510(k) · Cleared
ClearedPerforated Baskets
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Richard Wolf Medical Instruments Corporation · KCT Sterilization Wrap Containers, Trays, Cassettes & Other Accessories
Cleared on Jun 3, 2024 as substantially equivalent to K203198 (Karl Storz Endoscopy America, Inc., 2021) after a 396-day review. Its family tree reaches back 5 generations to 1984.
- Decided
- Jun 3, 2024
- Review
- 396 days
- Class
- Class II
- Product code
- KCT
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 5 generations to K844002 (1984). 7 ancestors in all. No later device cites it as a predicate yet.
- Root · 5 generations backK844002 HU-Friedy Ims Cassette SystemHu-Friedy Mfg. Co., Inc. · 1984
- 4 generations backK980065 C/T Med-Systems Cassette SystemC/T Med System, Ltd. · 1998
- 3 generations backK990761 Tuttnauer Mini Container Cassette, Tuttnauer Standard Case CassetteTuttnauer U.S.A Co, Ltd. · 1999
- 2 generations backK012105 Polyvac Surgical Instrument Delivery SystemSymmetry Medical, Inc. · 2002
- 1 generation backK203198 KARL STORZ Metal Sterilization TraysKarl Storz Endoscopy America, Inc. · 2021 · Recalled
- This deviceK231291 Perforated BasketsRichard Wolf Medical Instruments Corporation · 2024
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −5 | K844002 | HU-Friedy Ims Cassette System | Hu-Friedy Mfg. Co., Inc. | 1984 | — |
| −4 | K980065 | C/T Med-Systems Cassette System | C/T Med System, Ltd. | 1998 | — |
| −3 | K990761 | Tuttnauer Mini Container Cassette, Tuttnauer Standard Case Cassette | Tuttnauer U.S.A Co, Ltd. | 1999 | — |
| −2 | K012105 | Polyvac Surgical Instrument Delivery System | Symmetry Medical, Inc. | 2002 | — |
| −1 | K203198 | KARL STORZ Metal Sterilization Trays | Karl Storz Endoscopy America, Inc. | 2021 | 1 |
| 0 (this device) | K231291 | Perforated Baskets | Richard Wolf Medical Instruments Corporation | 2024 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1994 | 1 | 0 |
| 1997 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KCT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KCT device
- #1 K214041 Aesculap AICON Containerscore 18.1 · 6 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K203198 | KARL STORZ Metal Sterilization TraysSummary page 7…1 K231291 510(k) Summary 2. Predicate Device Name of Predicate Device: KARL STORZ Metal Sterilization Trays 510(k) Number: K203198 Regulatory Class: II Product Code: KCT Manufacturer: Karl Storz Endoscopy America Inc 3. Device Descrip… | 2021 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 40 years and passes through 6 companies; a new generation was cleared every 3.1 years on median.
- 1 of the 7 ancestors has a recall of any class.
How does its category compare?
All KCT devicesKCT Sterilization Wrap Containers, Trays, Cassettes & Other Accessories: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.
FDA decisions per year · KCT
11in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · KCT
205in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · KCT
17in 2022
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · KCT
50in 2025
MAUDE reports naming product code KCT, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 3 | 199 | 0 | 2 |
| 2008 | 6 | 182 | 0 | 8 |
| 2009 | 6 | 89 | 0 | 5 |
| 2010 | 12 | 202 | 1 | 3 |
| 2011 | 6 | 117 | 2 | 3 |
| 2012 | 10 | 236 | 0 | 2 |
| 2013 | 8 | 131 | 1 | 6 |
| 2014 | 11 | 169 | 1 | 5 |
| 2015 | 15 | 151 | 0 | 6 |
| 2016 | 12 | 182 | 3 | 16 |
| 2017 | 10 | 211 | 1 | 3 |
| 2018 | 15 | 192 | 0 | 22 |
| 2019 | 18 | 187 | 0 | 15 |
| 2020 | 14 | 134 | 0 | 66 |
| 2021 | 18 | 185 | 1 | 26 |
| 2022 | 11 | 137 | 17 | 8 |
| 2023 | 10 | 94 | 0 | 30 |
| 2024 | 8 | 106 | 0 | 18 |
| 2025 | 11 | 205 | 0 | 50 |
| 2026 | 9 | 122 | 0 | — |
What is it indicated for?
