Xenco Medical InterAlign Cervical Interbody System

K223059510(k) TraditionalCleared Jun 7, 2023250-day reviewClass II21 CFR 888.3080

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Xenco Medical, LLC · OVE Intervertebral Fusion Device With Integrated Fixation, Cervical

Cleared on Jun 7, 2023 as substantially equivalent to K160313 (Xenco Medical, LLC, 2016) and 1 other predicate after a 250-day review. Its family tree reaches back 1 generation to 2014.

Decided
Jun 7, 2023
Review
250 days
Class
Class II
Product code
OVE
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K140786 (2014). 2 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2016: 1 other ancestorReference device: K112913 · Spotlight Access System · Johnson & Johnson · 2011K140786 · Xenco Medical Cervical Interbody System · Xenco Medical, LLC · 20142010201520202025
Other ancestors, by generation 1 generation back: 1 other ancestor K140786 · Xenco Medical Cervical Interbody System · Xenco Medical, LLC · 20140
  1. Root · 1 generation backK140786 Xenco Medical Cervical Interbody SystemXenco Medical, LLC · 2014
  2. This deviceK223059 Xenco Medical InterAlign Cervical Interbody SystemXenco Medical, LLC · 2023
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K140786Xenco Medical Cervical Interbody SystemXenco Medical, LLC2014—
0 (this device)K223059Xenco Medical InterAlign Cervical Interbody SystemXenco Medical, LLC2023—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
201610
FIG. 1 — Lineage of K223059, 2014–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OVE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OVE device

  1. #1 K241846 E3D™-C Interbody Systemscore 32.1 · 32 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K160313Xenco Medical Cervical Interbody System
Summary page 4
…fusion device (21 CFR 888.3080) Code – Regulatory Class: Class II Classification Product Code: OVE, ODP Primary Predicate K160313 Xenco Medical Cervical Interbody System Device Additional Predicate K140786 Xenco Medical Cervical Interbody System Device Refere…
Xenco Medical, LLC2016—
*K140786Xenco Medical Cervical Interbody System
Summary page 4
…s: Class II Classification Product Code: OVE, ODP Primary Predicate K160313 Xenco Medical Cervical Interbody System Device Additional Predicate K140786 Xenco Medical Cervical Interbody System Device Reference Device K112913 DePuy Spine, Inc. Spotlight Access System Device Desc…
Xenco Medical, LLC2014—
†K112913Spotlight Access SystemJohnson & Johnson2011—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • None of the 2 ancestors has a recall.

How does its category compare?

All OVE devices

OVE Intervertebral Fusion Device With Integrated Fixation, Cervical: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · OVE

10in 2025

2007: 12008: 42009: 12010: 42011: 82012: 72013: 52014: 112015: 122016: 152017: 92018: 72019: 72020: 132021: 102022: 102023: 162024: 62025: 102026 (partial year): 13
2007high 16 (2023) · low 1 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OVE

105in 2025

2008: 131 days median2010: 210 days median2011: 139 days median2012: 125 days median2013: 71 days median2014: 168 days median2015: 113 days median2016: 149 days median2017: 100 days median2018: 105 days median2019: 87 days median2020: 149 days median2021: 93 days median2022: 144 days median2023: 97 days median2024: 56 days median2025: 105 days median2026 (partial year): 66 days median
2007high 210 (2010) · low 56 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OVE

2in 2021

2013: 12014: 12015: 12016: 12017: 12021: 2
2007high 2 (2021) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · OVE

132in 2025

2010: 22011: 192012: 592013: 2502014: 1502015: 1732016: 1452017: 1342018: 2102019: 1692020: 1622021: 1862022: 2002023: 1482024: 1422025: 132
2007high 250 (2013) · low 0 (2007)2025

MAUDE reports naming product code OVE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
2008413100
20091—00
2010421002
20118139019
20127125059
20135711250
2014111681150
2015121131173
2016151491145
201791001134
201871050210
20197870169
2020131490162
202110932186
2022101440200
202316970148
20246560142
2025101050132
202613660—

What is it indicated for?

When used as an intervertebral fusion device with bone graft, cervical: Xenco Medical InterAlign Cervical Interbody System devices are intended for spinal fusion procedures at one level (C3-C7) in skeletally mature patients with degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies) of the cervical spine. Devices are to be implanted via an open, anterior approach…

Read the full statement (241 words)

When used as an intervertebral fusion device with bone graft, cervical:

Xenco Medical InterAlign Cervical Interbody System devices are intended for spinal fusion procedures at one level (C3-C7) in skeletally mature patients with degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies) of the cervical spine. Devices are to be implanted via an open, anterior approach and packed with autogenous bone. Patients should have had at least six weeks of non-operative treatment prior to surgical treatment with the device. The device is intended to be used with supplemental fixation (e.g. anterior plate system).

When used as an intervertebral fusion device w/ integrated fixation, cervical (interbody spacer w/ provided plate, bone screws, and locking cover):

Xenco Medical InterAlign Cervical Interbody System constructs are stand-alone anterior cervical interbody fusion devices intended for use as an adjunct to fusion at one level (C3-C7) in skeletally mature patients with degenerative disc disease (defined as discogenic neck pain with degeneration of the disc confirmed by history and radiographic studies). Patients should have received at least six weeks of non-operative treatment prior to treatment with the device. Xenco Medical InterAlign Cervical Interbody System constructs are to be packed with autogenous bone graft and implanted via an open, anterior approach. Xenco Medical InterAlign Cervical Interbody System constructs are intended to be used with the plate, bone screws, and locking cover provided and require no additional fixation.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K223059: Xenco Medical InterAlign Cervical Interbody System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K223059

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026