510(k) Report

510(k) · Cleared

Cleared

NITINEX Memory Compression Staple

K231493510(k) TraditionalCleared Aug 11, 202380-day reviewClass II21 CFR 888.3030

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Vilex, LLC · JDR Staple, Fixation, Bone

Cleared on Aug 11, 2023 as substantially equivalent to K112837 (Vilex, Inc., 2012) after an 80-day review. Its family tree reaches back 4 generations to 1990.

Decided
Aug 11, 2023
Review
80 days
Class
Class II
Product code
JDR
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K902307 (1990). 5 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 4 generations backK902307 Shaw II Hemostatic Surgery SystemHemostatic Surgery Corp. · 1990 · Recalled
  2. 3 generations backK993714 Memograph Staple, Warm SystemBiomedical Ent., Inc. · 2000
  3. 2 generations backK070031 Memometal Memory StaplesMemometal Technologies · 2007
  4. 1 generation backK112837 Vilex EZ-Staple (Memory Bone Fixation Staple)Vilex, Inc. · 2012
  5. This deviceK231493 NITINEX Memory Compression StapleVilex, LLC · 2023
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K902307Shaw II Hemostatic Surgery SystemHemostatic Surgery Corp.19902
−3K993714Memograph Staple, Warm SystemBiomedical Ent., Inc.2000—
−2K070031Memometal Memory StaplesMemometal Technologies2007—
−1K112837Vilex EZ-Staple (Memory Bone Fixation Staple)Vilex, Inc.2012—
0 (this device)K231493NITINEX Memory Compression StapleVilex, LLC2023—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199710
FIG. 1 — Lineage of K231493, 1990–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JDR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JDR device

  1. #1 K243658 TMC Compression Implant Systemscore 16.7 · 18 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K112837Vilex EZ-Staple (Memory Bone Fixation Staple)
Summary page 4
…tiple component metallic bone fixation appliances and accessories Device Regulation Panel Orthopedic Predicate Device K112837, Vilex eZ-Staple Superelastic Bone Fixation Staple Device Description: The NITINEX Memory Compres…
Vilex, Inc.2012—

Also cleared against K112837: 3 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 33 years and passes through 5 companies; a new generation was cleared every 9.5 years on median.
  • 1 of the 5 ancestors has a recall of any class.
  • 3 other devices also cite its predicate K112837.

How does its category compare?

All JDR devices

JDR Staple, Fixation, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · JDR

3in 2025

2007: 82008: 52010: 22011: 12012: 12013: 92014: 112015: 72016: 62017: 92018: 82019: 52020: 42021: 32022: 52023: 92024: 42025: 32026 (partial year): 2
2007high 11 (2014) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JDR

65in 2025

2007: 70 days median2008: 89 days median2013: 137 days median2014: 97 days median2015: 111 days median2016: 101 days median2017: 172 days median2018: 107 days median2019: 149 days median2020: 161 days median2021: 62 days median2022: 107 days median2023: 72 days median2024: 29 days median2025: 65 days median
2007high 172 (2017) · low 29 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JDR

11in 2022

2008: 12015: 12018: 12020: 12022: 112026 (partial year): 2
2007high 11 (2022) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JDR

314in 2025

2007: 32008: 142009: 102010: 352011: 622012: 342013: 272014: 492015: 482016: 762017: 1162018: 2392019: 2422020: 2342021: 2102022: 2022023: 1752024: 2062025: 314
2007high 314 (2025) · low 3 (2007)2025

MAUDE reports naming product code JDR, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200787003
2008589114
20090—010
20102—035
20111—062
20121—034
20139137027
20141197049
20157111148
20166101076
201791720116
201881071239
201951490242
202041611234
20213620210
2022510711202
20239720175
20244290206
20253650314
20262—2—

What is it indicated for?

The NITINEX Memory Compression Staple is intended for hand and foot bone fragments osteotomy fixation and joint arthrodesis.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K231493: NITINEX Memory Compression Staple.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K231493

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026