510(k) Report

510(k) · Cleared

Cleared

VitalFlowTM Centrifugal Pump

K223898510(k) TraditionalCleared Aug 25, 2023240-day reviewClass II21 CFR 870.4100

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Michigan Critical Care Consultants, Inc. (D.B.A Mc3 Inc.) · QNR Blood Pump For Ecmo, Long-Term (> 6 Hours) Use

Cleared on Aug 25, 2023 as substantially equivalent to K202751 (Cardiacassist, Inc., 2021) after a 240-day review. Its family tree reaches back 1 generation to 2021.

Decided
Aug 25, 2023
Review
240 days
Class
Class II
Product code
QNR
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K202751 (2021). No later device cites it as a predicate yet.

  1. Root · 1 generation backK202751 TandemHeart Pump and Escort ControllerCardiacassist, Inc. · 2021
  2. This deviceK223898 VitalFlowTM Centrifugal PumpMichigan Critical Care Consultants, Inc. (D.B.A Mc3 Inc.) · 2023
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K202751TandemHeart Pump and Escort ControllerCardiacassist, Inc.2021—
0 (this device)K223898VitalFlowTM Centrifugal PumpMichigan Critical Care Consultants, Inc. (D.B.A Mc3 Inc.)2023—
FIG. 1 — Lineage of K223898, 2021–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QNR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QNR device

  1. #1 K234118 CentriMag™ Acute Circulatory Support Systemscore 9.1 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K202751TandemHeart Pump and Escort Controller
Summary page 4
…: 21 CFR 870.4100 Product Code: QNR Predicate: TandemHeart Pump (K202751) Reference Device 1: Affinity CP Centrifugal Blood Pump BBAP40…
Cardiacassist, Inc.2021—
†K111657Affinity CP Centrifugal Blood Pump with Balance BiosurfaceMedtronic, Inc.2011—
†K991864Rotaflow Centrifugal Pump SystemJostra Medizintechnik AG20002

Also cleared against K202751: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • 1 other device also cites its predicate K202751.

How does its category compare?

All QNR devices

QNR Blood Pump For Ecmo, Long-Term (> 6 Hours) Use: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · QNR

1in 2025

2021: 12022: 22023: 22024: 22025: 1
2007high 2 (2022) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QNR

Too few QNR 510(k)s in any year since 2007 to give a median.

Recalls per year · QNR

1in 2025

2025: 1
2007high 1 (2025) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · QNR

187in 2025

2021: 12023: 52024: 1352025: 187
2007high 187 (2025) · low 0 (2007)2025

MAUDE reports naming product code QNR, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20190—00
20200—00
20211—01
20222—00
20232—05
20242—0135
20251—1187
20260—0—

What is it indicated for?

The VitalFlow™ Centrifugal Pump is intended to pump blood through the extracorporeal circuit for circulatory support up to 48 hours, in adult patients with acute respiratory failure or acute cardiopulmonary failure, where other available treatment options have failed, and continued clinical deterioration is expected or the risk of death is imminent.

The VitalFlow™ Centrifugal Pump is driven by the VitalFlow™ Console and Drive Motor, or the Emergency Handcrank.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K223898: VitalFlowTM Centrifugal Pump.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K223898

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026