510(k) Report

510(k) · Cleared

Cleared

VX1+

K223516510(k) TraditionalCleared Jan 21, 202360-day reviewClass II21 CFR 870.1425

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Volta Medical · DQK Computer, Diagnostic, Programmable

Cleared on Jan 21, 2023 as substantially equivalent to K201298 (Volta Medical, 2020) after a 60-day review. Its family tree reaches back 9 generations to 2000. 4 later devices descend from it.

Decided
Jan 21, 2023
Review
60 days
Class
Class II
Product code
DQK
Recalls
None
Predicates
1

Its longest line of descent runs back 9 generations to K001437 (2000). 17 ancestors in all, the oldest K982415 (1998). 4 later devices descend from it, 2 citing it directly.

  1. Root · 9 generations backK001437 Ensite 3000 System, Model EE3000Endocardial Solutions, Inc. · 2000
  2. 5 generations between
  3. 3 generations backK090017 Carto 3 EP Navigation System, V1.0 and AccessoriesBiosense Webster, Inc. · 2009 · Recalled
  4. 2 generations backK093566 Carto XP EP Navigation System, Version 10Biosense Webster, Inc. · 2010
  5. 1 generation backK201298 VX1Volta Medical · 2020
  6. This deviceK223516 VX1+Volta Medical · 2023
  7. Descendant · cites it directly · 2 of its ownK232616 Volta AF-XplorerVolta Medical · 2023
  8. Descendant · 2 generations on · 1 of its ownK243812 Volta AF-XplorerVolta Medical · 2025
  9. Descendant · cites it directly · 0 of its ownK252429 Vektor Computational ECG Mapping System (vMap®)Vektor Medical, Inc. · 2025
  10. Descendant · 3 generations on · 0 of its ownK251518 Volta AF-Xplorer IIVolta Medical · 2025
Show all 9 generations
  1. Root · 9 generations backK001437 Ensite 3000 System, Model EE3000Endocardial Solutions, Inc. · 2000
  2. 8 generations backK012926 Modification to Ensite 3000 System, Model EE3000Endocardial Solutions, Inc. · 2001
  3. 7 generations backK030129 Modification to Ensite 3000 System, Model EE3000Endocardial Solutions, Inc. · 2003
  4. 6 generations backK042493 Ensite System, Model EE3000Endocardial Solutions, Inc. · 2004
  5. 5 generations backK060954 Modification to Ensite System, Model EE3000St. Jude Medical, Inc.-Endocardial Solutions · 2006
  6. 4 generations backK072202 Carto 3 Navigation System (Model:FG-5400-00), Carto 3 External…Biosense Webster, Inc. · 2007
  7. 3 generations backK090017 Carto 3 EP Navigation System, V1.0 and AccessoriesBiosense Webster, Inc. · 2009 · Recalled
  8. 2 generations backK093566 Carto XP EP Navigation System, Version 10Biosense Webster, Inc. · 2010
  9. 1 generation backK201298 VX1Volta Medical · 2020
  10. This deviceK223516 VX1+Volta Medical · 2023

Most influential descendants

Showing 4 of 4 · See all
  • K232616Volta AF-XplorerVolta Medical · 2023 · cites it directly2descendants
  • K243812Volta AF-XplorerVolta Medical · 2025 · 2 generations on1descendant
  • K252429Vektor Computational ECG Mapping System (vMap®)Vektor Medical, Inc. · 2025 · cites it directly0descendants
  • K251518Volta AF-Xplorer IIVolta Medical · 2025 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−9K001437Ensite 3000 System, Model EE3000Endocardial Solutions, Inc.2000—
−8K012926Modification to Ensite 3000 System, Model EE3000Endocardial Solutions, Inc.2001—
−7K030129Modification to Ensite 3000 System, Model EE3000Endocardial Solutions, Inc.2003—
−6K042493Ensite System, Model EE3000Endocardial Solutions, Inc.2004—
−5K060954Modification to Ensite System, Model EE3000St. Jude Medical, Inc.-Endocardial Solutions2006—
−4K072202Carto 3 Navigation System (Model:FG-5400-00), Carto 3 External Reference…Biosense Webster, Inc.2007—
−3K090017Carto 3 EP Navigation System, V1.0 and AccessoriesBiosense Webster, Inc.20094
−2K093566Carto XP EP Navigation System, Version 10Biosense Webster, Inc.2010—
−1K201298VX1Volta Medical2020—
0 (this device)K223516VX1+Volta Medical2023—
+1K232616Volta AF-XplorerVolta Medical2023—
+2K243812Volta AF-XplorerVolta Medical2025—
+1K252429Vektor Computational ECG Mapping System (vMap®)Vektor Medical, Inc.2025—
+3K251518Volta AF-Xplorer IIVolta Medical2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199810
200010
200110
200310
200510
200620
200710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202310
202530
FIG. 1 — Lineage of K223516, 2000–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DQK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQK device

