review. Its family tree reaches back 4 generations to 1996.

Decided
Jun 14, 2022
Review
32 days
Class
Class II
Product code
KDL
Recalls
None
Predicates
2

Its longest line of descent runs back 4 generations to K944866 (1996). 5 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 4 generations backK944866 Viaspan (Belzer UW - CSS)The Dupont Merck Pharmaceutical Co. · 1996 · Recalled
  2. 3 generations backK073693 CostorsolPreservation Solutions, Inc. · 2008 · Recalled
  3. 2 generations backK083453 CostorsolPreservation Solutions, Inc. · 2009
  4. 1 generation backK091245 CostorsolPreservation Solutions, Inc. · 2009
  5. This deviceK221387 BEL-GEN Cold Storage SolutionInstitut Georges Lopez · 2022
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K944866Viaspan (Belzer UW - CSS)The Dupont Merck Pharmaceutical Co.19961
−3K073693CostorsolPreservation Solutions, Inc.20082
−2K083453CostorsolPreservation Solutions, Inc.2009—
−1K091245CostorsolPreservation Solutions, Inc.2009—
0 (this device)K221387BEL-GEN Cold Storage SolutionInstitut Georges Lopez2022—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
201310
FIG. 1 — Lineage of K221387, 1996–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KDL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KDL device

  1. #1 K241239 OrganProtex HTK Solutionscore 9.9 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K121618Bel-Gen Cold Storage Solution
Summary page 4
…Class II Product Code: KDL, KDN III. Predicate Device Identification Primary predicate: BEL-GEN Cold Storage Solution – Waters Instruments, Inc. – K121618 Secondary predicate: CoStorSol® - Preservation Solution Inc. – K091245 IV. Device Description Institut Georges Lopez manufac…
Waters Medical Systems, LLC2013—
*K091245Costorsol
Summary page 4
…evice Identification Primary predicate: BEL-GEN Cold Storage Solution – Waters Instruments, Inc. – K121618 Secondary predicate: CoStorSol® - Preservation Solution Inc. – K091245 IV. Device Description Institut Georges Lopez manufactures the BEL-GEN Cold Storage Solution according to the solution pione…
Preservation Solutions, Inc.2009—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 26 years and passes through 3 companies; a new generation was cleared every 12.2 years on median.
  • 2 of the 5 ancestors have a recall of any class.

How does its category compare?

All KDL devices

KDL Set, Perfusion, Kidney, Disposable: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.

FDA decisions per year · KDL

1in 2025

2010: 12013: 22017: 12020: 12021: 12022: 22025: 1
2007high 2 (2013) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KDL

Too few KDL 510(k)s in any year since 2007 to give a median.

Recalls per year · KDL

1in 2016

2012: 12016: 1
2007high 1 (2012) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KDL

1in 2025

2007: 72009: 22011: 12012: 12016: 302017: 102019: 12021: 22025: 1
2007high 30 (2016) · low 0 (2008)2025

MAUDE reports naming product code KDL, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—07
20080—00
20090—02
20101—00
20110—01
20120—11
20132—00
20140—00
20150—00
20160—130
20171—010
20180—00
20190—01
20201—00
20211—02
20222—00
20230—00
20240—00
20251—01
20260—0—

What is it indicated for?

The BEL-GEN Cold Storage Solution is intended for the flushing and the hypothermic storage of kidney, liver and pancreas organs at the time of organ removal from the donor in preparation for storage, transportation and eventual transplantation into a recipient.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K221387: BEL-GEN Cold Storage Solution.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K221387

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026