The products are used to store medical devices before, during, and after sterilization. The products are intended to enable sterilization of the enclosed medical devices but are not intended to maintain sterility on their own; instead, they are used in conjunction with an FDA-approved sterilization wrap that is legally available on the market. The products have no medical indications. Sterilization cycle times are as follow: Exposure time: 3 min…
Read the full statement (321 words)
The products are used to store medical devices before, during, and after sterilization.
The products are intended to enable sterilization of the enclosed medical devices but are not intended to maintain sterility on their own; instead, they are used in conjunction with an FDA-approved sterilization wrap that is legally available on the market.
The products have no medical indications. Sterilization cycle times are as follow: Exposure time: 3 min
Temperature: 132 °C Drying time: 20 min
The maximum validated load weight for all devices listed below is 4.5 kg (approx. 9.92 lbs).
All measurements are in millimeter and are coded as follows [WidthxHeightxLength].
UNIVERSAL PERFORATED BASKET 1 (33001); 732x117x282)
UNIVERSAL PERFORATED BASKET 2 (33002); (743x200x282)
UNIVERSAL PERFORATED BASKET 3 (33003); (538x117x250)
UNIVERSAL PERFORATED BASKET 4 (33004); (538x117x250)
UNIVERSAL PERFORATED BASKET 5 (33005); (549x200x250)
PERFORATED BASKET FOR SMALL PARTS (33006); (128x40x121)
PERF. BASKET – KNEE ARTHROSC. BASIC SET (33007); (549x150x250)
PERF. BASKET – KNEE ARTHROSC. ACL/PCL 1 (33008); (549x150x250)
PERF. BASKET – KNEE ARTHROSC. ACL/PCL 2 (33009); (549x150x250)
PERF. BASKET FOR KNEE ARTHROSC. PREP TAB (33010); (549x150x250)
PERF. BASKET FOR VERTEBRIS LUMBAR (33011); (549x150x250)
PERF. BASKET FOR SHOULDER ARTHROSCOPY (33012); (538x117x250)
PERF. BASKET FOR VERTEBRIS FORAMINOTOMY (33013); (525x65x255)
PERF. BASKET FOR VERTEBRIS STENOSIS (33015); (549x150x250)
PERFORATED BASKET FOR CAMERA HEAD (38002); (448x73x200)
PERFORATED BASKET, UPPER URINARY TRACT 1 (38003); (635x75x132)
PERF. BASKET FOR CYSTOSCOPE/TELESCOPE (38004); (467x75x132)
PERFORATED BASKET FOR DISCOSCOPE (38005); (467x75x132)
PERFORATED BASKET FOR HYSTEROSCOPE 1 (38006); (467x75x132)
PERF. BASKET FOR VIDEO MEDIASTINOSCOPE (38007); (256x85x250)
PERFORATED BASKET FOR TELESCOPE (38008); (467x75x132)
PERFORATED BASKET FOR HYSTEROSCOPE 2 (38009); (467x90x132)
PERFORATED BASKET FOR STEREO TELESCOPE (38010); (477x139x196)
PERFORATED BASKET FOR NEPHROSCOPE (38011); (467x75x172)
PERFORATED BASKET FOR MORCESCOPE (38012); (467x75x172)
PERFORATED BASKET FOR CYSTO-URETHROSCOPE (38013); (451x64x80)
PERFORATED BASKET FOR 3D TELESCOPE (38014); (583x80x200)
PERF. BASKET FOR STANDARD TELESCOPE 1 (38015); (297x54x59)
PERF. BASKET FOR STANDARD TELESCOPE 2 (38016); (481x54x59)
PERF. BASKET FOR STANDARD TELESCOPE 3 (38017); (619x54x59)
PERFORATED BASKET FOR PAIN THERAPY (33014); (525x95x255)
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K231291 · printed Nov 5, 2026
Cite this page
510(k) Report. “K231291: Perforated Baskets.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K231291
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026