510(k) Report

510(k) · Cleared

Cleared

Aesculap Aicon® Series Container System

K242762510(k) TraditionalCleared May 13, 2025243-day reviewClass II21 CFR 880.6850

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Aesculap, Inc. · KCT Sterilization Wrap Containers, Trays, Cassettes & Other Accessories

Cleared on May 13, 2025 as substantially equivalent to K214041 (Aesculap, Inc., 2022) after a 243-day review. Its family tree reaches back 7 generations to 1987.

Decided
May 13, 2025
Review
243 days
Class
Class II
Product code
KCT
Recalls
None
Predicates
1

Its longest line of descent runs back 7 generations to K871202 (1987). 15 ancestors in all, the oldest K792558 (1979). No later device cites it as a predicate yet.

  1. Root · 7 generations backK871202 Flashpak Container SystemPerformance Instruments Corp. · 1987
  2. 6 generations backK022978 Steritite Container with Flashtite Valve Plate (S) & Meditray ProductsCase Medical, Inc. · 2003
  3. 5 generations backK053389 Aesculap Sterilcontainer SystemAesculap, Inc. · 2006
  4. 4 generations backK073168 Aesculap Primeline Container LTD.Aesculap, Inc. · 2008
  5. 3 generations backK112671 Sterilcontainer SystemAesculap, Ltd. · 2012
  6. 2 generations backK192056 JJ Series Container SystemAesculap, Inc. · 2020
  7. 1 generation backK214041 Aesculap AICON ContainerAesculap, Inc. · 2022
  8. This deviceK242762 Aesculap Aicon® Series Container SystemAesculap, Inc. · 2025
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K871202Flashpak Container SystemPerformance Instruments Corp.1987—
−6K022978Steritite Container with Flashtite Valve Plate (S) & Meditray ProductsCase Medical, Inc.2003—
−5K053389Aesculap Sterilcontainer SystemAesculap, Inc.2006—
−4K073168Aesculap Primeline Container LTD.Aesculap, Inc.2008—
−3K112671Sterilcontainer SystemAesculap, Ltd.2012—
−2K192056JJ Series Container SystemAesculap, Inc.2020—
−1K214041Aesculap AICON ContainerAesculap, Inc.2022—
0 (this device)K242762Aesculap Aicon® Series Container SystemAesculap, Inc.2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
197910
198510
199410
199730
200110
200410
FIG. 1 — Lineage of K242762, 1987–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KCT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KCT device

  1. #1 K214041 Aesculap AICON Containerscore 18.1 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K214041Aesculap AICON Container
Summary page 17
…CE CLASS: Class II per 21 CFR 880.6850 PREDICATE DEVICE • Primary predicate: Aicon® JJ Series Container for low temperature sterilization (K214041). • Reference Device: Aicon® JJ Series Container for PreVac Steam sterilization (K192056) DEVICE DESCRIPTION The AESCULAP Ai…
Aesculap, Inc.2022—
†K192056JJ Series Container SystemAesculap, Inc.2020—

Also cleared against K214041: 3 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 38 years and passes through 4 companies; a new generation was cleared every 2.8 years on median.
  • 1 of the 15 ancestors has a recall of any class.
  • 3 other devices also cite its predicate K214041.

How does its category compare?

All KCT devices

KCT Sterilization Wrap Containers, Trays, Cassettes & Other Accessories: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · KCT

11in 2025

2007: 32008: 62009: 62010: 122011: 62012: 102013: 82014: 112015: 152016: 122017: 102018: 152019: 182020: 142021: 182022: 112023: 102024: 82025: 112026 (partial year): 9
2007high 18 (2019) · low 3 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KCT

205in 2025

2007: 199 days median2008: 182 days median2009: 89 days median2010: 202 days median2011: 117 days median2012: 236 days median2013: 131 days median2014: 169 days median2015: 151 days median2016: 182 days median2017: 211 days median2018: 192 days median2019: 187 days median2020: 134 days median2021: 185 days median2022: 137 days median2023: 94 days median2024: 106 days median2025: 205 days median2026 (partial year): 122 days median
2007high 236 (2012) · low 89 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KCT

