LVIS Corporation · OMB Automatic Event Detection Software For Full-Montage Electroencephalograph
Cleared on Jun 9, 2023 after a 298-day review. The FDA summary names no predicate by number.
- Decided
- Jun 9, 2023
- Review
- 298 days
- Class
- Class II
- Product code
- OMB
- Recalls
- None
- Predicates
- 0
The FDA summary names no predicate by number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in OMB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new OMB device
- #1 K240993 encevis (2.1)score 15.0 · 4 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
The FDA summary names no predicate by number.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All OMB devicesOMB Automatic Event Detection Software For Full-Montage Electroencephalograph: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.
FDA decisions per year · OMB
5in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · OMB
143in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · OMB
1in 2021
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · OMB
6in 2025
MAUDE reports naming product code OMB, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 1 | — | 0 | 0 |
| 2010 | 1 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 1 |
| 2012 | 1 | — | 0 | 0 |
| 2013 | 1 | — | 0 | 0 |
| 2014 | 2 | — | 0 | 2 |
| 2015 | 3 | 233 | 0 | 0 |
| 2016 | 0 | — | 0 | 0 |
| 2017 | 1 | — | 0 | 0 |
| 2018 | 3 | 108 | 0 | 0 |
| 2019 | 1 | — | 0 | 0 |
| 2020 | 1 | — | 0 | 0 |
| 2021 | 1 | — | 1 | 0 |
| 2022 | 1 | — | 0 | 1 |
| 2023 | 2 | — | 0 | 4 |
| 2024 | 5 | 201 | 0 | 21 |
| 2025 | 5 | 143 | 0 | 6 |
| 2026 | 1 | — | 0 | — |
What is it indicated for?
1. LVIS NeuroMatch Software is intended for the review, monitoring and analysis of electroencephalogram (EEG) recordings made by EEG devices using scalp electrodes and to aid neurologists in the assessment of EEG. The device is intended to be used by qualified medical practitioners who will exercise professional judgement in using the information. 2. LVIS NeuroMatch includes the calculation and display of a set of quantitative measures intended to…
Read the full statement (232 words)
1. LVIS NeuroMatch Software is intended for the review, monitoring and analysis of electroencephalogram (EEG) recordings made by EEG devices using scalp electrodes and to aid neurologists in the assessment of EEG. The device is intended to be used by qualified medical practitioners who will exercise professional judgement in using the information.
2. LVIS NeuroMatch includes the calculation and display of a set of quantitative measures intended to monitor and analyze EEG waveforms. These include Artifact Strength, Asymmetry Spectrogram, Autocorrelation Spectrogram, and Fast Fourier Transform (FFT) Spectrogram. These quantitative EEG measures should always be interpreted in conjunction with review of the original EEG waveforms.
3. LVIS NeuroMatch displays physiological signals such as electrocardiogram (ECG/EKG) if it is provided in the EEG recording.
4. The aEEG functionality included in LVIS NeuroMatch is intended to monitor the state of the brain.
5. LVIS NeuroMatch Artifact Reduction (AR) is intended to reduce muscle and eye movements in EEG signals from the International Standard 10-20 placement. AR does not remove the entire artifact signal and is not effective for other types of artifacts. AR may modify portions of waveforms representing cerebral activity. Waveforms must still be read by a qualified medical practitioner trained in recognizing artifacts, and any interpretation or diagnosis must be made with reference to the original waveforms.
6. This device does not provide any diagnostic conclusion about the patient's condition to the user.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K222450 · printed Nov 5, 2026
Cite this page
510(k) Report. “K222450: LVIS NeuroMatch.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K222450
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026