ClearedV-PRO maX 2 Low Temperature Sterilization System, V-PRO maX Low Temperature Sterilization System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Steris · MLR Sterilizer, Chemical
Cleared on Sep 9, 2022 as substantially equivalent to K190103 (STERIS Corporation, 2019) after a 56-day review. Its family tree reaches back 1 generation to 2019. 2 later devices descend from it.
- Decided
- Sep 9, 2022
- Review
- 56 days
- Class
- Class II
- Product code
- MLR
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K190103 (2019). 2 later devices descend from it, 1 citing it directly.
- Root · 1 generation backK190103 V-PRO maX 2 Low Temperature Sterilization System, V-PRO maX Low…STERIS Corporation · 2019
- This deviceK222093 V-PRO maX 2 Low Temperature Sterilization System, V-PRO maX Low…Steris · 2022
- Descendant · cites it directly · 1 of its ownK223476 V-PRO maX 2 Low Temperature Sterilization SystemSTERIS Corporation · 2023
- Descendant · 2 generations on · 0 of its ownK233065 V-PRO maX 2 Low Temperature Sterilization SystemSteris · 2023
Most influential descendants
Showing 2 of 2 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K190103 | V-PRO maX 2 Low Temperature Sterilization System, V-PRO maX Low Temperature… | STERIS Corporation | 2019 | — |
| 0 (this device) | K222093 | V-PRO maX 2 Low Temperature Sterilization System, V-PRO maX Low Temperature… | Steris | 2022 | — |
| +1 | K223476 | V-PRO maX 2 Low Temperature Sterilization System | STERIS Corporation | 2023 | — |
| +2 | K233065 | V-PRO maX 2 Low Temperature Sterilization System | Steris | 2023 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2023 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MLR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MLR device
- #1 K250802 STERRAD® 100NX Sterilizer with ALLClear™…score 14.0 · 7 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K190103 | V-PRO maX 2 Low Temperature Sterilization System, V-PRO maX Low Temperature…Summary page 6…The claimed primary predicate device is the V-PRO maX and maX 2 Low Temperature Sterilization Systems, cleared most recently under K190103. Table 5-1. A comparison between the proposed V-PRO maX Low Temperature Sterilization System to the predicate device… | 2019 |
What descends from it? (2)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K223476 | V-PRO maX 2 Low Temperature Sterilization System | 2023 | 1 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All MLR devicesMLR Sterilizer, Chemical: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.
FDA decisions per year · MLR
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · MLR
216in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MLR
1in 2017
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MLR
46in 2025
MAUDE reports naming product code MLR, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 5 | 272 |
| 2008 | 0 | — | 8 | 536 |
| 2009 | 1 | — | 2 | 433 |
| 2010 | 0 | — | 1 | 211 |
| 2011 | 6 | 214 | 2 | 34 |
| 2012 | 2 | — | 3 | 101 |
| 2013 | 1 | — | 9 | 541 |
| 2014 | 2 | — | 3 | 399 |
| 2015 | 1 | — | 0 | 412 |
| 2016 | 4 | 183 | 0 | 286 |
| 2017 | 2 | — | 1 | 279 |
| 2018 | 2 | — | 0 | 289 |
| 2019 | 4 | 90 | 0 | 222 |
| 2020 | 0 | — | 0 | 174 |
| 2021 | 2 | — | 0 | 202 |
| 2022 | 2 | — | 0 | 188 |
| 2023 | 5 | 222 | 0 | 140 |
| 2024 | 3 | 216 | 0 | 44 |
| 2025 | 1 | — | 0 | 46 |
| 2026 | 1 | — | 0 | — |
What is it indicated for?
The V-PRO maX Low Temperature Sterilization System using VAPROX HC Sterilant is intended for use in the terminal sterilization of properly prepared (cleaned, rinsed and dried) medical devices in Healthcare Facilities. The preprogrammed sterilization cycles operate at low pressure and temperature, suitable for processing medical devices without leaving toxic residues. Each Cycle can sterilize non-lumened instruments with diffusion-restricted spaces such…
Read the full statement (497 words)
The V-PRO maX Low Temperature Sterilization System using VAPROX HC Sterilant is intended for use in the terminal sterilization of properly prepared (cleaned, rinsed and dried) medical devices in Healthcare Facilities. The preprogrammed sterilization cycles operate at low pressure and temperature, suitable for processing medical devices without leaving toxic residues.
Each Cycle can sterilize non-lumened instruments with diffusion-restricted spaces such as the hinged portion of forceps and scissors.
The V-PRO maX Sterilizers’ Non Lumen Cycle can sterilize:
Non-lumened instruments including non-lumened general medical instruments, non-lumened rigid, semi-rigid and flexible endoscopes.
The validation studies were conducted using a validation load consisting of two instrument trays for a total weight of 50 Ibs (22.7 kg).
The V-PRO maX Sterilizer’s Flexible Cycle can sterilize:
Single or dual lumen surgical flexible endoscopes (such as those used in ENT, Urology and Surgical Care) and bronchoscopes in either of the two configurations:
1. Two flexible endoscopes with a light cord (if not integral to endoscope) and mat with no additional load. The flexible endoscopes may contain single or dual channel lumens that are > 1 mm internal diameter (ID) and < 1050 mm in length. The validation studies were conducted with two flexible endoscopes, each packaged into a tray with silicone mat and light cord (if not integral to endoscope).
2. One flexible endoscope with a light cord (if not integral to endoscope), endoscope accessories and mat, and additional instruments. The flexible endoscope may contain single or dual channel lumens that are > 1 mm ID and < 1050 mm in length.
Additional instruments may include non-lumened or lumened medical devices with the following configurations: Single, dual or triple channel stainless steel lumen that is > 0.48 mm ID and < 100 mm in length.
The validation studies were conducted with a flexible endoscope in a tray with endoscope accessories, silicone mat, light cord (if not integral to endoscope) and 5 stainless steel lumens. Also included in the load was a tray with additional instruments and silicone mat for a total weight of 24 1bs (11 kg).
The V-PRO maX Sterilizers’ Lumen Cycle can sterilize: Medical devices with the following configurations:
Single, dual or triple channeled stainless steel lumen that are:
>0.77 mm ID and < 527 mm in length
> 0.8 mm ID and < 542 mm in length
>0.48 mm ID and < 100 mm in length
Dead end lumen that is > 1.3 mm ID and < 73 mm in length
Rigid non-metallic lumen (such as those used in endoscope sheaths, take-apart forceps and trocars) that are:
>3 mm ID and < 298 mm in length
>4 mm ID and < 424 mm in length
Validation testing for all lumen sizes was conducted using a maximum of 20 lumens per load. Hospital loads should not exceed the maximum number of lumens validated by this testing. The validation studies were performed using a validation load consisting of two trays with silicone mats for a total weight of 19.65 Ibs (8.9 kg).
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K222093 · printed Nov 5, 2026
Cite this page
510(k) Report. “K222093: V-PRO maX 2 Low Temperature Sterilization System, V-PRO maX Low Temperature Sterilization System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K222093
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026