510(k) Report

510(k) · Cleared

Cleared

Cleerly LABS (v2.0)

K242338510(k) SpecialCleared Mar 7, 2025212-day reviewClass II21 CFR 892.2050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Cleerly, Inc. · QIH Automated Radiological Image Processing Software

Cleared on Mar 7, 2025 as substantially equivalent to K202280 (Cleerly, Inc., 2020) after a 212-day review. Its family tree reaches back 13 generations to 1991. 2 later devices descend from it.

Decided
Mar 7, 2025
Review
212 days
Class
Class II
Product code
QIH
Recalls
None
Predicates
1

Its longest line of descent runs back 13 generations to K913770 (1991). 70 ancestors in all, the oldest K871859 (1987). 2 later devices descend from it, 2 citing it directly.

Other ancestors, by generationDescendants, by generation 4 generations back: 2 other ancestors5 generations back: 10 other ancestors6 generations back: 14 other ancestors7 generations back: 10 other ancestors8 generations back: 8 other ancestors9 generations back: 6 other ancestors10 generations back: 3 other ancestors11 generations back: 3 other ancestors12 generations back: 1 other ancestor 1 generation forward: 2 descendants K202280 · Cleerly Labs v2.0 · Cleerly, Inc. · 2020K190868 · Cleerly Labs · Cleerly, Inc. · 2019K122429 · Vessel Analysis and Autoplaque for Ors Visual · Object Research Systems (Ors), Inc. · 2012K071331 · Vitrea Version 4.0 · Vital Images, Inc. · 2007 · recalledK061624 · Vitrea, Version 3.9 · Vital Images, Inc. · 2006 · recalledK052632 · VITREA2 Version 3.8 Medical Image Processing Software · Vital Images, Inc. · 2005 · recalledK043333 · VITREA2, Version 3.7 Medical Image Processing System · Vital Images, Inc. · 2004 · recalledK040305 · VITREA2 Version 3.5 · Vital Images, Inc. · 2004K032748 · VITREA2, Version 3.4 Medical Image Processing Software · Vital Images, Inc. · 2003 · recalledK023003 · Imagechecker-CT Workstation · R2 Technology, Inc. · 2002K020483 · Advantage Workstation 4.1 · GE Medical Systems · 2002 · recalledK960613 · GE Advantage Windows Review Workstation · GE Medical Systems · 1996K913770 · Advantage V.S. CT/MR Rad Diagnostic Workstation · General Electric Co. · 1991−10−50
  1. Root · 13 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. 9 generations between
  3. 3 generations backK122429 Vessel Analysis and Autoplaque for Ors VisualObject Research Systems (Ors), Inc. · 2012
  4. 2 generations backK190868 Cleerly LabsCleerly, Inc. · 2019
  5. 1 generation backK202280 Cleerly Labs v2.0Cleerly, Inc. · 2020
  6. This deviceK242338 Cleerly LABS (v2.0)Cleerly, Inc. · 2025
  7. Descendant · cites it directly · 0 of its ownK261210 Cleerly PlaqueCleerly, Inc. · 2026
  8. Descendant · cites it directly · 0 of its ownK260588 Cleerly LABSCleerly, Inc. · 2026
Show all 13 generations
  1. Root · 13 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. 12 generations backK960613 GE Advantage Windows Review WorkstationGE Medical Systems · 1996
  3. 11 generations backK020483 Advantage Workstation 4.1GE Medical Systems · 2002 · Recalled
  4. 10 generations backK023003 Imagechecker-CT WorkstationR2 Technology, Inc. · 2002
  5. 9 generations backK032748 VITREA2, Version 3.4 Medical Image Processing SoftwareVital Images, Inc. · 2003 · Recalled
  6. 8 generations backK040305 VITREA2 Version 3.5Vital Images, Inc. · 2004
  7. 7 generations backK043333 VITREA2, Version 3.7 Medical Image Processing SystemVital Images, Inc. · 2004 · Recalled
  8. 6 generations backK052632 VITREA2 Version 3.8 Medical Image Processing SoftwareVital Images, Inc. · 2005 · Recalled
  9. 5 generations backK061624 Vitrea, Version 3.9Vital Images, Inc. · 2006 · Recalled
  10. 4 generations backK071331 Vitrea Version 4.0Vital Images, Inc. · 2007 · Recalled
  11. 3 generations backK122429 Vessel Analysis and Autoplaque for Ors VisualObject Research Systems (Ors), Inc. · 2012
  12. 2 generations backK190868 Cleerly LabsCleerly, Inc. · 2019
  13. 1 generation backK202280 Cleerly Labs v2.0Cleerly, Inc. · 2020
  14. This deviceK242338 Cleerly LABS (v2.0)Cleerly, Inc. · 2025

