510(k) Report

510(k) · Cleared

Cleared

Monkey Bars Pin to Bar External Fixation System

K242452510(k) TraditionalCleared Nov 1, 202474-day reviewClass II21 CFR 888.3030

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Paragon 28, Inc. · KTT Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component

Cleared on Nov 1, 2024 as substantially equivalent to K211112 (Orthopaedic Implant Company, 2021) and 1 other predicate after a 74-day review. Its family tree reaches back 3 generations to 1983.

Decided
Nov 1, 2024
Review
74 days
Class
Class II
Product code
KTT
Recalls
None
Predicates
2

Its longest line of descent runs back 3 generations to K831576 (1983). 14 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2021: 1 other ancestor2019: 1 other ancestor2012: 1 other ancestor2010: 1 other ancestor2008: 2 other ancestors2006: 2 other ancestors1995: 1 other ancestor2005: 2 other ancestorsReference device: K212895 · Paragon 28 External Ring Fixation System · Paragon 28, Inc. · 2021K831576 · Orthofix · Electro-Biology, Inc. · 1983K955848 · Orthofix Modulsystem · Orthofix, Inc. · 1996 · recalledK113770 · Orthofix Galaxy Fixation System · Orthofix Srl · 2012 · recalled19801990200020102020
Other ancestors, by generation 1 generation back: 1 other ancestor2 generations back: 7 other ancestors3 generations back: 3 other ancestors K113770 · Orthofix Galaxy Fixation System · Orthofix Srl · 2012 · recalledK955848 · Orthofix Modulsystem · Orthofix, Inc. · 1996 · recalledK831576 · Orthofix · Electro-Biology, Inc. · 19830
  1. Root · 3 generations backK831576 OrthofixElectro-Biology, Inc. · 1983
  2. 2 generations backK955848 Orthofix ModulsystemOrthofix, Inc. · 1996 · Recalled
  3. 1 generation backK113770 Orthofix Galaxy Fixation SystemOrthofix Srl · 2012 · Recalled
  4. This deviceK242452 Monkey Bars Pin to Bar External Fixation SystemParagon 28, Inc. · 2024
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K831576OrthofixElectro-Biology, Inc.1983—
−2K955848Orthofix ModulsystemOrthofix, Inc.199623
−1K113770Orthofix Galaxy Fixation SystemOrthofix Srl201213
0 (this device)K242452Monkey Bars Pin to Bar External Fixation SystemParagon 28, Inc.2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199510
200520
200620
200820
201010
201210
201910
202110
FIG. 1 — Lineage of K242452, 1983–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KTT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KTT device

  1. #1 K242861 TrueLok Elevatescore 21.3 · 14 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K211112OIC External Fixation System
Summary page 6
…bone fragments rigidly in place. The pins are offered in various lengths and thicknesses. Primary Predicate: OIC External Fixation System (K211112) Additional Predicate: Orthofix Galaxy Fixation System (K113770) Reference Device: Monkey Rings External Fixation Syste…
Orthopaedic Implant Company2021—
*K113770Orthofix Galaxy Fixation System
Summary page 6
…various lengths and thicknesses. Primary Predicate: OIC External Fixation System (K211112) Additional Predicate: Orthofix Galaxy Fixation System (K113770) Reference Device: Monkey Rings External Fixation System (K212895) Substantial The Monkey Bars Pin to Bar Ext…
Orthofix Srl201213
†K212895Paragon 28 External Ring Fixation SystemParagon 28, Inc.2021—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 41 years and passes through 4 companies; a new generation was cleared every 12.8 years on median.
  • 4 of the 14 ancestors have a recall of any class.

How does its category compare?

All KTT devices

KTT Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · KTT

10in 2025

2007: 92008: 112009: 112010: 122011: 102012: 92013: 72014: 142015: 122016: 102017: 112018: 62019: 82020: 92021: 102022: 32023: 72024: 52025: 102026 (partial year): 5
2007high 14 (2014) · low 3 (2022)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KTT

88in 2025

2007: 55 days median2008: 73 days median2009: 94 days median2010: 148 days median2011: 157 days median2012: 140 days median2013: 87 days median2014: 129 days median2015: 60 days median2016: 142 days median2017: 184 days median2018: 149 days median2019: 110 days median2020: 200 days median2021: 83 days median2022: 25 days median2023: 29 days median2024: 90 days median2025: 88 days median2026 (partial year): 68 days median
2007high 200 (2020) · low 25 (2022)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KTT

2in 2021

2007: 22008: 12009: 22010: 12012: 42013: 72017: 12018: 142019: 32021: 22026 (partial year): 11
2007high 14 (2018) · low 0 (2011)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KTT

673in 2025

2007: 452008: 662009: 452010: 1212011: 1962012: 5272013: 8982014: 4452015: 4012016: 4002017: 4852018: 5972019: 8002020: 9422021: 9612022: 6272023: 5542024: 5232025: 673
2007high 961 (2021) · low 45 (2007)2025

MAUDE reports naming product code KTT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007955245
20081173166
20091194245
2010121481121
2011101570196
201291404527
20137877898
2014141290445
201512600401
2016101420400
2017111841485
2018614914597
201981103800
202092000942
202110832961
20223250627
20237290554
20245900523
202510880673
202656811—

What is it indicated for?

The Monkey Bars Pin to Bar External Fixation System is intended to be used in adult and pediatric patients (specifically, children and adolescents aged 2 through 21 years) for provisional fixation of open and/or unstable fractures in the lower and upper extremities and pelvis. It may also be used for temporary fixation of peri-articular or intra-articular fractures. Additionally, the device can be used on fractures where soft tissue injury or an infected fracture site may preclude the use of other fracture fixation treatments.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K242452: Monkey Bars Pin to Bar External Fixation System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K242452

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026