17in 2022

2010: 12011: 22013: 12014: 12016: 32017: 12021: 12022: 17
2007high 17 (2022) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KCT

50in 2025

2007: 22008: 82009: 52010: 32011: 32012: 22013: 62014: 52015: 62016: 162017: 32018: 222019: 152020: 662021: 262022: 82023: 302024: 182025: 50
2007high 66 (2020) · low 2 (2007)2025

MAUDE reports naming product code KCT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007319902
2008618208
200968905
20101220213
2011611723
20121023602
2013813116
20141116915
20151515106
201612182316
20171021113
201815192022
201918187015
202014134066
202118185126
202211137178
20231094030
20248106018
202511205050
202691220—

What is it indicated for?

The AESCULAP Aicon® Container is a reusable rigid sterilization container intended to be used to enclose another medical device that is to be sterilized by a healthcare provider. It is intended to allow sterilization of the enclosed device and also maintain sterility of the enclosed device during transport and until used. This container is compatible for use in the following sterilization modalities in the configurations listed below: • Ethylene Oxide…

Read the full statement (386 words)

The AESCULAP Aicon® Container is a reusable rigid sterilization container intended to be used to enclose

another medical device that is to be sterilized by a healthcare provider. It is intended to allow sterilization of the

enclosed device and also maintain sterility of the enclosed device during transport and until used. This container

is compatible for use in the following sterilization modalities in the configurations listed below:

• Ethylene Oxide (EtO)

• STERIS V-PRO maX/maX 2: Lumen, Non-Lumen, Flex

• STERIS V-PRO 60: Lumen, Non- Lumen, Flex

• STERIS V-PRO S2 Non-Lumen

• STERRAD 100NX: Standard, Express, Flex, Duo

• STERRAD NX: Standard, Advanced

• STERRAD 100S

• STERIZONE VP4

• PreVac Steam

The AESCULAP Aicon® consists of two different container styles: a solid bottom container and enhance drying

system (EDS) container.

The AESCULAP Aicon® Container is compatible with accessories such as baskets, trays, instrument

organizational accessories, holders, indicator cards, tamper evident locks, lid covers, faceplate holders, and tags.

Prevac cycles without dry times are Immediate Use Sterilization Cycles (IUSS).

The following tables identify the load configurations.

Table 1. AESCULAP Aicon® Container Lumen Configurations

Sterilization IOS Container

Configuration Compatible Lumens

Cycle Sizes

Ethylene Oxide (EtO) Full Size (2) Stainless Steel Lumens (≥3.0mm ID x ≤ 400mm L)

(130°F, 60 minute If including silicone, Three-Quarter Size (2) Stainless Steel Lumens (≥3.0mm ID x ≤ 400mm L)

exposure stainless steel, or no

50-70% RH, IOS: Half Size (2) Stainless Steel Lumens (≥3.0mm ID x ≤ 400mm L)

concentration 735mg/L)

(6) Stainless Steel Lumens (≥1mm ID x ≤ 400mm L)

Full Size

STERIS V-PRO maX (6) Stainless Steel Lumens (≥0.77mm ID x ≤ 250mm L)

Only stainless steel or (6) Stainless Steel Lumens (≥1mm ID x ≤ 400mm L)

/maX 2

no IOS: Three-Quarter Size

Lumen Cycle (6) Stainless Steel Lumens (≥0.77mm ID x ≤ 250mm L)

Half Size (12) Stainless Steel Lumens (≥1mm ID x ≤ 150mm L)

STERIS V-PRO Max/ If including silicone, Full Size Non lumened stainless steel instruments

Max 2 stainless steel, or no

Three-Quarter Size Non lumened stainless steel instruments

Non-Lumen Cycle IOS:

Half Size Non lumened stainless steel instruments

STERIS V-PRO maX / (1) Flexible endoscope with a light cord (if not integral

Only stainless steel or

maX 2 Full Size to

no IOS:

Flex Cycle endoscope) without any additional load. The flexible

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K242762: Aesculap Aicon® Series Container System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K242762

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026