510(k) Report

510(k) · Cleared

Cleared

OrganProtex HTK Solution

K241239510(k) TraditionalCleared Jan 24, 2025266-day reviewClass II21 CFR 876.5880

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bridge TO Life, Ltd. · KDL Set, Perfusion, Kidney, Disposable

Cleared on Jan 24, 2025 as substantially equivalent to K192408 (Dr. Franz Kohler Chemie GmbH, 2020) after a 266-day review. Its family tree reaches back 5 generations to 1996.

Decided
Jan 24, 2025
Review
266 days
Class
Class II
Product code
KDL
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to K944866 (1996). No later device cites it as a predicate yet.

  1. Root · 5 generations backK944866 Viaspan (Belzer UW - CSS)The Dupont Merck Pharmaceutical Co. · 1996 · Recalled
  2. 4 generations backK992209 CustodiolDr. Franz Kohler Chemie GmbH · 1999
  3. 3 generations backK020924 Custodiol HTK SolutionDr. Franz Kohler Chemie GmbH · 2003
  4. 2 generations backK043461 CustodiolDr. Franz Kohler Chemie GmbH · 2005
  5. 1 generation backK192408 Custodiol HTK SolutionDr. Franz Kohler Chemie GmbH · 2020 · Recalled
  6. This deviceK241239 OrganProtex HTK SolutionBridge TO Life, Ltd. · 2025
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K944866Viaspan (Belzer UW - CSS)The Dupont Merck Pharmaceutical Co.19961
−4K992209CustodiolDr. Franz Kohler Chemie GmbH1999—
−3K020924Custodiol HTK SolutionDr. Franz Kohler Chemie GmbH2003—
−2K043461CustodiolDr. Franz Kohler Chemie GmbH2005—
−1K192408Custodiol HTK SolutionDr. Franz Kohler Chemie GmbH20201
0 (this device)K241239OrganProtex HTK SolutionBridge TO Life, Ltd.2025—
FIG. 1 — Lineage of K241239, 1996–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KDL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KDL device

  1. #1 K221387 BEL-GEN Cold Storage Solutionscore 4.4 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K192408Custodiol HTK Solution
Summary page 5
…Company Device K Number Date Cleared Dr. Franz Kohler Chemie Custodiol® HTK Solution K192408 April 24, 2020 GmBH (Germany) 4.0 DEVICE DESCRIPTION OrganProtexTM HTK Solut…
Dr. Franz Kohler Chemie GmbH20201

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 29 years and passes through 3 companies; a new generation was cleared every 3.6 years on median.
  • 2 of the 5 ancestors have a recall of any class.

How does its category compare?

All KDL devices

KDL Set, Perfusion, Kidney, Disposable: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · KDL

1in 2025

2010: 12013: 22017: 12020: 12021: 12022: 22025: 1
2007high 2 (2013) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KDL

Too few KDL 510(k)s in any year since 2007 to give a median.

Recalls per year · KDL

1in 2016

2012: 12016: 1
2007high 1 (2012) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KDL

1in 2025

2007: 72009: 22011: 12012: 12016: 302017: 102019: 12021: 22025: 1
2007high 30 (2016) · low 0 (2008)2025

MAUDE reports naming product code KDL, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—07
20080—00
20090—02
20101—00
20110—01
20120—11
20132—00
20140—00
20150—00
20160—130
20171—010
20180—00
20190—01
20201—00
20211—02
20222—00
20230—00
20240—00
20251—01
20260—0—

What is it indicated for?

The OrganProtex™ HTK Solution is indicated for perfusion and flushing of donor kidneys, liver, pancreas and heart prior to removal from the donor or immediately after removal from the donor. The solution is left in the organ vasculature during hypothermic storage and transportation to the patient. OrganProtex™ HTK Solution is not indicated for continuous machine perfusion of donor organs.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K241239: OrganProtex HTK Solution.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K241239

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026