510(k) Report

510(k) · Cleared

Cleared

EVOLVE Nitric Oxide Delivery System

K240410510(k) SpecialCleared May 28, 2024106-day reviewClass II21 CFR 868.5165

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Malinckrodt Manufacturing, LLC · MRN Apparatus, Nitric Oxide Delivery

Cleared on May 28, 2024 as substantially equivalent to K222930 (Mallinckrodt Manufacturing, LLC, 2023) after a 106-day review. Its family tree reaches back 1 generation to 2023. 1 later device descends from it.

Decided
May 28, 2024
Review
106 days
Class
Class II
Product code
MRN
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K222930 (2023). 1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2025: 1 descendant clearedK222930 · Evolve Nitric Oxide Delivery System · Mallinckrodt Manufacturing, LLC · 20232020202220242026
Descendants, by generation 1 generation forward: 1 descendant K222930 · Evolve Nitric Oxide Delivery System · Mallinckrodt Manufacturing, LLC · 20230
  1. Root · 1 generation backK222930 Evolve Nitric Oxide Delivery SystemMallinckrodt Manufacturing, LLC · 2023
  2. This deviceK240410 EVOLVE Nitric Oxide Delivery SystemMalinckrodt Manufacturing, LLC · 2024
  3. Descendant · cites it directly · 0 of its ownK242578 EVOLVE Nitric Oxide Delivery SystemMallinckrodt Manufacturing, LLC · 2025

Most influential descendants

Showing 1 of 1 · See all
  • K242578EVOLVE Nitric Oxide Delivery SystemMallinckrodt Manufacturing, LLC · 2025 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K222930Evolve Nitric Oxide Delivery SystemMallinckrodt Manufacturing, LLC2023—
0 (this device)K240410EVOLVE Nitric Oxide Delivery SystemMalinckrodt Manufacturing, LLC2024—
+1K242578EVOLVE Nitric Oxide Delivery SystemMallinckrodt Manufacturing, LLC2025—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202510
FIG. 1 — Lineage of K240410, 2023–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MRN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MRN device

  1. #1 K242374 ULSPIRA TS™ Nitric Oxide Therapy Systemscore 12.6 · 14 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K222930Evolve Nitric Oxide Delivery System
Summary page 6
…1 Mallinckrodt 510(k) Premarket Notification EVOLVE Nitic Oxide Delivery System Predicate Device(s) K222930 Description of Device The EVOLVE Nitric Oxide (NO) Delivery System (DS) is used…
Mallinckrodt Manufacturing, LLC2023—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K242578EVOLVE Nitric Oxide Delivery SystemMallinckrodt Manufacturing, LLC20250

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K242578 (Mallinckrodt Manufacturing, LLC, 2025) has gone furthest, with 0 descendants of its own.

How does its category compare?

All MRN devices

MRN Apparatus, Nitric Oxide Delivery: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · MRN

2in 2025

2007: 22008: 22009: 12010: 22011: 22012: 32013: 22015: 12018: 12020: 32022: 12023: 42024: 22025: 2
2007high 4 (2023) · low 0 (2014)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MRN

566in 2023

2012: 117 days median2020: 84 days median2023: 566 days median
2007high 566 (2023) · low 84 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MRN

2in 2025

2010: 22014: 12023: 12025: 2, 2 Class I2026 (partial year): 2
2007high 2 (2010) · low 0 (2007)2026

Class I (2 since 2007) Class II/III not classified

Adverse event reports per year · MRN

155in 2025

2007: 32008: 92009: 102010: 1552011: 552012: 242013: 322014: 792015: 1562016: 942017: 1062018: 1382019: 1442020: 1992021: 2212022: 1152023: 992024: 1382025: 155
2007high 221 (2021) · low 3 (2007)2025

MAUDE reports naming product code MRN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—03
20082—09
20091—010
20102—2155
20112—055
20123117024
20132—032
20140—179
20151—0156
20160—094
20170—0106
20181—0138
20190—0144
20203840199
20210—0221
20221—0115
20234566199
20242—0138
20252—2 (2)155
20260—2—

What is it indicated for?

The Evolve DS (delivery system) delivers INOMAX@ (nitric oxide for inhalation) therapy gas into the inspiratory limb of the patient breathing circuit in a way that provides a constant concentration of nitric oxide (NO), as set by the user, to the patient throughout the inspired breath. It uses a specially designed Injector Module, which enables tracking of the gas delivery system waveforms and the delivery of a synchronized and proportional dose of NO.…

Read the full statement (290 words)

The Evolve DS (delivery system) delivers INOMAX@ (nitric oxide for inhalation) therapy gas into the inspiratory limb of the patient breathing circuit in a way that provides a constant concentration of nitric oxide (NO), as set by the user, to the patient throughout the inspired breath. It uses a specially designed Injector Module, which enables tracking of the gas delivery system waveforms and the delivery of a synchronized and proportional dose of NO. It may be used with ventilators and respiratory care devices for which the Evolve DS has been validated. The Evolve DS provides continuous integrated monitoring of inspired N02 and NO with a comprehensive alarm system. The Evolve DS also provides monitoring and alarms for the drug delivery system.

The Evolve DS incorporates a battery that provides up to 4 hours of uninterrupted NO delivery in the absence of external power. The Evolve DS also incorporates an integrated electronic blender that functions as a backup delivery device to provide an adjustable INOmax dose with user supplied oxygen to a manual resuscitator or gas delivery system. The electronic blender incorporates a separate control and delivery pathway that serves as a redundant mechanism for nitric oxide delivery in the event of a main system fault.

The Evolve DS must only be used in accordance with the indications, contraindications, warnings and precautions described in the nitric oxide drug packaging inserts and labeling and is indicated for use in term and near-term (>34weeks gestation) neonates with hypoxic respiratory failure associated with clinical or echocardiographic evidence of pulmonary hypertension. The Evolve DS is indicated for a maximum of 14 days use. The primary targeted clinical setting is the Neonatal Intensive Care Unit (NICU), and secondary targeted clinical setting is the transport of neonates.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K240410: EVOLVE Nitric Oxide Delivery System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K240410

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026