510(k) Report

510(k) · Cleared

Cleared

BD Vacutainer® Citrate Blood Collection Tubes

K240455510(k) TraditionalCleared Oct 31, 2024259-day reviewClass II21 CFR 862.1675

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Becton, Dickinson and Company · GIM Tubes, Vacuum Sample, With Anticoagulant

Cleared on Oct 31, 2024 as substantially equivalent to K013971 (Becton, Dickinson & CO, 2002) after a 259-day review. Its family tree reaches back 1 generation to 2002.

Decided
Oct 31, 2024
Review
259 days
Class
Class II
Product code
GIM
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K013971 (2002). No later device cites it as a predicate yet.

K013971 · BD Vacutainer Safety Coagulation Tube · Becton, Dickinson & CO · 2002 · recalled200020052010201520202025
  1. Root · 1 generation backK013971 BD Vacutainer Safety Coagulation TubeBecton, Dickinson & CO · 2002 · Recalled
  2. This deviceK240455 BD Vacutainer® Citrate Blood Collection TubesBecton, Dickinson and Company · 2024
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K013971BD Vacutainer Safety Coagulation TubeBecton, Dickinson & CO20025
0 (this device)K240455BD Vacutainer® Citrate Blood Collection TubesBecton, Dickinson and Company2024—
FIG. 1 — Lineage of K240455, 2002–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GIM? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GIM device

  1. #1 K230493 BD MiniDraw Capillary Blood Collection System…score 6.7 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K013971BD Vacutainer Safety Coagulation Tube
Summary page 6
…Anticoagulant Classification Regulation: 21 CFR § 862.1675 Regulatory Class: Class II Product Code: GIM 1.9 Predicate Device BD Vacutainer Safety Coagulation Tube (K013971) 1.10 Device Establishment Becton, Dickinson and Company 1.11 Registration Number: 2243072 1.12 Performance Standar…
Becton, Dickinson & CO20025

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has a recall.

How does its category compare?

All GIM devices

GIM Tubes, Vacuum Sample, With Anticoagulant: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · GIM

1in 2024

2008: 12017: 12023: 22024: 1
2007high 2 (2023) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GIM

Too few GIM 510(k)s in any year since 2007 to give a median.

Recalls per year · GIM

1in 2025

2012: 12025: 1
2007high 1 (2012) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GIM

641in 2025

2009: 12010: 12011: 12012: 32016: 22017: 122018: 2762019: 1452020: 1472021: 552022: 422023: 332024: 3162025: 641
2007high 641 (2025) · low 0 (2007)2025

MAUDE reports naming product code GIM, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20081—00
20090—01
20100—01
20110—01
20120—13
20130—00
20140—00
20150—00
20160—02
20171—012
20180—0276
20190—0145
20200—0147
20210—055
20220—042
20232—033
20241—0316
20250—1641
20260—0—

What is it indicated for?

The BD Vacutainer® Citrate Blood Collection Tube (0.109M buffered sodium citrate) is a sterile, single use tube used for the collection, containment, transport, and centrifugation of venous blood specimens to obtain plasma for in vitro diagnostic testing. It is used in settings where a venous blood sample is collected by a trained healthcare worker. The BD Vacutainer® Citrate Blood Collection Tube is used for clinical laboratory testing in coagulation.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K240455: BD Vacutainer® Citrate Blood Collection Tubes.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K240455

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026