  1. #1 K213682 HemoSphere Advanced Monitor, HemoSphere…score 26.7 · 28 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K201298VX1
Summary page 4
…stem Classification Name: Programmable Diagnostic Computer Regulatory Class: 21 C.F.R § 870.1425 Product Code: DQK Predicate Devices Volta Medical, VX1 (K201298) Device Description The VX1+ is a machine and deep learning based-algorithm designed to assist operators in the…
Volta Medical2020—

Also cleared against K201298: 4 other devices →

What descends from it? (4)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K232616Volta AF-XplorerVolta Medical20232
K252429Vektor Computational ECG Mapping System (vMap®)Vektor Medical, Inc.20250

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 23 years and passes through 4 companies; a new generation was cleared every 1.6 years on median.
  • 1 of the 17 ancestors has a recall of any class.
  • Of its descendants, K232616 (Volta Medical, 2023) has gone furthest, with 2 descendants of its own.
  • 4 other devices also cite its predicate K201298.

How does its category compare?

All DQK devices

DQK Computer, Diagnostic, Programmable: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · DQK

23so far in 2026, the most since 2007

2007: 132008: 42009: 122010: 92011: 122012: 72013: 132014: 92015: 72016: 152017: 72018: 142019: 152020: 162021: 162022: 192023: 212024: 132025: 222026 (partial year): 23
2007high 23 (2026) · low 4 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQK

95in 2025

2007: 83 days median2008: 70 days median2009: 93 days median2010: 64 days median2011: 69 days median2012: 74 days median2013: 68 days median2014: 90 days median2015: 125 days median2016: 190 days median2017: 146 days median2018: 150 days median2019: 113 days median2020: 123 days median2021: 132 days median2022: 136 days median2023: 133 days median2024: 100 days median2025: 95 days median2026 (partial year): 151 days median
2007high 190 (2016) · low 64 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQK

1in 2025

2007: 42008: 12009: 22010: 32011: 22012: 32013: 12014: 42015: 22017: 22018: 62019: 12020: 12021: 12022: 22023: 22024: 242025: 12026 (partial year): 2
2007high 24 (2024) · low 0 (2016)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DQK

433in 2025

2007: 182008: 342009: 402010: 492011: 552012: 1292013: 1802014: 1152015: 1312016: 3402017: 2522018: 2612019: 2182020: 2152021: 3512022: 3192023: 3402024: 5572025: 433
2007high 557 (2024) · low 18 (2007)2025

MAUDE reports naming product code DQK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071383418
2008470134
20091293240
2010964349
20111269255
20127743129
201313681180
20149904115
201571252131
2016151900340
201771462252
2018141506261
2019151131218
2020161231215
2021161321351
2022191362319
2023211332340
20241310024557
202522951433
2026231512—

What is it indicated for?

The VX1+ assists operators in the real-time manual or automatic annotation of 3D anatomical and electrical maps of human atria for the presence of multipolar intra-cardiac atrial electrograms exhibiting spatiotemporal dispersion during atrial fibrillation or atrial tachycardia.

The clinical significance of utilizing the VX1+ software to help identify areas with intra-cardiac atrial electrograms exhibiting spatiotemporal dispersion for catheter ablation of atrial arrhythmias, such as atrial fibrillation, has not been established by clinical investigations.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K223516: VX1+.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K223516

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026