Most influential descendants

Showing 2 of 2 · See all
  • K261210Cleerly PlaqueCleerly, Inc. · 2026 · cites it directly0descendants
  • K260588Cleerly LABSCleerly, Inc. · 2026 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−13K913770Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co.1991—
−12K960613GE Advantage Windows Review WorkstationGE Medical Systems1996—
−11K020483Advantage Workstation 4.1GE Medical Systems20022
−10K023003Imagechecker-CT WorkstationR2 Technology, Inc.2002—
−9K032748VITREA2, Version 3.4 Medical Image Processing SoftwareVital Images, Inc.20032
−8K040305VITREA2 Version 3.5Vital Images, Inc.2004—
−7K043333VITREA2, Version 3.7 Medical Image Processing SystemVital Images, Inc.20041
−6K052632VITREA2 Version 3.8 Medical Image Processing SoftwareVital Images, Inc.20052
−5K061624Vitrea, Version 3.9Vital Images, Inc.20061
−4K071331Vitrea Version 4.0Vital Images, Inc.20071
−3K122429Vessel Analysis and Autoplaque for Ors VisualObject Research Systems (Ors), Inc.2012—
−2K190868Cleerly LabsCleerly, Inc.2019—
−1K202280Cleerly Labs v2.0Cleerly, Inc.2020—
0 (this device)K242338Cleerly LABS (v2.0)Cleerly, Inc.2025—
+1K261210Cleerly PlaqueCleerly, Inc.2026—
+1K260588Cleerly LABSCleerly, Inc.2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198710
199330
199440
199530
199650
199740
199840
199940
200030
200170
200250
200330
200440
200520
200620
200720
200910

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202620
FIG. 1 — Lineage of K242338, 1991–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QIH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QIH device

  1. #1 K213998 cvi42 Auto Imaging Software Applicationscore 23.5 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K202280Cleerly Labs v2.0
Summary page 5
…agement and processing system. Product Classification Class II, § 892.2050 Product Code LLZ Submission Number K202280 Cleerly Inc. 1 1099 18th St, Suite 28…
Cleerly, Inc.2020—

Also cleared against K202280: 2 other devices →

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K261210Cleerly PlaqueCleerly, Inc.20260
K260588Cleerly LABSCleerly, Inc.20260

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 34 years and passes through 6 companies; a new generation was cleared every 11 months on median.
  • 15 of the 70 ancestors have a recall of any class.
  • Of its descendants, K261210 (Cleerly, Inc., 2026) has gone furthest, with 0 descendants of its own.
  • 2 other devices also cite its predicate K202280.

How does its category compare?

All QIH devices

QIH Automated Radiological Image Processing Software: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · QIH

94in 2025

2019: 22020: 112021: 192022: 252023: 452024: 642025: 942026 (partial year): 78
2007high 94 (2025) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QIH

150in 2025

2020: 145 days median2021: 125 days median2022: 134 days median2023: 151 days median2024: 141 days median2025: 150 days median2026 (partial year): 130 days median
2007high 151 (2023) · low 125 (2021)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · QIH

1so far in 2026, the most since 2007

2026 (partial year): 1
2007high 1 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · QIH

4in 2025

2024: 22025: 4
2007high 4 (2025) · low 0 (2007)2025

MAUDE reports naming product code QIH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20192—00
20201114500
20211912500
20222513400
20234515100
20246414102
20259415004
2026781301—

What is it indicated for?

Cleerly LABS is a web-based software application that is intended to be used by trained medical professionals as an interactive tool for viewing and analyzing cardiac computed tomography (CT) data for determining the presence and extent of coronary plaques (i.e. atherosclerosis) and stenosis in patients who underwent Coronary Computed Tomography Angiography (CCTA) for evaluation of CAD or suspected CAD. This software post processes CT images obtained…

Read the full statement (171 words)

Cleerly LABS is a web-based software application that is intended to be used by trained medical professionals as an interactive tool for viewing and analyzing cardiac computed tomography (CT) data for determining the presence and extent of coronary plaques (i.e. atherosclerosis) and stenosis in patients who underwent Coronary Computed Tomography Angiography (CCTA) for evaluation of CAD or suspected CAD. This software post processes CT images obtained using any Computed Tomography (CT) scanner. The software provides tools for the measurement and visualization of coronary arteries.

The software is not intended to replace the skill and judgment of a qualified medical practitioner and should only be used by people who have been appropriately trained in the software's functions, capabilities and limitations. Users should be aware that certain views make use of interpolated data. This is data that is created by the software based on the original data set. Interpolated data may give the appearance of healthy tissue in situations where pathology that is near or smaller than the scanning resolution may be present.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K242338: Cleerly LABS (v2.0).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K242338

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026