Beta Bionics, Inc. · QFG Alternate Controller Enabled Insulin Infusion Pump

Cleared on Jun 21, 2023 as substantially equivalent to K223846 (Beta Bionics, Inc., 2023) after a 29-day review. Its family tree reaches back 3 generations to 2019. 1 of the 6 devices in its family, counting itself, has a Class I recall. 2 later devices descend from it. It has been recalled once.

Decided
Jun 21, 2023
Review
29 days
Class
Class II
Product code
QFG
Recalls
1
Predicates
1

Its longest line of descent runs back 3 generations to DEN180058 (2019). 2 later devices descend from it, 1 citing it directly. 1 of the 6 devices in this family, counting this one, has a Class I recall.

Descendants, by year cleared 2025: 1 descendant cleared2026: 1 descendant clearedDEN180058 · t:slim X2 insulin pump with interoperable technology · Tandem Diabetes Care, Inc. · 2019K201214 · t:slim X2 Insulin Pump with Interoperable Technology · Tandem Diabetes Care, Inc. · 2020 · Class I recallK223846 · iLet® ACE Pump · Beta Bionics, Inc. · 2023201620182020202220242026
  1. Root · 3 generations backDEN180058 t:slim X2 insulin pump with interoperable technologyTandem Diabetes Care, Inc. · 2019
  2. 2 generations backK201214 t:slim X2 Insulin Pump with Interoperable TechnologyTandem Diabetes Care, Inc. · 2020 · Recalled (Class I)
  3. 1 generation backK223846 iLet® ACE PumpBeta Bionics, Inc. · 2023
  4. This deviceK231485 iLet® ACE PumpBeta Bionics, Inc. · 2023
  5. Descendant · cites it directly · 1 of its ownK252770 iLet ACE PumpBeta Bionics, Inc. · 2025 · Recalled
  6. Descendant · 2 generations on · 0 of its ownK253976 iLet ACE PumpBeta Bionics, Inc. · 2026

Class I recalls in this family

Most influential descendants

Showing 2 of 2 · See all
  • K252770iLet ACE PumpBeta Bionics, Inc. · 2025 · cites it directly1descendant
  • K253976iLet ACE PumpBeta Bionics, Inc. · 2026 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3DEN180058t:slim X2 insulin pump with interoperable technologyTandem Diabetes Care, Inc.2019—
−2K201214t:slim X2 Insulin Pump with Interoperable TechnologyTandem Diabetes Care, Inc.2020Class I
−1K223846iLet® ACE PumpBeta Bionics, Inc.2023—
0 (this device)K231485iLet® ACE PumpBeta Bionics, Inc.2023—
+1K252770iLet ACE PumpBeta Bionics, Inc.20252
+2K253976iLet ACE PumpBeta Bionics, Inc.2026—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202510
202610
FIG. 1 — Lineage of K231485, 2019–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QFG device

  1. #1 K251032 MiniMed 780G insulin pumpscore 19.6 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K223846iLet® ACE Pump
Summary page 4
…ion pump Regulation Number, Device Class and Pro Code: 21CFR 880.5730, Class II, QFG Predicate Device: iLet® ACE Pump (Beta Bionics, Inc., K223846) Purpose of Special 510(k) Notification: The User Guide and Quick Reference Guide are being updated to indicate that the iLet bi…
Beta Bionics, Inc.2023—

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K252770iLet ACE PumpBeta Bionics, Inc.20251

Has anything in its family been recalled? (1 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Aug 13, 2025Class IIZ-1809-2026Software designit was found that in versions 1.3.7, 1.4.2, and 1.4.3, the Lock Screen and Limited Access Passcode Screen on the iLet graphical user interface (GUI) include certain icons displayed in the status bar that are active, thereby allowing the…

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K201214t:slim X2 Insulin Pump with Interoperable TechnologyTandem Diabetes Care, Inc. · 2020 · 2 generations back · ◆ on the line of descent in FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 4 years and passes through 2 companies; a new generation was cleared every 1.3 years on median.
  • 1 of the 3 ancestors has a recall of any class; 1 has a Class I recall.
  • Of its descendants, K252770 (Beta Bionics, Inc., 2025) has gone furthest, with 1 descendant of its own.

How does its category compare?

All QFG devices

QFG Alternate Controller Enabled Insulin Infusion Pump: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · QFG

5in 2025

2019: 22020: 12022: 22023: 92024: 52025: 52026 (partial year): 6
2007high 9 (2023) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QFG

44in 2025

2023: 150 days median2024: 89 days median2025: 44 days median2026 (partial year): 103 days median
2007high 150 (2023) · low 44 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · QFG

8so far in 2026, the most since 2007

2022: 12023: 1, 1 Class I2025: 3, 1 Class I2026 (partial year): 8, 1 Class I
2007high 8 (2026) · low 0 (2007)2026

Class I (3 since 2007) Class II/III not classified

Adverse event reports per year · QFG

324,360in 2025

2020: 30,5222021: 74,7012022: 129,1192023: 188,0142024: 273,1802025: 324,360
2007high 324,360 (2025) · low 0 (2007)2025

MAUDE reports naming product code QFG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20192—00
20201—030,522
20210—074,701
20222—1129,119
202391501 (1)188,014
20245890273,180
20255443 (1)324,360
202661038 (1)—

What is it indicated for?

The iLet ACE Pump is an alternate controller enabled (ACE) pump intended to deliver insulin under the skin based on input from an integrated continuous glucose monitor (iCGM) and an interoperable automated glycemic controller (iAGC), in people 6 years of age or older with diabetes mellitus. The iLet ACE Pump is intended for single-person use; it is not to be shared.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K231485: iLet® ACE Pump.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K231485

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026